메뉴 건너뛰기




Volumn 43, Issue 6, 2000, Pages 913-916

Multiple inversion recovery MR subtraction imaging of human ventilation from inhalation of room air and pure oxygen

Author keywords

Lung ventilation; MIR; MRI; Multiple inversion recovery; Oxygen ventilation imaging

Indexed keywords

BIOLOGICAL ORGANS; OXYGEN; RECOVERY;

EID: 0034114915     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/1522-2594(200006)43:6<913::AID-MRM21>3.0.CO;2-P     Document Type: Article
Times cited : (42)

References (20)
  • 1
    • 0019309608 scopus 로고
    • Lung imaging with radioaerosols for the assessment of airway disease
    • Hayes M, Taplin GV. Lung imaging with radioaerosols for the assessment of airway disease. Semin Nucl Med 1980;10:243-251.
    • (1980) Semin Nucl Med , vol.10 , pp. 243-251
    • Hayes, M.1    Taplin, G.V.2
  • 5
    • 0029907856 scopus 로고    scopus 로고
    • Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic; resonance imaging
    • Edelman KR, Hatahu H, Tadamura E, Li W, Prasad PV. Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic; resonance imaging. Nat Med 1996;2:1236-1239.
    • (1996) Nat Med , vol.2 , pp. 1236-1239
    • Edelman, K.R.1    Hatahu, H.2    Tadamura, E.3    Li, W.4    Prasad, P.V.5
  • 8
    • 0033029722 scopus 로고    scopus 로고
    • Oxygen-enhanced magnetic resonance ventilation imaging of the human lung at 0.2 T and 1.5 T
    • Stock KW, Chen Q, Morrin M, Hatabu H, Edelman RR. Oxygen-enhanced magnetic resonance ventilation imaging of the human lung at 0.2 T and 1.5 T. J Magn Reson Imaging 1999;9:838-841.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 838-841
    • Stock, K.W.1    Chen, Q.2    Morrin, M.3    Hatabu, H.4    Edelman, R.R.5
  • 10
    • 0001945010 scopus 로고    scopus 로고
    • Noninvasive ventilation-perfusion MR imaging using oxygen and FAIRER in humans and in a porcine model of airway obstruction
    • Philadelphia
    • Mai VM, Chen Q, Gladstone S, Li W, Hatabu H, Edelman RR. Noninvasive ventilation-perfusion MR imaging using oxygen and FAIRER in humans and in a porcine model of airway obstruction (abstr). In: Proceedings of the ISMRM, 7th Annual Meeting, Philadelphia, 1999. p 137.
    • (1999) Proceedings of the ISMRM, 7th Annual Meeting , pp. 137
    • Mai, V.M.1    Chen, Q.2    Gladstone, S.3    Li, W.4    Hatabu, H.5    Edelman, R.R.6
  • 11
    • 0025875173 scopus 로고
    • Multiple inversion recovery reduces static tissue signal in angiograms
    • Dixon WT, Sardashti M, Castillo M, Slump GP. Multiple inversion recovery reduces static tissue signal in angiograms. Magn Reson Med 1991;18:257-268.
    • (1991) Magn Reson Med , vol.18 , pp. 257-268
    • Dixon, W.T.1    Sardashti, M.2    Castillo, M.3    Slump, G.P.4
  • 12
    • 0032948001 scopus 로고    scopus 로고
    • 1H MRI using multiple inversion recovery to simultaneously suppress signal contributions from fat and muscle
    • 1H MRI using multiple inversion recovery to simultaneously suppress signal contributions from fat and muscle. Magn Reson Med 1999;41:866-870.
    • (1999) Magn Reson Med , vol.41 , pp. 866-870
    • Mai, V.M.1    Knight-Scott, J.2    Berr, S.S.3
  • 13
    • 0002926370 scopus 로고
    • A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurements
    • Case TA, Durney CH, Ailion DC, Cutillo AG, Morris AH. A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: calculations and measurements. J Magn Reson 1987;73:304-314.
    • (1987) J Magn Reson , vol.73 , pp. 304-314
    • Case, T.A.1    Durney, C.H.2    Ailion, D.C.3    Cutillo, A.G.4    Morris, A.H.5
  • 15
    • 0028910197 scopus 로고
    • Multislice, breath-hold imaging of the lung with submillisecond echo times
    • Alsop DC, Hatabu H, Bonnet M, Listerud J, Gefter W. Multislice, breath-hold imaging of the lung with submillisecond echo times. Magn Reson Med 1995;33:678-682.
    • (1995) Magn Reson Med , vol.33 , pp. 678-682
    • Alsop, D.C.1    Hatabu, H.2    Bonnet, M.3    Listerud, J.4    Gefter, W.5
  • 16
    • 0025876984 scopus 로고
    • Lung parenchyma: Projection reconstruction MR imaging
    • Bergin CJ, Pauly JM, Macovski A. Lung parenchyma: projection reconstruction MR imaging. Radiology 1991;179:777-781.
    • (1991) Radiology , vol.179 , pp. 777-781
    • Bergin, C.J.1    Pauly, J.M.2    Macovski, A.3
  • 17
    • 0028932274 scopus 로고
    • Quantitative mapping of ocular oxygenation using magnetic resonance imaging
    • Berkowitz BA, Wilson CA. Quantitative mapping of ocular oxygenation using magnetic resonance imaging. Magn Reson Med 1995;33:579-581.
    • (1995) Magn Reson Med , vol.33 , pp. 579-581
    • Berkowitz, B.A.1    Wilson, C.A.2
  • 18
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent of blood oxygenation
    • Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent of blood oxygenation. Proc Natl Acad Sci USA 1990;87:9868-9872.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 19
    • 0032945093 scopus 로고    scopus 로고
    • Noninvasive MR perfusion imaging of pulmonary parenchyma using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER)
    • Mai VM, Hagspiel KD, Christopher JM, et al. Noninvasive MR perfusion imaging of pulmonary parenchyma using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER). Magn Reson Imaging 1999;17:355-361.
    • (1999) Magn Reson Imaging , vol.17 , pp. 355-361
    • Mai, V.M.1    Hagspiel, K.D.2    Christopher, J.M.3
  • 20
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 1999;9:483-487.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.