메뉴 건너뛰기




Volumn 21, Issue 2, 2000, Pages 221-227

Tracing air flow and diagnosing hypopnoeas in normal subjects

Author keywords

Air flow measurements; New method; Obstructive sleep apnoea syndrome; Polysomnography; Pressure measurements; Surgery

Indexed keywords

AIR; SLEEP RESEARCH; THERMISTORS;

EID: 0034120641     PISSN: 09673334     EISSN: None     Source Type: Journal    
DOI: 10.1088/0967-3334/21/2/302     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 0034049985 scopus 로고    scopus 로고
    • Advantages of measuring airflow in the pharynx with internal thermistors
    • at press
    • Akre H and Skatvedt O 2000 Advantages of measuring airflow in the pharynx with internal thermistors Eur. Arch. Otorhinolaryngol. at press
    • (2000) Eur. Arch. Otorhinolaryngol.
    • Akre, H.1    Skatvedt, O.2
  • 2
    • 0030898184 scopus 로고    scopus 로고
    • Comparison of direct and indirect measurements of respiratory airflow: Implications for hypopneas
    • Berg S, Haight J S, Yap V, Hoffstein V and Cole P 1997 Comparison of direct and indirect measurements of respiratory airflow: implications for hypopneas Sleep 20 60-4
    • (1997) Sleep , vol.20 , pp. 60-64
    • Berg, S.1    Haight, J.S.2    Yap, V.3    Hoffstein, V.4    Cole, P.5
  • 3
    • 0029004713 scopus 로고
    • Continuous intrathoracic pressure monitoring with a new esophageal microchip catheter in sleep-related upper airway obstructions
    • Berg S, Hybbinette J C, Gislason T and Hawke M 1995 Continuous intrathoracic pressure monitoring with a new esophageal microchip catheter in sleep-related upper airway obstructions J. Otolaryngol. 24 160-4
    • (1995) J. Otolaryngol. , vol.24 , pp. 160-164
    • Berg, S.1    Hybbinette, J.C.2    Gislason, T.3    Hawke, M.4
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J M and Altman D G 1986 Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0021715051 scopus 로고
    • Measurement error in visually scored electrophysiological data: Respiration during sleep
    • Bliwise D, Bliwise N G, Kraemer H C and Dement W 1994 Measurement error in visually scored electrophysiological data: respiration during sleep J. Neurosci. Methods 12 49-56
    • (1994) J. Neurosci. Methods , vol.12 , pp. 49-56
    • Bliwise, D.1    Bliwise, N.G.2    Kraemer, H.C.3    Dement, W.4
  • 11
    • 0030924534 scopus 로고    scopus 로고
    • Practice parameters for the indications for polysomnography and related procedures
    • Polysomnography Task Force, American Sleep Disorders Association Standards of Practice Committee 1997 Practice parameters for the indications for polysomnography and related procedures Sleep 20 406-22
    • (1997) Sleep , vol.20 , pp. 406-422
  • 12
    • 0029843725 scopus 로고    scopus 로고
    • Nocturnal polysomnography with and without continuous pharyngeal and esophageal pressure measurements
    • Skatvedt O, Akre H and Godtlibsen O B 1996 Nocturnal polysomnography with and without continuous pharyngeal and esophageal pressure measurements Sleep 19 485-90
    • (1996) Sleep , vol.19 , pp. 485-490
    • Skatvedt, O.1    Akre, H.2    Godtlibsen, O.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.