-
1
-
-
0014755950
-
Ultrasonics and selected physical properties of bone
-
Abendschein W., Hyatt G.W. Ultrasonics and selected physical properties of bone. Clin Orthop. 69:1970;294-301.
-
(1970)
Clin Orthop
, vol.69
, pp. 294-301
-
-
Abendschein, W.1
Hyatt, G.W.2
-
2
-
-
0023522205
-
Elastic properties of cancellous bone: Measurement by an ultrasonic technique
-
Ashman R.B., Corin J.D., Turner C.H. Elastic properties of cancellous bone Measurement by an ultrasonic technique . J Biomech. 20:1987;979-986.
-
(1987)
J Biomech
, vol.20
, pp. 979-986
-
-
Ashman, R.B.1
Corin, J.D.2
Turner, C.H.3
-
3
-
-
0021213283
-
A continuous wave technique for the measurement of the elastic properties of cortical bone
-
Ashman R.B., Cowin S.C., van Buskirk W.C., Rice J.C. A continuous wave technique for the measurement of the elastic properties of cortical bone. J Biomech. 17:1984;349-361.
-
(1984)
J Biomech
, vol.17
, pp. 349-361
-
-
Ashman, R.B.1
Cowin, S.C.2
Van Buskirk, W.C.3
Rice, J.C.4
-
4
-
-
0023887316
-
Elastic modulus of trabecular bone material
-
Ashman R.B., Rho J.Y. Elastic modulus of trabecular bone material. J Biomech. 21:1988;177-181.
-
(1988)
J Biomech
, vol.21
, pp. 177-181
-
-
Ashman, R.B.1
Rho, J.Y.2
-
5
-
-
0023687444
-
Ultrasound attenuation of the os calcis in women with osteoporosis and hip fractures
-
Baran D.T., Kelly A.M., Karellas A., Gionet M., Price M., Leahy D., Steuterman S., McSherry B., Roche J. Ultrasound attenuation of the os calcis in women with osteoporosis and hip fractures. Calcif Tissue Int. 43:1988;138-142.
-
(1988)
Calcif Tissue Int
, vol.43
, pp. 138-142
-
-
Baran, D.T.1
Kelly, A.M.2
Karellas, A.3
Gionet, M.4
Price, M.5
Leahy, D.6
Steuterman, S.7
McSherry, B.8
Roche, J.9
-
6
-
-
0030934837
-
Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women. A prospective study
-
Bauer D.C., Gluer C.C., Cauley J.A., Vogt T.M., Ensrud K.E., Genant H.K., Black D.M. Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women. A prospective study. Arch Int Med. 157:1997;629-634.
-
(1997)
Arch Int Med
, vol.157
, pp. 629-634
-
-
Bauer, D.C.1
Gluer, C.C.2
Cauley, J.A.3
Vogt, T.M.4
Ensrud, K.E.5
Genant, H.K.6
Black, D.M.7
-
7
-
-
0020004785
-
Ultrasonic analysis of the Young's modulus of cortical bone
-
Bonfield W., Tully A.E. Ultrasonic analysis of the Young's modulus of cortical bone. J Biomed Eng. 4:1982;23-27.
-
(1982)
J Biomed Eng
, vol.4
, pp. 23-27
-
-
Bonfield, W.1
Tully, A.E.2
-
8
-
-
0029005626
-
Bone loss after tibial fracture: Evaluated by dual-energy x-ray absorptiometry
-
Eyres K.S., Kanis J.A. Bone loss after tibial fracture Evaluated by dual-energy x-ray absorptiometry . J Bone Jt Surg. 77-B:1995;473-478.
-
(1995)
J Bone Jt Surg
, vol.77
, pp. 473-478
-
-
Eyres, K.S.1
Kanis, J.A.2
-
9
-
-
0028886520
-
Quantitative ultrasound of the tibia: A novel approach for assessment of bone status
-
Foldes A.J., Rimon A., Keinan D.D., Popovtzer M.M. Quantitative ultrasound of the tibia A novel approach for assessment of bone status . Bone. 17:1995;363-367.
-
(1995)
Bone
, vol.17
, pp. 363-367
-
-
Foldes, A.J.1
Rimon, A.2
Keinan, D.D.3
Popovtzer, M.M.4
-
11
-
-
9344263428
-
Noninvasive assessment of bone mineral and structure: State of the art
-
Genant H.K., Engelke K., Fuerst T., Gluer C.C., Gramp S., Harris S.T., Jergas M., Lang T., Lu Y., Majumdar S., Mathur A., Takada M. Noninvasive assessment of bone mineral and structure State of the art . J Bone Miner Res. 11:1996;707-730.
-
(1996)
J Bone Miner Res
, vol.11
, pp. 707-730
-
-
Genant, H.K.1
Engelke, K.2
Fuerst, T.3
Gluer, C.C.4
Gramp, S.5
Harris, S.T.6
Jergas, M.7
Lang, T.8
Lu, Y.9
Majumdar, S.10
Mathur, A.11
Takada, M.12
-
12
-
-
0027204802
-
Broadband ultrasound attenuation signals depend on trabecular orientation: An in vitro study
-
Gluer C.C., Wu C.Y., Genant H.K. Broadband ultrasound attenuation signals depend on trabecular orientation An in vitro study . Osteopor Int. 3:1993;185-191.
-
(1993)
Osteopor Int
, vol.3
, pp. 185-191
-
-
Gluer, C.C.1
Wu, C.Y.2
Genant, H.K.3
-
13
-
-
0028358570
-
Three quantitative ultrasound parameters reflect bone structure
-
Gluer C.C., Wu C.Y., Jergas M., Goldstein S.A., Genant H.K. Three quantitative ultrasound parameters reflect bone structure. Calcif Tissue Int. 55:1994;46-52.
-
(1994)
Calcif Tissue Int
, vol.55
, pp. 46-52
-
-
Gluer, C.C.1
Wu, C.Y.2
Jergas, M.3
Goldstein, S.A.4
Genant, H.K.5
-
14
-
-
0029151174
-
Do ultrasound measurements on the os calcis reflect more the bone microarchitecture than the bone mass?: A two dimensional histomorphometric study
-
Hans D., Arlot M.E., Schott A.M., Roux J.P., Kotzki P.O., Meunier P.J. Do ultrasound measurements on the os calcis reflect more the bone microarchitecture than the bone mass? A two dimensional histomorphometric study . Bone. 16:1995;295-300.
-
(1995)
Bone
, vol.16
, pp. 295-300
-
-
Hans, D.1
Arlot, M.E.2
Schott, A.M.3
Roux, J.P.4
Kotzki, P.O.5
Meunier, P.J.6
-
15
-
-
0030858059
-
The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro
-
Hodgkinson R., Njeh C.F., Currey J.D., Langton C.M. The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro. Bone. 21:1997;183-190.
-
(1997)
Bone
, vol.21
, pp. 183-190
-
-
Hodgkinson, R.1
Njeh, C.F.2
Currey, J.D.3
Langton, C.M.4
-
16
-
-
0029029258
-
Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual x-ray absorptiometry
-
Jergas M., Breitenseher M., Gluer C.C., Yu W., Genant H.K. Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual x-ray absorptiometry. J Bone Miner Res. 10:1995;1101-1110.
-
(1995)
J Bone Miner Res
, vol.10
, pp. 1101-1110
-
-
Jergas, M.1
Breitenseher, M.2
Gluer, C.C.3
Yu, W.4
Genant, H.K.5
-
18
-
-
0027489310
-
Architecture in cortical bone and ultrasound transmission velocity
-
Kann P., Schulz U., Nink M., Pfutzner A., Schrezenmeir J., Beyer J. Architecture in cortical bone and ultrasound transmission velocity. Clin Rheumatol. 12:1993;364-367.
-
(1993)
Clin Rheumatol
, vol.12
, pp. 364-367
-
-
Kann, P.1
Schulz, U.2
Nink, M.3
Pfutzner, A.4
Schrezenmeir, J.5
Beyer, J.6
-
20
-
-
0030176206
-
Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation
-
Langton C.M., Njeh C.F., Hodgkinson R., Currey J.D. Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation. Bone. 18:1996;495-503.
-
(1996)
Bone
, vol.18
, pp. 495-503
-
-
Langton, C.M.1
Njeh, C.F.2
Hodgkinson, R.3
Currey, J.D.4
-
21
-
-
0030804819
-
Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
-
Lee S.C., Coan B.S., Bouxsein M.L. Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone. Bone. 21:1997;119-125.
-
(1997)
Bone
, vol.21
, pp. 119-125
-
-
Lee, S.C.1
Coan, B.S.2
Bouxsein, M.L.3
-
22
-
-
0031264061
-
Ultrasound of the tibia - precision error, left versus right sides and correlation with bone mineral density
-
Leong K.H. Ultrasound of the tibia - precision error, left versus right sides and correlation with bone mineral density. Ann Acad Med Singapore. 26:1997;747-749.
-
(1997)
Ann Acad Med Singapore
, vol.26
, pp. 747-749
-
-
Leong, K.H.1
-
23
-
-
0025095581
-
Broadband ultrasound attenuation in the os calcis: Relationship to bone mineral at other skeletal sites
-
McCloskey E.V., Murray S.A., Miller C., Charlesworth D., Tindale W., O'Doherty D.P. Broadband ultrasound attenuation in the os calcis Relationship to bone mineral at other skeletal sites . Clin Sci. 78:1990;227-233.
-
(1990)
Clin Sci
, vol.78
, pp. 227-233
-
-
McCloskey, E.V.1
Murray, S.A.2
Miller, C.3
Charlesworth, D.4
Tindale, W.5
O'Doherty, D.P.6
-
24
-
-
0017652530
-
Radiographical and pathological assessment of the activity of Paget's disease of bone
-
Milgram J.W. Radiographical and pathological assessment of the activity of Paget's disease of bone. Clin Orthop. 127:1977;43-54.
-
(1977)
Clin Orthop
, vol.127
, pp. 43-54
-
-
Milgram, J.W.1
-
25
-
-
0030060684
-
A precise method for the assessment of tibial ultrasound velocity
-
Orgee J.M., Foster H., McCloskey E.V., Khan S., Coombes G., Kanis J.A. A precise method for the assessment of tibial ultrasound velocity. Osteopor Int. 6:1996;1-7.
-
(1996)
Osteopor Int
, vol.6
, pp. 1-7
-
-
Orgee, J.M.1
Foster, H.2
McCloskey, E.V.3
Khan, S.4
Coombes, G.5
Kanis, J.A.6
-
28
-
-
0026076661
-
Ultrasonic velocity as a predictor of strength in bovine cancellous bone
-
Turner C.H., Eich M. Ultrasonic velocity as a predictor of strength in bovine cancellous bone. Calcif Tissue Int. 49:1991;116-119.
-
(1991)
Calcif Tissue Int
, vol.49
, pp. 116-119
-
-
Turner, C.H.1
Eich, M.2
|