메뉴 건너뛰기




Volumn 11, Issue 4, 2000, Pages 394-400

A comparison between segmented k-space FLASH and interleaved spiral MR coronary angiography sequences

Author keywords

Coronary arteries; MR imaging; Respiratory motion suppression; Spiral imaging

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; BREATHING; CLINICAL ARTICLE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; CORONARY ARTERY DISEASE; FEMALE; HUMAN; IMAGE QUALITY; MALE; PRIORITY JOURNAL; SIGNAL NOISE RATIO;

EID: 0034111170     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(200004)11:4<394::AID-JMRI7>3.0.CO;2-S     Document Type: Article
Times cited : (20)

References (29)
  • 1
    • 0027403101 scopus 로고
    • A preliminary report comparing magnetic resonance coronary angiography with conventional angiography
    • Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 1993;328:828-382.
    • (1993) N Engl J Med , vol.328 , pp. 828-382
    • Manning, W.J.1    Li, W.2    Edelman, R.R.3
  • 3
    • 0028036749 scopus 로고
    • Two-dimensional coronary MR angiography: Analysis of initial clinical results
    • Duerinckx A, Urman M. Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 1994;193:731-738.
    • (1994) Radiology , vol.193 , pp. 731-738
    • Duerinckx, A.1    Urman, M.2
  • 4
    • 0028866518 scopus 로고
    • Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course?
    • Post JC, van Rossum AC, Bronzwaer JG, et al. Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course? Circulation 1995;92:3163-3171.
    • (1995) Circulation , vol.92 , pp. 3163-3171
    • Post, J.C.1    Van Rossum, A.C.2    Bronzwaer, J.G.3
  • 6
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 1996;198:55-60.
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 9
    • 0031412991 scopus 로고    scopus 로고
    • Magnetic resonance navigator-echo monitoring of temporal changes in diaphragm position: Implications for magnetic resonance coronary angiography
    • Taylor AM, Jhooti P, Wiesmann F, Keegan J, Firmin DN, Pennell DJ. Magnetic resonance navigator-echo monitoring of temporal changes in diaphragm position: implications for magnetic resonance coronary angiography. J Magn Reson Imaging 1997;7:629-636.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 629-636
    • Taylor, A.M.1    Jhooti, P.2    Wiesmann, F.3    Keegan, J.4    Firmin, D.N.5    Pennell, D.J.6
  • 10
    • 0028826401 scopus 로고
    • Coronary artery imaging at 0.5 T using segmented 3D echo planar imaging
    • Börnert P, Jensen D. Coronary artery imaging at 0.5 T using segmented 3D echo planar imaging. Magn Reson Med 1995;34:779-785.
    • (1995) Magn Reson Med , vol.34 , pp. 779-785
    • Börnert, P.1    Jensen, D.2
  • 12
    • 0031724906 scopus 로고    scopus 로고
    • Two-dimensional multishot echo-planar coronary angiography
    • Slavin GS, Riderer SJ, Ehman RL. Two-dimensional multishot echo-planar coronary angiography. Magn Reson Med 1998;40:883-889.
    • (1998) Magn Reson Med , vol.40 , pp. 883-889
    • Slavin, G.S.1    Riderer, S.J.2    Ehman, R.L.3
  • 13
    • 0343822268 scopus 로고
    • Analysis of flow effects in echo-planar imaging
    • Butts K, Riederer SJ. Analysis of flow effects in echo-planar imaging. J Magn Reson Imaging 1992;1:643-650.
    • (1992) J Magn Reson Imaging , vol.1 , pp. 643-650
    • Butts, K.1    Riederer, S.J.2
  • 17
    • 0000122181 scopus 로고    scopus 로고
    • Spiral echo-planar imaging
    • Schmitt F, Stehling MK, Turner R, editors. New York: Springer-Verlag
    • Meyer CH. Spiral echo-planar imaging. In: Schmitt F, Stehling MK, Turner R, editors. Echo-planar imaging. Theory, technique and application. New York: Springer-Verlag, 1998. p 633-658.
    • (1998) Theory, Technique and Application , pp. 633-658
    • Meyer, C.H.1
  • 18
    • 0032965411 scopus 로고    scopus 로고
    • Coronary artery imaging in a 0.5 Tesla scanner: Implementation of real-time navigator echo controlled segmented k-space FLASH and interleaved spiral sequences
    • Keegan J, Gatehouse PD, Taylor AM, Yang GZ, Jhooti P, Firmin DN. Coronary artery imaging in a 0.5 Tesla scanner: implementation of real-time navigator echo controlled segmented k-space FLASH and interleaved spiral sequences. Magn Reson Med 1999;41:392-399.
    • (1999) Magn Reson Med , vol.41 , pp. 392-399
    • Keegan, J.1    Gatehouse, P.D.2    Taylor, A.M.3    Yang, G.Z.4    Jhooti, P.5    Firmin, D.N.6
  • 19
    • 0031030144 scopus 로고    scopus 로고
    • Assessing contrast on MR images
    • Wolfe SD, Balaban RS. Assessing contrast on MR images. Radiology 1996;202:25-29.
    • (1996) Radiology , vol.202 , pp. 25-29
    • Wolfe, S.D.1    Balaban, R.S.2
  • 22
    • 0033301611 scopus 로고    scopus 로고
    • Calculation of a subject specific adaptive motion correction factor for improved real-time navigator echo gated MR coronary angiography
    • Taylor AM, Keegan J, Jhooti P, Firmin DN, Pennell DJ. Calculation of a subject specific adaptive motion correction factor for improved real-time navigator echo gated MR coronary angiography. J Cardiovasc Magnc Reson 1999;1:131-138.
    • (1999) J Cardiovasc Magnc Reson , vol.1 , pp. 131-138
    • Taylor, A.M.1    Keegan, J.2    Jhooti, P.3    Firmin, D.N.4    Pennell, D.J.5
  • 24
    • 0033066947 scopus 로고    scopus 로고
    • 3D coronary imaging with phase reordering for improved scan efficiency
    • Jhooti P, Keegan J, Gatehouse PD, et al. 3D coronary imaging with phase reordering for improved scan efficiency. Magn Reson Med 1999;41:555-562.
    • (1999) Magn Reson Med , vol.41 , pp. 555-562
    • Jhooti, P.1    Keegan, J.2    Gatehouse, P.D.3
  • 25
    • 0032908729 scopus 로고    scopus 로고
    • Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography
    • Taylor AM, Jhooti P, Firmin DN, Pennell DJ. Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography. J Magn Reson Imaging 1999;9:395-401.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 395-401
    • Taylor, A.M.1    Jhooti, P.2    Firmin, D.N.3    Pennell, D.J.4
  • 26
    • 0029878647 scopus 로고    scopus 로고
    • Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: Effects of cardiac and respiratory motion
    • Hofman MBM, van Rossum AC, Sprenger M, Westerhof N. Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: effects of cardiac and respiratory motion. Magn Reson Med 1996;35:521-531.
    • (1996) Magn Reson Med , vol.35 , pp. 521-531
    • Hofman, M.B.M.1    Van Rossum, A.C.2    Sprenger, M.3    Westerhof, N.4
  • 27
  • 28
    • 0031809104 scopus 로고    scopus 로고
    • Three dimensional MRI of coronary arteries using an intravascular contrast agent
    • Li D, Dolan RP, Walovitch RC, Lauffer RB. Three dimensional MRI of coronary arteries using an intravascular contrast agent. Magn Reson Med 1998;39:1014-1018.
    • (1998) Magn Reson Med , vol.39 , pp. 1014-1018
    • Li, D.1    Dolan, R.P.2    Walovitch, R.C.3    Lauffer, R.B.4
  • 29
    • 0032968339 scopus 로고    scopus 로고
    • Safety and preliminary findings with the intravascular contrast agent, NC100150 injection, for MR coronary angiography
    • Taylor AM, Panting JR, Keegan J, et al. Safety and preliminary findings with the intravascular contrast agent, NC100150 Injection, for MR coronary angiography. J Magn Reson Imaging 1999; 9:220-227.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 220-227
    • Taylor, A.M.1    Panting, J.R.2    Keegan, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.