메뉴 건너뛰기




Volumn 15, Issue 1, 2000, Pages 5-11

Nonpulmonary organ failure and outcome in children treated with high- frequency oscillatory ventilation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; CHILD; CONTROLLED STUDY; DISEASE COURSE; FEMALE; GAS EXCHANGE; HEART FAILURE; HUMAN; INFANT; LUNG INSUFFICIENCY; MAJOR CLINICAL STUDY; MALE; MORTALITY; MULTIPLE ORGAN FAILURE; OXYGENATION; RETROSPECTIVE STUDY; WEANING;

EID: 0034122942     PISSN: 08839441     EISSN: None     Source Type: Journal    
DOI: 10.1053/jcrc.2000.0150005     Document Type: Article
Times cited : (16)

References (23)
  • 1
    • 0029083676 scopus 로고
    • Predicting death in pediatric patients with acute respiratory failure
    • OD Timmons PL Havens JC Fackler Predicting death in pediatric patients with acute respiratory failure Chest 108 1995 789 797
    • (1995) Chest , vol.108 , pp. 789-797
    • Timmons, OD1    Havens, PL2    Fackler, JC3
  • 2
    • 0031942649 scopus 로고    scopus 로고
    • Ventilator-induced lung injury: Lessons from experimental studies
    • D Dreyfuss G Saumon Ventilator-induced lung injury: Lessons from experimental studies Am J Respir Crit Care Med 157 1998 294 323
    • (1998) Am J Respir Crit Care Med , vol.157 , pp. 294-323
    • Dreyfuss, D1    Saumon, G2
  • 3
    • 0027948495 scopus 로고
    • Low mortality rate in adult respiratory distress syndrome using low-volume, pressure-limited ventilation with permissive hypercapnia: A prospective study
    • KG Hickling J Walsh S Henderson Low mortality rate in adult respiratory distress syndrome using low-volume, pressure-limited ventilation with permissive hypercapnia: A prospective study Crit Care Med 22 1994 1568 1578
    • (1994) Crit Care Med , vol.22 , pp. 1568-1578
    • Hickling, KG1    Walsh, J2    Henderson, S3
  • 4
    • 0028798336 scopus 로고
    • Improved survival of patients with acute respiratory distress syndrome (ARDS): 1983-1993
    • JA Milberg DR Davis KP Steinberg Improved survival of patients with acute respiratory distress syndrome (ARDS): 1983-1993 JAMA 273 1995 306 309
    • (1995) JAMA , vol.273 , pp. 306-309
    • Milberg, JA1    Davis, DR2    Steinberg, KP3
  • 5
    • 0032484956 scopus 로고    scopus 로고
    • Effect of a protective-ventilation strategy on mortality in acute respiratory distress syndrome
    • MB Amato CS Barbas DM Madeiros Effect of a protective-ventilation strategy on mortality in acute respiratory distress syndrome N Engl J Med 338 1998 347 354
    • (1998) N Engl J Med , vol.338 , pp. 347-354
    • Amato, MB1    Barbas, CS2    Madeiros, DM3
  • 6
    • 0026580306 scopus 로고
    • Prospective randomized comparison of high frequency oscillatory and conventional ventilation in respiratory distress syndrome
    • RH Clark DR Gerstmann DM Null Jr Prospective randomized comparison of high frequency oscillatory and conventional ventilation in respiratory distress syndrome Pediatrics 89 1992 5 12
    • (1992) Pediatrics , vol.89 , pp. 5-12
    • Clark, RH1    Gerstmann, DR2    Null, DM3
  • 7
    • 0027509646 scopus 로고
    • Randomized study of high-frequency oscillatory ventilation in infants with severe respiratory distress syndrome
    • HiFO Study Group Randomized study of high-frequency oscillatory ventilation in infants with severe respiratory distress syndrome J Pediatr 122 1993 609 619
    • (1993) J Pediatr , vol.122 , pp. 609-619
    • HiFO Study Group1
  • 8
    • 0028085524 scopus 로고
    • Reduction in lung injury after combined surfactant and high frequency ventilation
    • JG Jackson WE Truog TA Standaert Reduction in lung injury after combined surfactant and high frequency ventilation Am J Respir Crit Care Med 150 1994 534 539
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 534-539
    • Jackson, JG1    Truog, WE2    Standaert, TA3
  • 9
    • 10544236909 scopus 로고    scopus 로고
    • The Provo early high-frequency oscillatory ventilation trial: Improved pulmonary and clinical outcome in respiratory distress syndrome
    • Dr Gerstmann SD Minton RA Stoddard The Provo early high-frequency oscillatory ventilation trial: Improved pulmonary and clinical outcome in respiratory distress syndrome Pediatrics 98 1996 1044 1057
    • (1996) Pediatrics , vol.98 , pp. 1044-1057
    • Gerstmann, Dr1    Minton, SD2    Stoddard, RA3
  • 10
    • 0020538627 scopus 로고
    • Comparison of conventional and high-frequency ventilation: Oxygenation and lung pathology
    • PP Hamilton A Onayemi JA Smyth Comparison of conventional and high-frequency ventilation: Oxygenation and lung pathology J Appl Physiol 55 1983 131 138
    • (1983) J Appl Physiol , vol.55 , pp. 131-138
    • Hamilton, PP1    Onayemi, A2    Smyth, JA3
  • 11
    • 0027418672 scopus 로고
    • High-frequency oscillatory ventilation in pediatric respiratory failure
    • JH Arnold RD Truog JE Thompson High-frequency oscillatory ventilation in pediatric respiratory failure Crit Care Med 21 1993 272 278
    • (1993) Crit Care Med , vol.21 , pp. 272-278
    • Arnold, JH1    Truog, RD2    Thompson, JE3
  • 12
    • 0027435436 scopus 로고
    • High frequency ventilation for acute pediatric respiratory failure
    • RB Rosenberg CW Broner KJ Peters High frequency ventilation for acute pediatric respiratory failure Chest 104 1993 1216 1221
    • (1993) Chest , vol.104 , pp. 1216-1221
    • Rosenberg, RB1    Broner, CW2    Peters, KJ3
  • 13
    • 0027949271 scopus 로고
    • Prospective randomized comparison of high-frequency oscillatory and conventional mechanical ventilation in pediatric respiratory failure
    • JH Arnold JH Hanson LO Toro-Figuero Prospective randomized comparison of high-frequency oscillatory and conventional mechanical ventilation in pediatric respiratory failure Crit Care Med 22 1994 1530 1539
    • (1994) Crit Care Med , vol.22 , pp. 1530-1539
    • Arnold, JH1    Hanson, JH2    Toro-Figuero, LO3
  • 14
    • 0029838134 scopus 로고    scopus 로고
    • Predicting outcome in children with severe acute respiratory failure treated with high-frequency ventilation
    • AP Sarnaik KL Meert MD Pappas Predicting outcome in children with severe acute respiratory failure treated with high-frequency ventilation Crit Care Med 24 1996 1396 1402
    • (1996) Crit Care Med , vol.24 , pp. 1396-1402
    • Sarnaik, AP1    Meert, KL2    Pappas, MD3
  • 15
    • 0028031459 scopus 로고
    • Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung
    • M Sugiura PR McCulloch S Wren Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung J Appl Physiol 77 1994 1355 1365
    • (1994) J Appl Physiol , vol.77 , pp. 1355-1365
    • Sugiura, M1    McCulloch, PR2    Wren, S3
  • 16
    • 0028148259 scopus 로고
    • Inflammatory chemical mediators during conventional mechanical ventilation and during high frequency oscillatory ventilation
    • Y Imai T Kawano K Miyasaka Inflammatory chemical mediators during conventional mechanical ventilation and during high frequency oscillatory ventilation Am J Respir Crit Care Med 150 1994 1550 1554
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 1550-1554
    • Imai, Y1    Kawano, T2    Miyasaka, K3
  • 17
    • 0030744192 scopus 로고    scopus 로고
    • Intraalveolar expression of tumor necrosis factor-α gene during conventional and high-frequency ventilation
    • M Takata J Abe H Tanaka Intraalveolar expression of tumor necrosis factor-α gene during conventional and high-frequency ventilation Am J Respir Crit Care Med 156 1997 272 279
    • (1997) Am J Respir Crit Care Med , vol.156 , pp. 272-279
    • Takata, M1    Abe, J2    Tanaka, H3
  • 18
    • 0028106437 scopus 로고
    • Sustained inflations improve respiratory compliance during high-frequency oscillatory ventilation but not during large tidal volume positive-pressure ventilation in rabbits
    • DM Bond J McAloon AB Froese Sustained inflations improve respiratory compliance during high-frequency oscillatory ventilation but not during large tidal volume positive-pressure ventilation in rabbits Crit Care Med 22 1994 1269 1277
    • (1994) Crit Care Med , vol.22 , pp. 1269-1277
    • Bond, DM1    McAloon, J2    Froese, AB3
  • 19
    • 0028220086 scopus 로고
    • Role of high frequency ventilation in surfactant-depleted lung injury as measured by granulocytes
    • T Matsuoka T Kawano K Miyasaka Role of high frequency ventilation in surfactant-depleted lung injury as measured by granulocytes J Appl Physiol 76 1994 539 544
    • (1994) J Appl Physiol , vol.76 , pp. 539-544
    • Matsuoka, T1    Kawano, T2    Miyasaka, K3
  • 20
    • 0031968324 scopus 로고    scopus 로고
    • Acute lung injury in the medical ICU: Comorbid conditions, age, etiology, and hospital outcomes
    • MD Zilberberg SK Epstein Acute lung injury in the medical ICU: Comorbid conditions, age, etiology, and hospital outcomes Am J Respir Crit Care Med 157 1998 1159 1164
    • (1998) Am J Respir Crit Care Med , vol.157 , pp. 1159-1164
    • Zilberberg, MD1    Epstein, SK2
  • 21
    • 0028888644 scopus 로고
    • Clinical risks for the development of the acute respiratory distress syndrome
    • LD Hudson JA Milberg D Anardi Clinical risks for the development of the acute respiratory distress syndrome Am J Respir Crit Care Med 151 1995 293 301
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 293-301
    • Hudson, LD1    Milberg, JA2    Anardi, D3
  • 22
    • 0023618699 scopus 로고
    • Mortality associated with multiple organ system failure and sepsis in pediatric intensive care unit
    • JD Wilkinson MM Pollack NL Glass Mortality associated with multiple organ system failure and sepsis in pediatric intensive care unit J Pediatr 111 1987 324 328
    • (1987) J Pediatr , vol.111 , pp. 324-328
    • Wilkinson, JD1    Pollack, MM2    Glass, NL3
  • 23
    • 0026261675 scopus 로고
    • High-frequency jet ventilation improves cardiac function after the Fontan procedure
    • JN Meliones EL Bove MK Dekeon High-frequency jet ventilation improves cardiac function after the Fontan procedure Circ 84 suppl III 1991 364 368
    • (1991) Circ , vol.84 , Issue.suppl III , pp. 364-368
    • Meliones, JN1    Bove, EL2    Dekeon, MK3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.