메뉴 건너뛰기




Volumn 375, Issue , 2000, Pages 30-42

Percutaneous treatment of peritrochanteric fractures using the Gamma nail

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE PLATE; DEBRIDEMENT; FEMUR TROCHANTERIC FRACTURE; FRACTURE FIXATION; FRACTURE HEALING; HIP ARTHROPLASTY; HUMAN; IMPLANTATION; INTRAMEDULLARY NAILING; PRIORITY JOURNAL; SURGICAL TECHNIQUE; WEIGHT BEARING;

EID: 0034120661     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-200006000-00005     Document Type: Article
Times cited : (56)

References (59)
  • 1
    • 0030025686 scopus 로고    scopus 로고
    • Complications and technical problems with the gamma nail
    • Albareda J, Laderiga A, Palanca D, et al: Complications and technical problems with the gamma nail. Int Orthop 20:47-50, 1996.
    • (1996) Int Orthop , vol.20 , pp. 47-50
    • Albareda, J.1    Laderiga, A.2    Palanca, D.3
  • 2
    • 0028307825 scopus 로고
    • Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients
    • Aune AK, Ekeland A, Odegaard B, et al: Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Acta Orthop Scand 65:127-130, 1994.
    • (1994) Acta Orthop Scand , vol.65 , pp. 127-130
    • Aune, A.K.1    Ekeland, A.2    Odegaard, B.3
  • 3
    • 0025425425 scopus 로고
    • The fixation and prognosis of trochanteric fractures. A randomized prospective controlled trial
    • Bannister GC, Gibson AG, Ackroyd CE, Newman JH: The fixation and prognosis of trochanteric fractures. A randomized prospective controlled trial. Clin Orthop 254:242-246, 1990.
    • (1990) Clin Orthop , vol.254 , pp. 242-246
    • Bannister, G.C.1    Gibson, A.G.2    Ackroyd, C.E.3    Newman, J.H.4
  • 4
    • 0141743013 scopus 로고
    • Jewett nail plate or AO dynamic hip screw for trochanteric fractures? A randomised prospective controlled trial
    • Bannister GC, Gibson AGF: Jewett nail plate or AO dynamic hip screw for trochanteric fractures? A randomised prospective controlled trial. J Bone Joint Surg 65B:218, 1983.
    • (1983) J Bone Joint Surg , vol.65 B , pp. 218
    • Bannister, G.C.1    Gibson, A.G.F.2
  • 5
    • 0001917308 scopus 로고
    • Gamma nail versus CHS in intertrochanteric and subtrochanteric femoral fractures: A preliminary report of a prospective randomized study
    • Benum P, Grontvedt T, Braten M, et al: Gamma nail versus CHS in intertrochanteric and subtrochanteric femoral fractures: A preliminary report of a prospective randomized study. Acta Orthop Scand 63 (Suppl 247):7-8, 1992.
    • (1992) Acta Orthop Scand , vol.63 , Issue.247 SUPPL. , pp. 7-8
    • Benum, P.1    Grontvedt, T.2    Braten, M.3
  • 6
    • 0026343448 scopus 로고
    • Results of the multicentric Italian experience on the Gamma nail: A report on 648 cases
    • published erratum appears in Orthopedics 15:545, 1992
    • Boriani S, Bettelli G, Zmerly H, et al: Results of the multicentric Italian experience on the Gamma nail: A report on 648 cases [published erratum appears in Orthopedics 15:545, 1992]. Orthopedics 14:1307-1314, 1991.
    • (1991) Orthopedics , vol.14 , pp. 1307-1314
    • Boriani, S.1    Bettelli, G.2    Zmerly, H.3
  • 7
    • 8944231646 scopus 로고    scopus 로고
    • A technical report reviewing the use of the 11-mm Gamma nail: Interoperative femur fracture incidence
    • Boriani S, De lure F, Campanacci L, et al: A technical report reviewing the use of the 11-mm Gamma nail: Interoperative femur fracture incidence. Orthopedics 19:597-600, 1996.
    • (1996) Orthopedics , vol.19 , pp. 597-600
    • Boriani, S.1    De Lure, F.2    Campanacci, L.3
  • 8
    • 0026090325 scopus 로고
    • Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw
    • Bridle SH, Patel AD, Bircher M, Calvert PT: Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg 73B:330-334, 1991.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 330-334
    • Bridle, S.H.1    Patel, A.D.2    Bircher, M.3    Calvert, P.T.4
  • 9
    • 0141519992 scopus 로고
    • An experimental study on the use of nails and bolt screws in the fixation of fractures of the femoral neck
    • Brodetti A: An experimental study on the use of nails and bolt screws in the fixation of fractures of the femoral neck. Acta Orthop Scand 31:247-271, 1961.
    • (1961) Acta Orthop Scand , vol.31 , pp. 247-271
    • Brodetti, A.1
  • 10
    • 0018859794 scopus 로고
    • Mechanical property distributions in the cancellous bone of the human proximal femur
    • Brown TD, Ferguson ABJ: Mechanical property distributions in the cancellous bone of the human proximal femur. Acta Orthop Scand 51:429-437, 1980.
    • (1980) Acta Orthop Scand , vol.51 , pp. 429-437
    • Brown, T.D.1    Ferguson, A.B.J.2
  • 11
    • 0026518675 scopus 로고
    • The Gamma nail - A significant advance or a passing fashion?
    • Editorial
    • Calvert PT: The Gamma nail - A significant advance or a passing fashion? J Bone Joint Surg 74B:329-331, 1992. Editorial.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 329-331
    • Calvert, P.T.1
  • 12
    • 0028082060 scopus 로고
    • Proximal femoral fractures: A biomechanical study to compare intramedullary and extramedullary fixation
    • Curtis MJ, Jinnah RH, Wilson V, Cunningham BW: Proximal femoral fractures: A biomechanical study to compare intramedullary and extramedullary fixation. Injury 25:99-104, 1994.
    • (1994) Injury , vol.25 , pp. 99-104
    • Curtis, M.J.1    Jinnah, R.H.2    Wilson, V.3    Cunningham, B.W.4
  • 13
    • 0026335169 scopus 로고
    • Peritrochanteric fractures treated with the Gamma nail: Technique and report of early results
    • Davis J, Harris MB, Duval M, D'Ambrosia R: Peritrochanteric fractures treated with the Gamma nail: Technique and report of early results. Orthopedics 14:939-942, 1991.
    • (1991) Orthopedics , vol.14 , pp. 939-942
    • Davis, J.1    Harris, M.B.2    Duval, M.3    D'Ambrosia, R.4
  • 14
    • 0025034792 scopus 로고
    • Intertrochanteric femoral fractures. Mechanical failure after internal fixation
    • Davis TR, Sher JL, Horsman A, et al: Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg 72B:26-31, 1990.
    • (1990) J Bone Joint Surg , vol.72 B , pp. 26-31
    • Davis, T.R.1    Sher, J.L.2    Horsman, A.3
  • 15
    • 0015694271 scopus 로고
    • The unstable intertrochanteric fracture
    • Dimon JH: The unstable intertrochanteric fracture. Clin Orthop 92:100-107, 1973.
    • (1973) Clin Orthop , vol.92 , pp. 100-107
    • Dimon, J.H.1
  • 16
    • 0018687999 scopus 로고
    • Intertrochanteric fractures of the hip treated with the hip compression screw: Analysis of problems
    • Doherty JHJ, Lyden JP: Intertrochanteric fractures of the hip treated with the hip compression screw: Analysis of problems. Clin Orthop 141:184-187, 1979.
    • (1979) Clin Orthop , vol.141 , pp. 184-187
    • Doherty, J.H.J.1    Lyden, J.P.2
  • 17
    • 0000136393 scopus 로고
    • The role of anesthesia in surgical mortality
    • Dripps RD, Lamont A, Eckenhoff JE: The role of anesthesia in surgical mortality. JAMA 178:261-266, 1961.
    • (1961) JAMA , vol.178 , pp. 261-266
    • Dripps, R.D.1    Lamont, A.2    Eckenhoff, J.E.3
  • 18
    • 0016085724 scopus 로고
    • Biomechanical characteristics and surgical management of subtrochanteric fractures
    • Fielding JW, Cochran GV, Zickel RE: Biomechanical characteristics and surgical management of subtrochanteric fractures. Orthop Clin North Am 5:629-650, 1974.
    • (1974) Orthop Clin North Am , vol.5 , pp. 629-650
    • Fielding, J.W.1    Cochran, G.V.2    Zickel, R.E.3
  • 19
    • 0025069811 scopus 로고
    • The stability of intertrochanteric fractures treated with a sliding screw-plate
    • Flores EA, Harrington IJ, Heller M: The stability of intertrochanteric fractures treated with a sliding screw-plate. J Bone Joint Surg 72B:37-40, 1990.
    • (1990) J Bone Joint Surg , vol.72 B , pp. 37-40
    • Flores, E.A.1    Harrington, I.J.2    Heller, M.3
  • 20
    • 0002910992 scopus 로고
    • Swedish experience of the first 209 randomized patients with Gamma nail vs. screw-plate
    • Fornander P, Thorngren K-G, Tornqvist H, Ahrengart L, Lindgren U: Swedish experience of the first 209 randomized patients with Gamma nail vs. screw-plate. Acta Orthop Scand 63 (Suppl 248):90, 1992.
    • (1992) Acta Orthop Scand , vol.63 , Issue.248 SUPPL. , pp. 90
    • Fornander, P.1    Thorngren, K.-G.2    Tornqvist, H.3    Ahrengart, L.4    Lindgren, U.5
  • 21
    • 0028537387 scopus 로고
    • Gammanagelosteosynthese per-und subtrochanterer femurfrakturen. 4-jahres-erfahrungen und ihre konsequenzen fur die weitere implantatentwicklung
    • Friedl W, Colombo-Benkmann M, Dockter S, Machens HG, Mieck U: [Gamma nail osteosynthesis of per-and subtrochanteric femoral fractures. 4 years experiences and their consequences for further implant development]. Gammanagelosteosynthese per-und subtrochanterer femurfrakturen. 4-jahres-erfahrungen und ihre konsequenzen fur die weitere implantatentwicklung. Chirurg 65:953-963, 1994.
    • (1994) Chirurg , vol.65 , pp. 953-963
    • Friedl, W.1    Colombo-Benkmann, M.2    Dockter, S.3    Machens, H.G.4    Mieck, U.5
  • 22
    • 0028528650 scopus 로고
    • A prospective comparative study of the compression hip screw and the gamma nail
    • Goldhagen PR, O'Connor DR, Schwarze D, Schwanz E: A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma 8:367-372, 1994.
    • (1994) J Orthop Trauma , vol.8 , pp. 367-372
    • Goldhagen, P.R.1    O'Connor, D.R.2    Schwarze, D.3    Schwanz, E.4
  • 23
    • 0026506867 scopus 로고
    • Der gamma-nagel als belastungsstabile alternative zur DHS bei der instabilen proximalen femurfraktur des alten menschen
    • Guyer P, Landolt M, Eberle C, Keller H: [The gamma-nail as a resilient alternative to the dynamic hip screw in unstable proximal femoral fractures in the elderly]. Der Gamma-Nagel als belastungsstabile alternative zur DHS bei der instabilen proximalen femurfraktur des alten menschen. Helv Chir Acta 58:697-703, 1992.
    • (1992) Helv Chir Acta , vol.58 , pp. 697-703
    • Guyer, P.1    Landolt, M.2    Eberle, C.3    Keller, H.4
  • 24
    • 0026544624 scopus 로고
    • The Gamma nail for peritrochanteric fractures
    • Halder SC: The Gamma nail for peritrochanteric fractures. J Bone Joint Surg 74B:340-344, 1992.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 340-344
    • Halder, S.C.1
  • 25
    • 0031808886 scopus 로고    scopus 로고
    • Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients
    • Hardy DC, Descamps PY, Krallis P, et al: Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg 80A:618-630, 1998.
    • (1998) J Bone Joint Surg , vol.80 A , pp. 618-630
    • Hardy, D.C.1    Descamps, P.Y.2    Krallis, P.3
  • 26
    • 0030094502 scopus 로고    scopus 로고
    • Intertrochanteric fractures of the femur: A randomized prospective comparison of the Gamma nail and the Ambi hip screw
    • Hoffman CW, Lynskey TG: Intertrochanteric fractures of the femur: A randomized prospective comparison of the Gamma nail and the Ambi hip screw. Aust N Z J Surg 66:151-155, 1996.
    • (1996) Aust N Z J Surg , vol.66 , pp. 151-155
    • Hoffman, C.W.1    Lynskey, T.G.2
  • 27
    • 0005731827 scopus 로고
    • Gamma nail versus DHS in the treatment of trochanteric and subtrochanteric fractures
    • Hogh J, Andersen K, Duus B, et al: Gamma nail versus DHS in the treatment of trochanteric and subtrochanteric fractures. Acta Orthop Scand 63 (Suppl 248):86-87, 1992.
    • (1992) Acta Orthop Scand , vol.63 , Issue.248 SUPPL. , pp. 86-87
    • Hogh, J.1    Andersen, K.2    Duus, B.3
  • 28
    • 0018865818 scopus 로고
    • Internal fixation of intertrochanteric hip fractures: A clinical and biomechanical study
    • Jacobs RR, McClain O, Armstrong HJ: Internal fixation of intertrochanteric hip fractures: A clinical and biomechanical study. Clin Orthop 146:62-70, 1980.
    • (1980) Clin Orthop , vol.146 , pp. 62-70
    • Jacobs, R.R.1    McClain, O.2    Armstrong, H.J.3
  • 29
    • 0018188643 scopus 로고
    • Unstable trochanteric fractures treated with the sliding screw-plate system. A biomechanical study of unstable trochanteric fractures. III
    • Jensen JS, Tondevold E, Mossing N: Unstable trochanteric fractures treated with the sliding screw-plate system. A biomechanical study of unstable trochanteric fractures. III. Acta Orthop Scand 49:392-397, 1978.
    • (1978) Acta Orthop Scand , vol.49 , pp. 392-397
    • Jensen, J.S.1    Tondevold, E.2    Mossing, N.3
  • 30
    • 0007411956 scopus 로고
    • One-piece angle nail plate for trochanteric fractures
    • Jewett EL: One-piece angle nail plate for trochanteric fractures. J Bone Joint Surg 23:803-810, 1941.
    • (1941) J Bone Joint Surg , vol.23 , pp. 803-810
    • Jewett, E.L.1
  • 31
    • 0019164767 scopus 로고
    • Biomechanical analysis of the sliding characteristics of compression hip screws
    • Kyle RF, Wright TM, Burstein AH: Biomechanical analysis of the sliding characteristics of compression hip screws. J Bone Joint Surg 62A: 1308-1314, 1980.
    • (1980) J Bone Joint Surg , vol.62 A , pp. 1308-1314
    • Kyle, R.F.1    Wright, T.M.2    Burstein, A.H.3
  • 32
    • 0028920150 scopus 로고
    • Prevention of fracture at the distal locking site of the gamma nail. A biomechanical study
    • Lacroix H, Arwert H, Snijders CJ, Fontijne WP: Prevention of fracture at the distal locking site of the gamma nail. A biomechanical study. J Bone Joint Surg 77B:274-276, 1995.
    • (1995) J Bone Joint Surg , vol.77 B , pp. 274-276
    • Lacroix, H.1    Arwert, H.2    Snijders, C.J.3    Fontijne, W.P.4
  • 33
    • 0030049044 scopus 로고    scopus 로고
    • Multicenter trial of modified Gamma nail in East Asia
    • Leung KS, Chen CM, So WS, et al: Multicenter trial of modified Gamma nail in East Asia. Clin Orthop 323:146-154, 1996.
    • (1996) Clin Orthop , vol.323 , pp. 146-154
    • Leung, K.S.1    Chen, C.M.2    So, W.S.3
  • 34
    • 0026504845 scopus 로고
    • Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients
    • Leung KS, So WS, Shen WY, Hui PW: Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg 748:345-351, 1992.
    • (1992) J Bone Joint Surg , vol.748 , pp. 345-351
    • Leung, K.S.1    So, W.S.2    Shen, W.Y.3    Hui, P.W.4
  • 35
    • 0026344705 scopus 로고
    • Early experience with the gamma interlocking nail for peritrochanteric fractures of the proximal femur
    • Lindsey RW, Teal P, Probe RA, et al: Early experience with the gamma interlocking nail for peritrochanteric fractures of the proximal femur. J Trauma 31:1649-1658, 1991.
    • (1991) J Trauma , vol.31 , pp. 1649-1658
    • Lindsey, R.W.1    Teal, P.2    Probe, R.A.3
  • 36
    • 0031754784 scopus 로고    scopus 로고
    • Forces required to initiate sliding in second-generation intramedullary nails
    • Loch DA, Kyle RF, Bechtold JE, et al: Forces required to initiate sliding in second-generation intramedullary nails. J Bone Joint Surg 80A: 1626-1631, 1998.
    • (1998) J Bone Joint Surg , vol.80 A , pp. 1626-1631
    • Loch, D.A.1    Kyle, R.F.2    Bechtold, J.E.3
  • 37
    • 0030032703 scopus 로고    scopus 로고
    • The prevention of complications with the Gamma locking nail
    • Lyddon DWJ: The prevention of complications with the Gamma Locking Nail [see comments]. Am J Orthop 25:357-363, 1996.
    • (1996) Am J Orthop , vol.25 , pp. 357-363
    • Lyddon, D.W.J.1
  • 38
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw
    • Madsen JE, Naess L, Aune AK, et al: Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241-248, 1998.
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3
  • 39
    • 0026781425 scopus 로고
    • Cracking of the femoral shaft by the gamma nail
    • Mahaisavariya B, Laupattarakasem W: Cracking of the femoral shaft by the gamma nail. Injury 23:493-495, 1992.
    • (1992) Injury , vol.23 , pp. 493-495
    • Mahaisavariya, B.1    Laupattarakasem, W.2
  • 40
    • 0028098721 scopus 로고
    • Biomechanical analysis of the Gamma nail and sliding hip screw
    • Mahomed N, Harrington I, Kellam J, et al: Biomechanical analysis of the Gamma nail and sliding hip screw. Clin Orthop 304:280-288, 1994.
    • (1994) Clin Orthop , vol.304 , pp. 280-288
    • Mahomed, N.1    Harrington, I.2    Kellam, J.3
  • 41
    • 0022979967 scopus 로고
    • Malassembly of the sliding screw-plate device
    • Manoli A: Malassembly of the sliding screw-plate device. J Trauma 26:916-922, 1986.
    • (1986) J Trauma , vol.26 , pp. 916-922
    • Manoli, A.1
  • 42
    • 0029616325 scopus 로고
    • Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    • O'Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S: Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516-520, 1995.
    • (1995) Can J Surg , vol.38 , pp. 516-520
    • O'Brien, P.J.1    Meek, R.N.2    Blachut, P.A.3    Broekhuyse, H.M.4    Sabharwal, S.5
  • 43
    • 0003179093 scopus 로고    scopus 로고
    • Fracture and dislocation compendium
    • Orthopaedic Trauma Association: Fracture and Dislocation Compendium. J Orthop Trauma 10 (Suppl 1):32-40, 1996.
    • (1996) J Orthop Trauma , vol.10 , Issue.1 SUPPL. , pp. 32-40
  • 44
    • 0030013059 scopus 로고    scopus 로고
    • Gamma versus DHS nailing for extracapsular femoral fractures. Meta-analysis of ten randomised trials
    • Parker MJ, Pryor GA: Gamma versus DHS nailing for extracapsular femoral fractures. Meta-analysis of ten randomised trials. Int Orthop 20:163-168, 1996.
    • (1996) Int Orthop , vol.20 , pp. 163-168
    • Parker, M.J.1    Pryor, G.A.2
  • 45
    • 0023278988 scopus 로고
    • The effects of medullary reaming on the torsional strength of the femur
    • Pratt DJ, Papagiannopoulos G, Rees PH, Quinnell R: The effects of medullary reaming on the torsional strength of the femur. Injury 18:177-179, 1987.
    • (1987) Injury , vol.18 , pp. 177-179
    • Pratt, D.J.1    Papagiannopoulos, G.2    Rees, P.H.3    Quinnell, R.4
  • 46
    • 0001688654 scopus 로고
    • A self-adjusting nail-plate for fractures about the hip joint
    • Pugh WL: A self-adjusting nail-plate for fractures about the hip joint. J Bone Joint Surg 37A: 1085-1093, 1955.
    • (1955) J Bone Joint Surg , vol.37 A , pp. 1085-1093
    • Pugh, W.L.1
  • 47
    • 0027170493 scopus 로고
    • A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
    • Radford PJ, Needoff M, Webb JK: A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Joint Surg 758:789-793, 1993.
    • (1993) J Bone Joint Surg , vol.758 , pp. 789-793
    • Radford, P.J.1    Needoff, M.2    Webb, J.K.3
  • 48
    • 0032059046 scopus 로고    scopus 로고
    • Intramedullary fixation of high subtrochanteric femoral fractures: A study comparing two implant designs, the Gamma nail and the intramedullary hip screw
    • Rantanen J, Aro HT: Intramedullary fixation of high subtrochanteric femoral fractures: A study comparing two implant designs, the Gamma nail and the intramedullary hip screw. J Orthop Trauma 12:249-252, 1998.
    • (1998) J Orthop Trauma , vol.12 , pp. 249-252
    • Rantanen, J.1    Aro, H.T.2
  • 49
    • 0020623773 scopus 로고
    • Treatment of unstable intertrochanteric fractures with anatomic reduction and compression hip screw fixation
    • Rao JP, Banzon MT, Weiss AB, Rayhack J: Treatment of unstable intertrochanteric fractures with anatomic reduction and compression hip screw fixation. Clin Orthop 175:65-71, 1983.
    • (1983) Clin Orthop , vol.175 , pp. 65-71
    • Rao, J.P.1    Banzon, M.T.2    Weiss, A.B.3    Rayhack, J.4
  • 51
    • 0006586439 scopus 로고
    • Intertrochanteric hip fracture fixation-Gamma versus dynamic hip screw. A randomized prospective study
    • Sabharwal S, O'Brien PJ, Meek RN, Blachut PA, Broekhuyse HM: Intertrochanteric hip fracture fixation-Gamma versus dynamic hip screw. A randomized prospective study. J Bone Joint Surg 74B(Suppl III):281-288, 1992.
    • (1992) J Bone Joint Surg , vol.74 B , Issue.3 SUPPL. , pp. 281-288
    • Sabharwal, S.1    O'Brien, P.J.2    Meek, R.N.3    Blachut, P.A.4    Broekhuyse, H.M.5
  • 52
    • 0027398137 scopus 로고
    • Internal fixation of proximal femur fractures: A biomechanical comparison of the Gamma locking nail and the Omega compression hip screw
    • Shaw JA, Wilson S: Internal fixation of proximal femur fractures: A biomechanical comparison of the Gamma Locking Nail and the Omega Compression Hip Screw. Orthop Rev 22:61-68, 1993.
    • (1993) Orthop Rev , vol.22 , pp. 61-68
    • Shaw, J.A.1    Wilson, S.2
  • 53
    • 0024328634 scopus 로고
    • Sliding hip screws: Modes of failure
    • Simpson AH, Varty K, Dodd CA: Sliding hip screws: Modes of failure. Injury 20:227-231, 1989.
    • (1989) Injury , vol.20 , pp. 227-231
    • Simpson, A.H.1    Varty, K.2    Dodd, C.A.3
  • 54
    • 0026841255 scopus 로고
    • The Gamma nail, sliding-compression plate. A comparison between the long-term results obtained in two similar series
    • Tigani D, Laus M, Bettelli G, Boriani S, Giunti A: The Gamma nail, sliding-compression plate. A comparison between the long-term results obtained in two similar series. Chir Organi Mov 77:151-158, 1992.
    • (1992) Chir Organi Mov , vol.77 , pp. 151-158
    • Tigani, D.1    Laus, M.2    Bettelli, G.3    Boriani, S.4    Giunti, A.5
  • 55
    • 0031969583 scopus 로고    scopus 로고
    • Use of the Gamma nail in the treatment of fractures of the proximal femur
    • Valverde JA, Alonso MG, Porro JG, et al: Use of the Gamma nail in the treatment of fractures of the proximal femur. Clin Orthop 350:56-61, 1998.
    • (1998) Clin Orthop , vol.350 , pp. 56-61
    • Valverde, J.A.1    Alonso, M.G.2    Porro, J.G.3
  • 56
    • 0026628222 scopus 로고
    • Complications associated with the use of the Gamma nail
    • Williams WW, Parker BC: Complications associated with the use of the Gamma nail. Injury 23:291-292, 1992.
    • (1992) Injury , vol.23 , pp. 291-292
    • Williams, W.W.1    Parker, B.C.2
  • 57
    • 0020076988 scopus 로고
    • Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation
    • Wolfgang GL, Bryant MH, O'Neill JP: Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop 163:148-158, 1982.
    • (1982) Clin Orthop , vol.163 , pp. 148-158
    • Wolfgang, G.L.1    Bryant, M.H.2    O'Neill, J.P.3
  • 58
  • 59
    • 0014129409 scopus 로고
    • A new fixation device for subtrochanteric fractures of the femur: A preliminary report
    • Zickel RE: A new fixation device for subtrochanteric fractures of the femur: A preliminary report. Clin Orthop 54:115-123, 1967.
    • (1967) Clin Orthop , vol.54 , pp. 115-123
    • Zickel, R.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.