메뉴 건너뛰기




Volumn 55, Issue 3, 2000, Pages 238-239

Interventional radiological retrieval of a guide-wire entrapped in a Greenfield filter - Treatment of an avoidable complication of central venous access procedure

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CASE REPORT; FILTER; FLUOROSCOPY; GUIDE WIRE; HUMAN; INFERIOR CAVA VEIN; INTRAVENOUS CATHETER; LUNG EMBOLISM; MALE; PEROPERATIVE COMPLICATION; PRIORITY JOURNAL;

EID: 0034104656     PISSN: 00099260     EISSN: None     Source Type: Journal    
DOI: 10.1053/crad.1999.0082     Document Type: Article
Times cited : (13)

References (8)
  • 1
    • 0028840044 scopus 로고
    • Comparative efficacy and complications of vena caval filters
    • Mohan CR, Hoballah JJ, Sharp WJ, et al. Comparative efficacy and complications of vena caval filters. J Vasc Surg 1995;21:235-246.
    • (1995) J Vasc Surg , vol.21 , pp. 235-246
    • Mohan, C.R.1    Hoballah, J.J.2    Sharp, W.J.3
  • 2
    • 0026252660 scopus 로고
    • Vena Tech vena cava filter: Experience and early follow-up
    • Taylor FC, Awh MH, Kahn CE, et al. Vena Tech vena cava filter: experience and early follow-up. J Vasc Intervent Radiol 1991;2:435-440.
    • (1991) J Vasc Intervent Radiol , vol.2 , pp. 435-440
    • Taylor, F.C.1    Awh, M.H.2    Kahn, C.E.3
  • 3
    • 0028217131 scopus 로고
    • An unusual complication of central venous catheterisation
    • Amesbury S, Vargish T, Hall J. An unusual complication of central venous catheterisation. Chest 1994;105:905-907.
    • (1994) Chest , vol.105 , pp. 905-907
    • Amesbury, S.1    Vargish, T.2    Hall, J.3
  • 4
    • 0030066659 scopus 로고    scopus 로고
    • Guide-wire entrapment by inferior vena caval filters: In vitro evaluation
    • Kaufman JA, Thomas JW, Geller SC, et al. Guide-wire entrapment by inferior vena caval filters: in vitro evaluation. Radiology 1996;198:71-76.
    • (1996) Radiology , vol.198 , pp. 71-76
    • Kaufman, J.A.1    Thomas, J.W.2    Geller, S.C.3
  • 5
    • 0027220378 scopus 로고
    • Dislodgment of inferior vena caval filters during 'blind' insertion of central venous catheters
    • Loesberg A, Taylor FC, Awh MH. Dislodgment of inferior vena caval filters during 'blind' insertion of central venous catheters. Am J Roentgenol 1993;161:637-638.
    • (1993) Am J Roentgenol , vol.161 , pp. 637-638
    • Loesberg, A.1    Taylor, F.C.2    Awh, M.H.3
  • 6
    • 0028075189 scopus 로고
    • Greenfield inferior vena cava filter dislodged during central venous catheter placement
    • Marelich GP, Tharratt RS. Greenfield inferior vena cava filter dislodged during central venous catheter placement. Chest 1994;106:957-959.
    • (1994) Chest , vol.106 , pp. 957-959
    • Marelich, G.P.1    Tharratt, R.S.2
  • 7
    • 0022487110 scopus 로고
    • Migration of a Greenfield filter to the pulmonary artery: A case report
    • Friedell ML, Goldenkranz RJ, Parsonnet V, et al. Migration of a Greenfield filter to the pulmonary artery: a case report. J Vasc Surg 1986;3:929-931.
    • (1986) J Vasc Surg , vol.3 , pp. 929-931
    • Friedell, M.L.1    Goldenkranz, R.J.2    Parsonnet, V.3
  • 8
    • 0023801469 scopus 로고
    • Percutaneous removal of intracardiac Greenfield vena cava filter
    • Deutsch L-S. Percutaneous removal of intracardiac Greenfield vena cava filter. Am J Roentgenol 1988;151:677-679.
    • (1988) Am J Roentgenol , vol.151 , pp. 677-679
    • Deutsch, L.-S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.