Volumn 15, Issue 3, 2000, Pages 566-569

In vitro assessment of an ultrasonic flowmeter for use in ventilated infants

Author keywords

In vitro assessment; Infant; Mechanical ventilation; Tidal volume measurement; Ultrasonic flowmeter

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; CHILD CARE; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; FLOWMETER; HUMIDITY; INTENSIVE CARE; OXYGEN CONCENTRATION; PATIENT MONITORING; PNEUMOTACHYGRAPHY; PRIORITY JOURNAL; RESPIRATORY AIRFLOW; TIDAL VOLUME; ULTRASOUND;

EID: 0034103567     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-3003.2000.15.23.x     Document Type: Article
Times cited : (13)

References (9)
  • 2
    • 0028420258 scopus 로고
    • Einfluss der physikalischen eigenschaften des atemgases auf die pneumotachographische ventilationsmessung bei neugeborenen
    • Foitzik B, Schmalisch G, Wauer RR. Einfluss der physikalischen Eigenschaften des Atemgases auf die pneumotachographische Ventilationsmessung bei Neugeborenen. Biomed Tech (Berl) 1994; 39: 85-92.
    • (1994) Biomed Tech (Berl) , vol.39 , pp. 85-92
    • Foitzik, B.1    Schmalisch, G.2    Wauer, R.R.3
  • 3
  • 4
    • 0019225909 scopus 로고
    • Ultrasonic measurement of respiratory flow
    • Plaut DI, Webster JG. Ultrasonic measurement of respiratory flow. IEEE Trans Biomed Eng 1980; 27: 549-558.
    • (1980) IEEE Trans Biomed Eng , vol.27 , pp. 549-558
    • Plaut, D.I.1    Webster, J.G.2
  • 7
    • 0018634866 scopus 로고
    • A technique for measuring frequency response of pressure, volume, and flow transducers
    • Jackson AC, Vinegar A. A technique for measuring frequency response of pressure, volume, and flow transducers. J Appl Physiol 1979; 47: 462-467.
    • (1979) J Appl Physiol , vol.47 , pp. 462-467
    • Jackson, A.C.1    Vinegar, A.2
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 0003012753 scopus 로고    scopus 로고
    • Equipment requirements for infant respiratory function testing
    • Stocks J, Sly PD, Tepper RS, Morgan WJ, eds New York, Wiley-Liss
    • Sly PD, Davis GM. Equipment requirements for infant respiratory function testing. In: Stocks J, Sly PD, Tepper RS, Morgan WJ, eds. Infant Respiratory Function Testing. 1st Edn. New York, Wiley-Liss, 1996; pp. 45-80.
    • (1996) Infant Respiratory Function Testing. 1st Edn. , pp. 45-80
    • Sly, P.D.1    Davis, G.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.