메뉴 건너뛰기




Volumn 11, Issue 3, 2000, Pages 305-308

Inability of serial fibrin monomer measurements to predict or exclude deep venous thrombosis in asymptomatic patients undergoing total knee arthroplasty

Author keywords

Deep venous thrombosis; Fibrin degradation products; Fibrin monomer; Total knee arthroplasty

Indexed keywords

FIBRIN MONOMER;

EID: 0034113923     PISSN: 09575235     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0032940394 scopus 로고    scopus 로고
    • Performance of a new fibrin monomer assay to exclude deep vein thrombosis in symptomatic outpatients
    • 1. Caliezi C, Fünfsinn N, Mauron T, Sulzer I, Ulrich M, Cottier C, et al. Performance of a new fibrin monomer assay to exclude deep vein thrombosis in symptomatic outpatients. Thromb Haemost 1999; 81: 50-53.
    • (1999) Thromb Haemost , vol.81 , pp. 50-53
    • Caliezi, C.1    Fünfsinn, N.2    Mauron, T.3    Sulzer, I.4    Ulrich, M.5    Cottier, C.6
  • 2
    • 0033065035 scopus 로고    scopus 로고
    • Performances of the fibrin monomer tests for the exclusion of pulmonary embolism in symptomatic outpatients
    • 2. Reber G, Bounameaux H, Perrier A, de Moerloose P. Performances of the fibrin monomer tests for the exclusion of pulmonary embolism in symptomatic outpatients. Thromb Haemost 1999; 81: 221-223.
    • (1999) Thromb Haemost , vol.81 , pp. 221-223
    • Reber, G.1    Bounameaux, H.2    Perrier, A.3    De Moerloose, P.4
  • 3
    • 0027472265 scopus 로고
    • Binding of a new monoclonal antibody against N-terminal heptapeptide of fibrin alpha-chain to fibrin polymerization site 'A': Effects of fibrinogen and fibrinogen derivatives, and pretreatment of samples with NaSCN
    • 3. Dempfle CE, Dollman M, Lill H, Puzzovio D, Dessauer A, Heene DL. Binding of a new monoclonal antibody against N-terminal heptapeptide of fibrin alpha-chain to fibrin polymerization site 'A': effects of fibrinogen and fibrinogen derivatives, and pretreatment of samples with NaSCN. Blood Coag Fibrinol 1993; 4: 79-86.
    • (1993) Blood Coag Fibrinol , vol.4 , pp. 79-86
    • Dempfle, C.E.1    Dollman, M.2    Lill, H.3    Puzzovio, D.4    Dessauer, A.5    Heene, D.L.6
  • 4
    • 0030000404 scopus 로고    scopus 로고
    • The value of quantitative fibrin monomer determination in the early diagnosis of postoperative deep vein thrombosis
    • 4. Vogel G, Demplfle CE, Spannagl M, Leskopf W. The value of quantitative fibrin monomer determination in the early diagnosis of postoperative deep vein thrombosis. Thromb Res 1996; 81: 241-251.
    • (1996) Thromb Res , vol.81 , pp. 241-251
    • Vogel, G.1    Demplfle, C.E.2    Spannagl, M.3    Leskopf, W.4
  • 6
    • 0027475513 scopus 로고
    • A new immunoassay for soluble fibrin enables a more sensitive detection of the activation state of blood coagulation in vivo
    • 6. Lill H, Spannagl M, Trauner A, Schramm W, Schuller D, Ofenloch-Haehnle B, et al. A new immunoassay for soluble fibrin enables a more sensitive detection of the activation state of blood coagulation in vivo. Blood Coag Fibrinol 1993; 4: 97-102.
    • (1993) Blood Coag Fibrinol , vol.4 , pp. 97-102
    • Lill, H.1    Spannagl, M.2    Trauner, A.3    Schramm, W.4    Schuller, D.5    Ofenloch-Haehnle, B.6
  • 7
    • 0020083498 scopus 로고
    • The meaning and use of the area under the receiver operator characteristic (ROC) curve
    • 7. Hanley JA, McNeil BJ. The meaning and use of the area under the receiver operator characteristic (ROC) curve. Radiology 1982; 143: 29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 9
    • 0029870420 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism by a decision analysis-based strategy including clinical probability, D-dimer levels, and ultrasonography: A management study
    • 9. Perrier A, Bounameaux H, Morabia A, Slosman D, Didier D, Unger PF, et al. Diagnosis of pulmonary embolism by a decision analysis-based strategy including clinical probability, D-dimer levels, and ultrasonography: a management study. Arch Intern Med 1996; 156: 531-536.
    • (1996) Arch Intern Med , vol.156 , pp. 531-536
    • Perrier, A.1    Bounameaux, H.2    Morabia, A.3    Slosman, D.4    Didier, D.5    Unger, P.F.6
  • 11
    • 0027477997 scopus 로고
    • D-Dimer plasma concentration in various clinical conditions: Implication for the use of this test in the diagnostic approach of venous thromboembolism
    • 11. Raimondi P, Bongard O, de Moerloose P, Reber G, Waldvogel F, Bounameaux H. D-Dimer plasma concentration in various clinical conditions: implication for the use of this test in the diagnostic approach of venous thromboembolism. Thromb Res 1993; 69: 125-130.
    • (1993) Thromb Res , vol.69 , pp. 125-130
    • Raimondi, P.1    Bongard, O.2    De Moerloose, P.3    Reber, G.4    Waldvogel, F.5    Bounameaux, H.6
  • 12
    • 0028357478 scopus 로고
    • D-Dimer plasma measurement in patients undergoing major hip surgery: Use in prediction and diagnosis of postoperative proximal vein thrombosis
    • 12. Bongard O, Wicky J, Peter R, Simonowska S, Vogel JJ, de Moerloose P, et al. D-Dimer plasma measurement in patients undergoing major hip surgery: use in prediction and diagnosis of postoperative proximal vein thrombosis. Thromb Res 1994; 74: 487-493.
    • (1994) Thromb Res , vol.74 , pp. 487-493
    • Bongard, O.1    Wicky, J.2    Peter, R.3    Simonowska, S.4    Vogel, J.J.5    De Moerloose, P.6
  • 13
    • 0031050358 scopus 로고    scopus 로고
    • Coagulation markers in the prediction of venous thrombosis after elective hip surgery
    • 13. Cofrancesco E, Cortallero M, Corradi A, Ravasi F, Bertocchi F. Coagulation markers in the prediction of venous thrombosis after elective hip surgery. Thromb Haemost 1997; 77: 267-269.
    • (1997) Thromb Haemost , vol.77 , pp. 267-269
    • Cofrancesco, E.1    Cortallero, M.2    Corradi, A.3    Ravasi, F.4    Bertocchi, F.5
  • 14
    • 0025042195 scopus 로고
    • Thrombin-antithrombin III complex and fibrin degradation products in plasma: Surgery and postoperative deep vein thrombosis
    • 14. Jorgensen LN, Lind B, Hauch O, Leffers A, Albrecht-Beste E, Konradsen LA. Thrombin-antithrombin III complex and fibrin degradation products in plasma: surgery and postoperative deep vein thrombosis. Thromb Res 1990; 59: 69-76.
    • (1990) Thromb Res , vol.59 , pp. 69-76
    • Jorgensen, L.N.1    Lind, B.2    Hauch, O.3    Leffers, A.4    Albrecht-Beste, E.5    Konradsen, L.A.6
  • 15
    • 0027946902 scopus 로고
    • Plasma d-dimer as a marker for postoperative deep venous thrombosis. A study after total hip or knee replacement
    • 15. Dunn ID, Hui AC, Triffit PD, Crozier AE, Gregg PJ, Sinclair ME, et al. Plasma D-dimer as a marker for postoperative deep venous thrombosis. A study after total hip or knee replacement. Thromb Haemost 1994; 72: 663-665.
    • (1994) Thromb Haemost , vol.72 , pp. 663-665
    • Dunn, I.D.1    Hui, A.C.2    Triffit, P.D.3    Crozier, A.E.4    Gregg, P.J.5    Sinclair, M.E.6
  • 16
    • 0032957278 scopus 로고    scopus 로고
    • Occurrence of thrombosis and haemorrhage, relationship with anti-Xa, anti-IIa activities, and D-dimer plasma levels in patients receiving a low molecular weight heparin, enoxaparin or tinzaparine, to prevent deep vein thrombosis after hip surgery
    • 16. Bara L, Planes A, Samama M-M. Occurrence of thrombosis and haemorrhage, relationship with anti-Xa, anti-IIa activities, and D-dimer plasma levels in patients receiving a low molecular weight heparin, enoxaparin or tinzaparine, to prevent deep vein thrombosis after hip surgery. Br J Haematol 1999; 104: 230-240.
    • (1999) Br J Haematol , vol.104 , pp. 230-240
    • Bara, L.1    Planes, A.2    Samama, M.-M.3
  • 17
    • 0032465251 scopus 로고    scopus 로고
    • Measurement of plasma D-dimer is not useful in the prediction or diagnosis of postoperative deep vein thrombosis in patients undergoing total knee arthroplasty
    • 17. Bounameaux H, Miron M-J, Blanchard J, de Moerloose P, Leyvraz P-F. Measurement of plasma D-dimer is not useful in the prediction or diagnosis of postoperative deep vein thrombosis in patients undergoing total knee arthroplasty. Blood Coag Fibrinol 1998; 9: 749-752.
    • (1998) Blood Coag Fibrinol , vol.9 , pp. 749-752
    • Bounameaux, H.1    Miron, M.-J.2    Blanchard, J.3    De Moerloose, P.4    Leyvraz, P.-F.5
  • 18
    • 0030870378 scopus 로고    scopus 로고
    • Fibrin in plasma of patients with intravascular coagulation by fibrin-specific antibodies consists primarily of high molecular weight Factor XIIIa-crosslinked and plasmin-modified complexes partially containing fibrinopeptide A
    • 18. Pfitzner SA, Demplfle CE, Matsuda M, Heene DL. Fibrin in plasma of patients with intravascular coagulation by fibrin-specific antibodies consists primarily of high molecular weight Factor XIIIa-crosslinked and plasmin-modified complexes partially containing fibrinopeptide A. Thromb Haemost 1997; 78: 1069-1078.
    • (1997) Thromb Haemost , vol.78 , pp. 1069-1078
    • Pfitzner, S.A.1    Demplfle, C.E.2    Matsuda, M.3    Heene, D.L.4
  • 19
    • 0031395437 scopus 로고    scopus 로고
    • Postoperative activation of the haemostatic system. Influence of prolonged thromboprophylaxis in patients undergoing total hip arthroplasty
    • 19. Andersen BS. Postoperative activation of the haemostatic system. Influence of prolonged thromboprophylaxis in patients undergoing total hip arthroplasty. Haemostasis 1997; 27: 219-227.
    • (1997) Haemostasis , vol.27 , pp. 219-227
    • Andersen, B.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.