메뉴 건너뛰기




Volumn 10, Issue 2, 2000, Pages 91-95

On the use of partial AUC as an early exposure metric

Author keywords

Bioequivalence; Exposure; Metric; Partial AUC

Indexed keywords

AREA UNDER THE CURVE; BIOEQUIVALENCE; DRUG ABSORPTION; EXPOSURE; NOTE; PRIORITY JOURNAL;

EID: 0034112938     PISSN: 09280987     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0928-0987(99)00095-0     Document Type: Note
Times cited : (7)

References (14)
  • 2
    • 0026488257 scopus 로고
    • An alternative approach for assessment of rate of absorption in bioequivalence studies
    • Chen M.L. An alternative approach for assessment of rate of absorption in bioequivalence studies. Pharm. Res. 9:1992;1380-1385.
    • (1992) Pharm. Res. , vol.9 , pp. 1380-1385
    • Chen, M.L.1
  • 3
    • 0344019460 scopus 로고    scopus 로고
    • Dissolution specifications based on release rates
    • Elkoshi Z. Dissolution specifications based on release rates. J. Pharm. Sci. 88:1999;434-444.
    • (1999) J. Pharm. Sci. , vol.88 , pp. 434-444
    • Elkoshi, Z.1
  • 4
    • 0029611221 scopus 로고
    • Sensitive and specific determination of the equivalence of absorption rates
    • Endrenyi L., Al-Skaikh P. Sensitive and specific determination of the equivalence of absorption rates. Pharm. Res. 12:1995;1856-1864.
    • (1995) Pharm. Res. , vol.12 , pp. 1856-1864
    • Endrenyi, L.1    Al-Skaikh, P.2
  • 5
    • 0031944438 scopus 로고    scopus 로고
    • The duration of measuring partial AUCs for the assessment of bioequivalence
    • Endrenyi L., Csizmadia F., Tothfalusi L., Balch A.H., Chen M.L. The duration of measuring partial AUCs for the assessment of bioequivalence. Pharm. Res. 15:1998;399-404.
    • (1998) Pharm. Res. , vol.15 , pp. 399-404
    • Endrenyi, L.1    Csizmadia, F.2    Tothfalusi, L.3    Balch, A.H.4    Chen, M.L.5
  • 6
    • 0031689198 scopus 로고    scopus 로고
    • Metrics comparing simulated early concentration profiles for the determination of bioequivalence
    • Endrenyi L., Csizmadia F., Tothfalusi L., Chen M.L. Metrics comparing simulated early concentration profiles for the determination of bioequivalence. Pharm. Res. 15:1998;1292-1299.
    • (1998) Pharm. Res. , vol.15 , pp. 1292-1299
    • Endrenyi, L.1    Csizmadia, F.2    Tothfalusi, L.3    Chen, M.L.4
  • 7
    • 0028343433 scopus 로고
    • The cutoff time point of the partial area method for assessment of rate of absorption in bioequivalence studies
    • Macheras P., Symillides M., Reppas C. The cutoff time point of the partial area method for assessment of rate of absorption in bioequivalence studies. Pharm. Res. 11:1994;831-834.
    • (1994) Pharm. Res. , vol.11 , pp. 831-834
    • Macheras, P.1    Symillides, M.2    Reppas, C.3
  • 8
    • 0030455294 scopus 로고    scopus 로고
    • An improved intercept method for the assessment of rate in bioequivalence studies
    • Macheras P., Symillides M., Reppas C. An improved intercept method for the assessment of rate in bioequivalence studies. Pharm. Res. 13:1996;1755-1758.
    • (1996) Pharm. Res. , vol.13 , pp. 1755-1758
    • Macheras, P.1    Symillides, M.2    Reppas, C.3
  • 9
    • 0027987256 scopus 로고
    • Sensitivity of indirect metrics for assessing "rate" in bioequivalence studies - Moving the "goalposts" or changing the "game"
    • Rostami-Hodjegan A., Jackson P.R., Tucker G.T. Sensitivity of indirect metrics for assessing "rate" in bioequivalence studies - Moving the "goalposts" or changing the "game" J. Pharm. Sci. 83:1994;1554-1557.
    • (1994) J. Pharm. Sci. , vol.83 , pp. 1554-1557
    • Rostami-Hodjegan, A.1    Jackson, P.R.2    Tucker, G.T.3
  • 10
    • 0018394195 scopus 로고
    • Simultaneous modeling of pharmacokinetics and pharmacodynamics: Application to D-tubocurarine
    • Sheiner L.B., Stanski D.R., Vozeh S., Miller R.D., Ham J. Simultaneous modeling of pharmacokinetics and pharmacodynamics: application to D-tubocurarine. Clin. Pharmacol. Ther. 25:1979;358-371.
    • (1979) Clin. Pharmacol. Ther. , vol.25 , pp. 358-371
    • Sheiner, L.B.1    Stanski, D.R.2    Vozeh, S.3    Miller, R.D.4    Ham, J.5
  • 11
    • 0028989927 scopus 로고
    • max/AUC is an effective metric in investigations of bioequivalence
    • max/AUC is an effective metric in investigations of bioequivalence. Pharm. Res. 12:1995;937-942.
    • (1995) Pharm. Res. , vol.12 , pp. 937-942
    • Tothfalusi, L.1    Endrenyi, L.2
  • 12
    • 0029940802 scopus 로고    scopus 로고
    • Absorption rate vs. exposure: Which is more useful for bioequivalence testing?
    • Tozer T.N., Bois F.Y., Hauck W.W., Chen M., Williams R. Absorption rate vs. exposure: which is more useful for bioequivalence testing? Pharm. Res. 13:1996;453-456.
    • (1996) Pharm. Res. , vol.13 , pp. 453-456
    • Tozer, T.N.1    Bois, F.Y.2    Hauck, W.W.3    Chen, M.4    Williams, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.