메뉴 건너뛰기




Volumn 38, Issue 3, 2000, Pages 200-204

Comparison of two systems for rigidly connecting 2.0-mm bone screws to an implantable device: In vitro stability testing

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE SCREW; IMPLANT; INTERMETHOD COMPARISON; MANDIBLE RECONSTRUCTION; SHEAR STRESS;

EID: 0034130160     PISSN: 02664356     EISSN: None     Source Type: Journal    
DOI: 10.1054/bjom.1999.0177     Document Type: Article
Times cited : (9)

References (11)
  • 1
    • 0023546198 scopus 로고
    • Osseointegration of bone implants. A review of an alternative mode of fixation
    • Albrektsson T., Albrektsson B. Osseointegration of bone implants. A review of an alternative mode of fixation. Acta Orthop Scand. 58:1987;567-577.
    • (1987) Acta Orthop Scand , vol.58 , pp. 567-577
    • Albrektsson, T.1    Albrektsson, B.2
  • 2
    • 0029115865 scopus 로고
    • Evaluation of temporomandibular joint prostheses. Review of the literature from 1946 to 1994 and implications for future prosthesis designs
    • van Loon J-P., de Bont L. G. M., Boering G. Evaluation of temporomandibular joint prostheses. Review of the literature from 1946 to 1994 and implications for future prosthesis designs. J Oral Maxillofac Surg. 53:1995;984-996.
    • (1995) J Oral Maxillofac Surg , vol.53 , pp. 984-996
    • Van Loon, J.-P.1    De Bont, L.G.M.2    Boering, G.3
  • 3
    • 0030337727 scopus 로고    scopus 로고
    • Fixation with reconstruction plates under critical conditions: The role of screw characteristics
    • Soderholm A. L., Rahn B. A., Skutnabb K., Lindqvist C. Fixation with reconstruction plates under critical conditions: the role of screw characteristics. Int J Oral Maxillofac Surg. 25:1996;469-473.
    • (1996) Int J Oral Maxillofac Surg. , vol.25 , pp. 469-473
    • Soderholm, A.L.1    Rahn, B.A.2    Skutnabb, K.3    Lindqvist, C.4
  • 4
    • 0016715584 scopus 로고
    • The reaction of cortical bone to compression by screw threads
    • Schatzker J., Horne J. G., Summer-Smith G. S. The reaction of cortical bone to compression by screw threads. Clin Orthop Rel Res. 111:1975;263-265.
    • (1975) Clin Orthop Rel Res , vol.111 , pp. 263-265
    • Schatzker, J.1    Horne, J.G.2    Summer-Smith, G.S.3
  • 5
    • 0028032268 scopus 로고
    • Cortical porosis under plates. Reaction to unloading or to necrosis?
    • Uhthoff H. K., Boisvert D., Finnegan M. Cortical porosis under plates. Reaction to unloading or to necrosis? J Bone Joint Surg. 76A:1994;1507-1512.
    • (1994) J Bone Joint Surg , vol.76 , pp. 1507-1512
    • Uhthoff, H.K.1    Boisvert, D.2    Finnegan, M.3
  • 6
    • 0020963995 scopus 로고
    • Mandibular reconstruction using a special plate. Animal experiments and clinical application
    • Schmoker R. R. Mandibular reconstruction using a special plate. Animal experiments and clinical application. J Maxillofac Surg. 11:1983;99-106.
    • (1983) J Maxillofac Surg , vol.11 , pp. 99-106
    • Schmoker, R.R.1
  • 8
    • 0023390181 scopus 로고
    • Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: Bridging of defects
    • Raveh J., Sutter F., Hellem S. Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: bridging of defects. Otolaryngol Clin North Am. 20:1987;535-558.
    • (1987) Otolaryngol Clin North Am , vol.20 , pp. 535-558
    • Raveh, J.1    Sutter, F.2    Hellem, S.3
  • 9
    • 0024059998 scopus 로고
    • Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: Biomechanical aspects
    • Sutter F., Raveh J. Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects. Int J Oral Maxillofac Surg. 17:1988;267-274.
    • (1988) Int J Oral Maxillofac Surg , vol.17 , pp. 267-274
    • Sutter, F.1    Raveh, J.2
  • 10
    • 0032223681 scopus 로고    scopus 로고
    • Loading of a unilateral temporomandibular joint prosthesis. A three-dimensional mathematical study
    • van Loon J-P., Otten E., Falkenström C. H., de Bont L. G. M., Verkerke G. J. Loading of a unilateral temporomandibular joint prosthesis. A three-dimensional mathematical study. J Dent Res. 77:1998;1939-1947.
    • (1998) J Dent Res , vol.77 , pp. 1939-1947
    • Van Loon, J.-P.1    Otten, E.2    Falkenström, C.H.3    De Bont, L.G.M.4    Verkerke, G.J.5
  • 11
    • 0031913789 scopus 로고    scopus 로고
    • Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws
    • Heidemann W., Gerlach K. L., Grobel K-H., Kollner H-G. Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws. J Craniomaxillofac Surg. 26:1998;50-55.
    • (1998) J Craniomaxillofac Surg , vol.26 , pp. 50-55
    • Heidemann, W.1    Gerlach, K.L.2    Grobel, K.-H.3    Kollner, H.-G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.