-
1
-
-
0028092055
-
Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
-
Hijazi ZM, Geggel RL (1994) Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am J Cardiol 74:925-929
-
(1994)
Am J Cardiol
, vol.74
, pp. 925-929
-
-
Hijazi, Z.M.1
Geggel, R.L.2
-
2
-
-
0030478046
-
Transcatheter closure of large patent ductus arteriosus ( > 4 mm) with multiple Gianturco coils: Immediate and mid-term results
-
Hijazi ZM, Geggel RL (1996) Transcatheter closure of large patent ductus arteriosus ( > 4 mm) with multiple Gianturco coils: immediate and mid-term results. Heart 76:536-540
-
(1996)
Heart
, vol.76
, pp. 536-540
-
-
Hijazi, Z.M.1
Geggel, R.L.2
-
3
-
-
0024558526
-
Angiographie classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion
-
Krichenko A, Benson LN, Burrows P, Moes CAP, McLaughlin P, Freedom RM (1989) Angiographie classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 63:877-880
-
(1989)
Am J Cardiol
, vol.63
, pp. 877-880
-
-
Krichenko, A.1
Benson, L.N.2
Burrows, P.3
Moes, C.A.P.4
McLaughlin, P.5
Freedom, R.M.6
-
4
-
-
0027379385
-
Transcatheter occlusion of patent ductus arteriosus with Gianturco coils
-
Lloyd TR, Fedderly R, Mendelsohn AM, Sandhu SK, Beekman RH (1993) Transcatheter occlusion of patent ductus arteriosus with Gianturco coils. Circulation 88:1412-1420
-
(1993)
Circulation
, vol.88
, pp. 1412-1420
-
-
Lloyd, T.R.1
Fedderly, R.2
Mendelsohn, A.M.3
Sandhu, S.K.4
Beekman, R.H.5
-
5
-
-
17444447441
-
Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results
-
Masura J, Walsh KP, Thanopoulous B, Chan C, Bass J, Goussous Y, Gavora P, Hijazi Z (1998) Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results. J Am Coll Cardiol 31:878-882
-
(1998)
J Am Coll Cardiol
, vol.31
, pp. 878-882
-
-
Masura, J.1
Walsh, K.P.2
Thanopoulous, B.3
Chan, C.4
Bass, J.5
Goussous, Y.6
Gavora, P.7
Hijazi, Z.8
-
6
-
-
0030836347
-
Percutaneous closure of patent ductus arteriosus using special screwing detachable coils
-
Podnar T, Masura J (1997) Percutaneous closure of patent ductus arteriosus using special screwing detachable coils. Cathet Cardiovasc Diagn 41:386-391
-
(1997)
Cathet Cardiovasc Diagn
, vol.41
, pp. 386-391
-
-
Podnar, T.1
Masura, J.2
-
7
-
-
0344820776
-
Transcatheter occlusion of residual patent ductus arteriosus after surgical ligation
-
Podnar T, Masura J (1999) Transcatheter occlusion of residual patent ductus arteriosus after surgical ligation. Pediatr Cardiol 20:126-130
-
(1999)
Pediatr Cardiol
, vol.20
, pp. 126-130
-
-
Podnar, T.1
Masura, J.2
-
8
-
-
0014079566
-
Der Verschluss des Ductus arteriosus persistens ohne Thorakotomie
-
Porstmann W, Wierny L, Warnke H (1967) Der Verschluss des Ductus arteriosus persistens ohne Thorakotomie. Thoraxchirurgie 15:199-203
-
(1967)
Thoraxchirurgie
, vol.15
, pp. 199-203
-
-
Porstmann, W.1
Wierny, L.2
Warnke, H.3
-
9
-
-
0031885582
-
Current therapy of the patent ductus arteriosus
-
Radtke WAK (1998) Current therapy of the patent ductus arteriosus. Curr Opin Cardiol 13:59-65
-
(1998)
Curr Opin Cardiol
, vol.13
, pp. 59-65
-
-
Radtke, W.A.K.1
-
10
-
-
0027301293
-
Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience
-
Rao PS, Sideris EB, Haddad J, Rey C, Hausdorf G, Wilson AD, Smith PA, Chopra PS (1993) Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience. Circulation 88:1119-1126
-
(1993)
Circulation
, vol.88
, pp. 1119-1126
-
-
Rao, P.S.1
Sideris, E.B.2
Haddad, J.3
Rey, C.4
Hausdorf, G.5
Wilson, A.D.6
Smith, P.A.7
Chopra, P.S.8
-
11
-
-
0023153198
-
Nonsurgical closure of patent ductus arteriosus: Clinical application of Rashkind PDA occluder system
-
Rashkind WJ, Mullins CE, Hellebrand WE, Tait MA (1987) Nonsurgical closure of patent ductus arteriosus: clinical application of Rashkind PDA occluder system. Circulation 75: 583-592
-
(1987)
Circulation
, vol.75
, pp. 583-592
-
-
Rashkind, W.J.1
Mullins, C.E.2
Hellebrand, W.E.3
Tait, M.A.4
-
12
-
-
0030332463
-
Closure of the arterial duct: Past, present, and future
-
Rigby ML (1996) Closure of the arterial duct: past, present, and future. (editorial). Heart 76:461-462
-
(1996)
Heart
, vol.76
, pp. 461-462
-
-
Rigby, M.L.1
-
13
-
-
0030473809
-
Evolving use of embolisation coils for occlusion of the arterial duct
-
Rosenthal E, Qureshi SA, Reidy J, Baker EJ, Tynan M (1996) Evolving use of embolisation coils for occlusion of the arterial duct. Heart 76:525-530
-
(1996)
Heart
, vol.76
, pp. 525-530
-
-
Rosenthal, E.1
Qureshi, S.A.2
Reidy, J.3
Baker, E.J.4
Tynan, M.5
-
14
-
-
0030812614
-
Percutaneous coil occlusion of patent ductus arteriosus
-
Rothman A, Lucas VW, Sklansky MS, Cocalis MW, Kashani IA (1997) Percutaneous coil occlusion of patent ductus arteriosus. J Pediatr 130:447-454
-
(1997)
J Pediatr
, vol.130
, pp. 447-454
-
-
Rothman, A.1
Lucas, V.W.2
Sklansky, M.S.3
Cocalis, M.W.4
Kashani, I.A.5
-
15
-
-
0030278794
-
Experimental evaluation of a new self-expanding patent ductus arteriosus occluder in a canine model
-
Sharafuddin MJA, Gu X, Titus JL, Sakinis AK, Pozza CH, Coleman CC, Cervera-Ceballos JJ, Aideyan OA, Amplatz K (1996) Experimental evaluation of a new self-expanding patent ductus arteriosus occluder in a canine model. J Vasc Interv Radiol 7:877-887
-
(1996)
J Vasc Interv Radiol
, vol.7
, pp. 877-887
-
-
Sharafuddin, M.J.A.1
Gu, X.2
Titus, J.L.3
Sakinis, A.K.4
Pozza, C.H.5
Coleman, C.C.6
Cervera-Ceballos, J.J.7
Aideyan, O.A.8
Amplatz, K.9
-
16
-
-
8044241592
-
Transcatheter occlussion of the patent ductus arteriosus with Cook detachable coils
-
Tometzki AJP, Arnold R, Peart I, Sreeram N, Abdulhamed JM, Godman MJ, Patel RG, Kitchiner DJ, Bu'Lock FA, Walsh KP (1996) Transcatheter occlussion of the patent ductus arteriosus with Cook detachable coils. Heart 76:531-535
-
(1996)
Heart
, vol.76
, pp. 531-535
-
-
Tometzki, A.J.P.1
Arnold, R.2
Peart, I.3
Sreeram, N.4
Abdulhamed, J.M.5
Godman, M.J.6
Patel, R.G.7
Kitchiner, D.J.8
Bu'Lock, F.A.9
Walsh, K.P.10
-
17
-
-
0029764568
-
Transcatheter occlusion of the arterial duct with Cook detachable coils: Early experience
-
Uzun O, Hancock S, Parsons JM, Dickinson DF, Gibbs JL (1996) Transcatheter occlusion of the arterial duct with Cook detachable coils: early experience. Heart 76:269-273
-
(1996)
Heart
, vol.76
, pp. 269-273
-
-
Uzun, O.1
Hancock, S.2
Parsons, J.M.3
Dickinson, D.F.4
Gibbs, J.L.5
-
18
-
-
0027423486
-
Results of transcatheter closure of patent ductus arteriosus with the Botalloccluder
-
Verin VE, Saveliev SV, Kolody SM, Prokubovski VI (1993) Results of transcatheter closure of patent ductus arteriosus with the Botalloccluder. J Am Coll Cardiol 22:1509-1514
-
(1993)
J Am Coll Cardiol
, vol.22
, pp. 1509-1514
-
-
Verin, V.E.1
Saveliev, S.V.2
Kolody, S.M.3
Prokubovski, V.I.4
|