메뉴 건너뛰기




Volumn 159, Issue 4, 2000, Pages 293-296

Percutaneous closure of patent ductus arteriosus: Complementary use of detachable Cook patent ductus arteriosus coils and Amplatzer duct occluders

Author keywords

Amplatzer duct occluder; Detachable coil; Patent ductus arteriosus

Indexed keywords

ADULT; AORTOGRAPHY; ARTICLE; BODY WEIGHT; CHILD; CONTROLLED STUDY; DEVICE; FLUOROSCOPY; FOLLOW UP; HUMAN; INFANT; MAJOR CLINICAL STUDY; PATENT DUCTUS ARTERIOSUS; PRIORITY JOURNAL; SURGICAL INSTRUMENT; THORAX RADIOGRAPHY;

EID: 0034109593     PISSN: 03406199     EISSN: None     Source Type: Journal    
DOI: 10.1007/s004310050073     Document Type: Article
Times cited : (32)

References (18)
  • 1
    • 0028092055 scopus 로고
    • Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
    • Hijazi ZM, Geggel RL (1994) Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am J Cardiol 74:925-929
    • (1994) Am J Cardiol , vol.74 , pp. 925-929
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 2
    • 0030478046 scopus 로고    scopus 로고
    • Transcatheter closure of large patent ductus arteriosus ( > 4 mm) with multiple Gianturco coils: Immediate and mid-term results
    • Hijazi ZM, Geggel RL (1996) Transcatheter closure of large patent ductus arteriosus ( > 4 mm) with multiple Gianturco coils: immediate and mid-term results. Heart 76:536-540
    • (1996) Heart , vol.76 , pp. 536-540
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 3
    • 0024558526 scopus 로고
    • Angiographie classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion
    • Krichenko A, Benson LN, Burrows P, Moes CAP, McLaughlin P, Freedom RM (1989) Angiographie classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 63:877-880
    • (1989) Am J Cardiol , vol.63 , pp. 877-880
    • Krichenko, A.1    Benson, L.N.2    Burrows, P.3    Moes, C.A.P.4    McLaughlin, P.5    Freedom, R.M.6
  • 5
    • 17444447441 scopus 로고    scopus 로고
    • Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results
    • Masura J, Walsh KP, Thanopoulous B, Chan C, Bass J, Goussous Y, Gavora P, Hijazi Z (1998) Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results. J Am Coll Cardiol 31:878-882
    • (1998) J Am Coll Cardiol , vol.31 , pp. 878-882
    • Masura, J.1    Walsh, K.P.2    Thanopoulous, B.3    Chan, C.4    Bass, J.5    Goussous, Y.6    Gavora, P.7    Hijazi, Z.8
  • 6
    • 0030836347 scopus 로고    scopus 로고
    • Percutaneous closure of patent ductus arteriosus using special screwing detachable coils
    • Podnar T, Masura J (1997) Percutaneous closure of patent ductus arteriosus using special screwing detachable coils. Cathet Cardiovasc Diagn 41:386-391
    • (1997) Cathet Cardiovasc Diagn , vol.41 , pp. 386-391
    • Podnar, T.1    Masura, J.2
  • 7
    • 0344820776 scopus 로고    scopus 로고
    • Transcatheter occlusion of residual patent ductus arteriosus after surgical ligation
    • Podnar T, Masura J (1999) Transcatheter occlusion of residual patent ductus arteriosus after surgical ligation. Pediatr Cardiol 20:126-130
    • (1999) Pediatr Cardiol , vol.20 , pp. 126-130
    • Podnar, T.1    Masura, J.2
  • 8
    • 0014079566 scopus 로고
    • Der Verschluss des Ductus arteriosus persistens ohne Thorakotomie
    • Porstmann W, Wierny L, Warnke H (1967) Der Verschluss des Ductus arteriosus persistens ohne Thorakotomie. Thoraxchirurgie 15:199-203
    • (1967) Thoraxchirurgie , vol.15 , pp. 199-203
    • Porstmann, W.1    Wierny, L.2    Warnke, H.3
  • 9
    • 0031885582 scopus 로고    scopus 로고
    • Current therapy of the patent ductus arteriosus
    • Radtke WAK (1998) Current therapy of the patent ductus arteriosus. Curr Opin Cardiol 13:59-65
    • (1998) Curr Opin Cardiol , vol.13 , pp. 59-65
    • Radtke, W.A.K.1
  • 10
    • 0027301293 scopus 로고
    • Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience
    • Rao PS, Sideris EB, Haddad J, Rey C, Hausdorf G, Wilson AD, Smith PA, Chopra PS (1993) Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience. Circulation 88:1119-1126
    • (1993) Circulation , vol.88 , pp. 1119-1126
    • Rao, P.S.1    Sideris, E.B.2    Haddad, J.3    Rey, C.4    Hausdorf, G.5    Wilson, A.D.6    Smith, P.A.7    Chopra, P.S.8
  • 11
    • 0023153198 scopus 로고
    • Nonsurgical closure of patent ductus arteriosus: Clinical application of Rashkind PDA occluder system
    • Rashkind WJ, Mullins CE, Hellebrand WE, Tait MA (1987) Nonsurgical closure of patent ductus arteriosus: clinical application of Rashkind PDA occluder system. Circulation 75: 583-592
    • (1987) Circulation , vol.75 , pp. 583-592
    • Rashkind, W.J.1    Mullins, C.E.2    Hellebrand, W.E.3    Tait, M.A.4
  • 12
    • 0030332463 scopus 로고    scopus 로고
    • Closure of the arterial duct: Past, present, and future
    • Rigby ML (1996) Closure of the arterial duct: past, present, and future. (editorial). Heart 76:461-462
    • (1996) Heart , vol.76 , pp. 461-462
    • Rigby, M.L.1
  • 13
    • 0030473809 scopus 로고    scopus 로고
    • Evolving use of embolisation coils for occlusion of the arterial duct
    • Rosenthal E, Qureshi SA, Reidy J, Baker EJ, Tynan M (1996) Evolving use of embolisation coils for occlusion of the arterial duct. Heart 76:525-530
    • (1996) Heart , vol.76 , pp. 525-530
    • Rosenthal, E.1    Qureshi, S.A.2    Reidy, J.3    Baker, E.J.4    Tynan, M.5
  • 17
    • 0029764568 scopus 로고    scopus 로고
    • Transcatheter occlusion of the arterial duct with Cook detachable coils: Early experience
    • Uzun O, Hancock S, Parsons JM, Dickinson DF, Gibbs JL (1996) Transcatheter occlusion of the arterial duct with Cook detachable coils: early experience. Heart 76:269-273
    • (1996) Heart , vol.76 , pp. 269-273
    • Uzun, O.1    Hancock, S.2    Parsons, J.M.3    Dickinson, D.F.4    Gibbs, J.L.5
  • 18
    • 0027423486 scopus 로고
    • Results of transcatheter closure of patent ductus arteriosus with the Botalloccluder
    • Verin VE, Saveliev SV, Kolody SM, Prokubovski VI (1993) Results of transcatheter closure of patent ductus arteriosus with the Botalloccluder. J Am Coll Cardiol 22:1509-1514
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1509-1514
    • Verin, V.E.1    Saveliev, S.V.2    Kolody, S.M.3    Prokubovski, V.I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.