메뉴 건너뛰기




Volumn 14, Issue 2, 2000, Pages 93-101

The difficult extracapsular hip fracture (including subtrochanteric)

Author keywords

[No Author keywords available]

Indexed keywords

CLASSIFICATION; ENDOPROSTHESIS; FEMUR TROCHANTERIC FRACTURE; FRACTURE FIXATION; HIP FRACTURE; HIP PROSTHESIS; HUMAN; INTRAMEDULLARY NAIL; PRIORITY JOURNAL; PROSTHESIS FAILURE; REVIEW;

EID: 0034130374     PISSN: 02680890     EISSN: None     Source Type: Journal    
DOI: 10.1054/cuor.2000.0094     Document Type: Review
Times cited : (5)

References (15)
  • 3
    • 0028271231 scopus 로고
    • Fractures of the proximal part of the femur
    • Kyle R. F. Fractures of the proximal part of the femur. J Bone Joint Surg. 76:1994;924-950.
    • (1994) J Bone Joint Surg , vol.76 , pp. 924-950
    • Kyle, R.F.1
  • 4
    • 0001536376 scopus 로고
    • Hip Fractures: II. Evaluation and treatment of intertrochanteric fractures
    • Koval K. J., Zuckerman J. D. Hip Fractures: II. Evaluation and treatment of intertrochanteric fractures. J AAOS. 2:1994;150-156.
    • (1994) J AAOS , vol.2 , pp. 150-156
    • Koval, K.J.1    Zuckerman, J.D.2
  • 5
    • 0029842184 scopus 로고    scopus 로고
    • Trochanteric fractures. Fixation failure commoner with femoral medialisation, a comparison of 101 cases
    • Parker M. J. Trochanteric fractures. Fixation failure commoner with femoral medialisation, a comparison of 101 cases. Acta Orthop Scand. 67:1996;329-332.
    • (1996) Acta Orthop Scand , vol.67 , pp. 329-332
    • Parker, M.J.1
  • 6
    • 6544243434 scopus 로고    scopus 로고
    • Extramedullary fixation of 107 subtrochanteric fractures. A randomized multicenter trial of the Medoff sliding plate versus 3 other screw-plate systems
    • Lunsjö K., Ceder L., Tidermark J. Extramedullary fixation of 107 subtrochanteric fractures. A randomized multicenter trial of the Medoff sliding plate versus 3 other screw-plate systems. Acta Orthop Scand. 70(5):1999;459-466.
    • (1999) Acta Orthop Scand , vol.705 , pp. 459-466
    • Lunsjö, K.1    Ceder, L.2    Tidermark, J.3
  • 7
    • 0031924068 scopus 로고    scopus 로고
    • Comparison of the compressive hip screw and the Medoff sliding plate for intertrochanteric fractures
    • Watson J. T., Moed B. R., Cramer K. E., Kargas D. E. Comparison of the compressive hip screw and the Medoff sliding plate for intertrochanteric fractures. Clin Orthop. 348:1998;79-86.
    • (1998) Clin Orthop , vol.348 , pp. 79-86
    • Watson, J.T.1    Moed, B.R.2    Cramer, K.E.3    Kargas, D.E.4
  • 8
    • 0031881762 scopus 로고    scopus 로고
    • RAB- plate vs Richards CHS plate for unstable trochanteric hip fractures. A randomized study of 233 patients with 1-year follow-up
    • Buciuto R., Uhlin B., Hammerby S., Hammer R. RAB- plate vs Richards CHS plate for unstable trochanteric hip fractures. A randomized study of 233 patients with 1-year follow-up. Acta Orthop Scand. 69:1998;25-28.
    • (1998) Acta Orthop Scand , vol.69 , pp. 25-28
    • Buciuto, R.1    Uhlin, B.2    Hammerby, S.3    Hammer, R.4
  • 9
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal fractures: A comparative study with the Gamma nail and compression hip screw
    • Madsen J. E., Naess L., Aune A. K., Alho A., Ekeland A., Stromsoe K. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma. 12:1998;241-248.
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3    Alho, A.4    Ekeland, A.5    Stromsoe, K.6
  • 10
    • 0031924185 scopus 로고    scopus 로고
    • Norian SRS cement augmentation in hip fracture treatment: Laboratory and initial clinical results
    • Goodman S. B., Bauer T. W., Carter D. Norian SRS cement augmentation in hip fracture treatment: laboratory and initial clinical results. Clin Orthop. 348:1998;42-50.
    • (1998) Clin Orthop , vol.348 , pp. 42-50
    • Goodman, S.B.1    Bauer, T.W.2    Carter, D.3
  • 12
    • 0032956535 scopus 로고    scopus 로고
    • A reinforced fixation device for unstable intertrochanteric fractures
    • Baixauli F., Vicent V., Baixauli E. A reinforced fixation device for unstable intertrochanteric fractures. Clin Orthop. 361:1999;205-215.
    • (1999) Clin Orthop , vol.361 , pp. 205-215
    • Baixauli, F.1    Vicent, V.2    Baixauli, E.3
  • 13
    • 0024547454 scopus 로고
    • Subtrochanteric fractures of the femur: Results of treatment with the 95 degrees condylar blade-plate
    • Kinast C., Bolhofner B. R., Mast J. W., Ganz R. Subtrochanteric fractures of the femur: results of treatment with the 95 degrees condylar blade-plate. Clin Orthop. 238:1989;122-130.
    • (1989) Clin Orthop , vol.238 , pp. 122-130
    • Kinast, C.1    Bolhofner, B.R.2    Mast, J.W.3    Ganz, R.4
  • 14
    • 0030013059 scopus 로고    scopus 로고
    • Gamma versus DHS nailing for extracapsular femoral fractures. Meta-analysis of ten randomised trials
    • Parker M. J., Pryor G. A. Gamma versus DHS nailing for extracapsular femoral fractures. Meta-analysis of ten randomised trials. Int Orthop. 20:1996;163-168.
    • (1996) Int Orthop , vol.20 , pp. 163-168
    • Parker, M.J.1    Pryor, G.A.2
  • 15
    • 0029201172 scopus 로고
    • Treatment of unstable peritrochanteric fractures in elderly patients with a compression hip screw or with the the Vandeputte (VDP) endoprothesis: A prospective randomised study
    • Staepperts K. H., Deldycke J., Broos P. L. O., States F. F. G. M., Rommens P. M., Claes P. Treatment of unstable peritrochanteric fractures in elderly patients with a compression hip screw or with the the Vandeputte (VDP) endoprothesis: a prospective randomised study. J Orthop Trauma. 9:1995;292-297.
    • (1995) J Orthop Trauma , vol.9 , pp. 292-297
    • Staepperts, K.H.1    Deldycke, J.2    Broos, P.L.O.3    States, F.F.G.M.4    Rommens, P.M.5    Claes, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.