-
1
-
-
0010489706
-
Peritoneal transport evaluation in CAPD
-
Moncrief JW, Popovich RP, eds. New York: Masson
-
Pyle WK, Moncrief JW, Popovich RP. Peritoneal transport evaluation in CAPD. In: Moncrief JW, Popovich RP, eds. CAPD update, continuous ambulatory peritoneal dialysis. New York: Masson; 1980: 35-52.
-
(1980)
CAPD Update, Continuous Ambulatory Peritoneal Dialysis
, pp. 35-52
-
-
Pyle, W.K.1
Moncrief, J.W.2
Popovich, R.P.3
-
2
-
-
0027249571
-
A three-pore model of peritoneal transport
-
Rippe B. A three-pore model of peritoneal transport. Perit Dial Int 1993; 13(Suppl 2):S35-8.
-
(1993)
Perit Dial Int
, vol.13
, Issue.SUPPL. 2
-
-
Rippe, B.1
-
3
-
-
0026320125
-
Kinetic modelling as a prescription aid in peritoneal dialysis
-
Vonesh EF, Lysaght MJ, Moran J, Farrell P. Kinetic modelling as a prescription aid in peritoneal dialysis. Blood Purif 1991; 9:246-70.
-
(1991)
Blood Purif
, vol.9
, pp. 246-270
-
-
Vonesh, E.F.1
Lysaght, M.J.2
Moran, J.3
Farrell, P.4
-
4
-
-
0025260830
-
A distributed model of fluid and mass transfer in peritoneal dialysis
-
Seames EL, Moncrief JW, Popovich RP. A distributed model of fluid and mass transfer in peritoneal dialysis. Am J Physiol 1990; 258:R958-72.
-
(1990)
Am J Physiol
, vol.258
-
-
Seames, E.L.1
Moncrief, J.W.2
Popovich, R.P.3
-
5
-
-
0001322462
-
Automated peritoneal dialysis
-
Gokal R, Nolph KD, eds. Dordrecht: Kluwer Academic Publishers
-
Diaz-Buxo JA, Suki WN. Automated peritoneal dialysis. In: Gokal R, Nolph KD, eds. The textbook of peritoneal dialysis. Dordrecht: Kluwer Academic Publishers; 1994: 399-418.
-
(1994)
The Textbook of Peritoneal Dialysis
, pp. 399-418
-
-
Diaz-Buxo, J.A.1
Suki, W.N.2
-
6
-
-
0032615326
-
Automated peritoneal dialysis. A therapy in evolution
-
Diaz-Buxo J. Automated peritoneal dialysis. A therapy in evolution. Contrib Nephrol 1999; 129:1-14.
-
(1999)
Contrib Nephrol
, vol.129
, pp. 1-14
-
-
Diaz-Buxo, J.1
-
7
-
-
10544247322
-
Recommended clinical practices for maximizing peritoneal dialysis clearances
-
Blake P, Burkart JM, Churchill DN, Daugirdas J, Depner T, Hamburger RJ, et al. Recommended clinical practices for maximizing peritoneal dialysis clearances. Perit Dial Int 1996; 16:448-56.
-
(1996)
Perit Dial Int
, vol.16
, pp. 448-456
-
-
Blake, P.1
Burkart, J.M.2
Churchill, D.N.3
Daugirdas, J.4
Depner, T.5
Hamburger, R.J.6
-
8
-
-
0003174870
-
Clinical practice guidelines for peritoneal dialysis adequacy. V. Adequate dose of peritoneal dialysis
-
National Kidney Foundation Dialysis Outcomes Quality Initiative. Clinical practice guidelines for peritoneal dialysis adequacy. V. Adequate dose of peritoneal dialysis. Am J Kidney Dis 1997; 30(Suppl 2):S86-92.
-
(1997)
Am J Kidney Dis
, vol.30
, Issue.SUPPL. 2
-
-
-
9
-
-
0029941739
-
Peritoneal blood flow: Does it matter?
-
Ronco C, Feriani M, Chiaramonte S, Brendolan A, Milan M, LaGreca G. Peritoneal blood flow: Does it matter? Perit Dial Int 1996; 16(Suppl 1):S70-5.
-
(1996)
Perit Dial Int
, vol.16
, Issue.SUPPL. 1
-
-
Ronco, C.1
Feriani, M.2
Chiaramonte, S.3
Brendolan, A.4
Milan, M.5
LaGreca, G.6
-
10
-
-
0021019399
-
A simple kinetic model for assessing peritoneal mass transfer in chronic ambulatory peritoneal dialysis
-
Garred LJ, Canaud B, Farrell PC. A simple kinetic model for assessing peritoneal mass transfer in chronic ambulatory peritoneal dialysis. ASAIO J 1983; 6:131-7.
-
(1983)
ASAIO J
, vol.6
, pp. 131-137
-
-
Garred, L.J.1
Canaud, B.2
Farrell, P.C.3
-
11
-
-
0026138174
-
A comparative analysis of mass transport models in peritoneal dialysis
-
Waniewski J, Werynski A, Heimbürger O, Lindholm B. A comparative analysis of mass transport models in peritoneal dialysis. ASAIO Trans 1991; 37:65-75.
-
(1991)
ASAIO Trans
, vol.37
, pp. 65-75
-
-
Waniewski, J.1
Werynski, A.2
Heimbürger, O.3
Lindholm, B.4
-
12
-
-
0032621405
-
Role of drain and fill profile in automated peritoneal dialysis
-
Amici G, Thomaseth K. Role of drain and fill profile in automated peritoneal dialysis. Coutrib Nephrol 1999; 129:44-53.
-
(1999)
Coutrib Nephrol
, vol.129
, pp. 44-53
-
-
Amici, G.1
Thomaseth, K.2
-
13
-
-
0028418757
-
Relationship between body size, fill volume, and mass transfer area coefficient in peritoneal dialysis
-
Keshaviah P, Emerson PF, Vonesh EF, Brandes JC. Relationship between body size, fill volume, and mass transfer area coefficient in peritoneal dialysis. J Am Soc Nephrol 1994; 4:1820-6.
-
(1994)
J Am Soc Nephrol
, vol.4
, pp. 1820-1826
-
-
Keshaviah, P.1
Emerson, P.F.2
Vonesh, E.F.3
Brandes, J.C.4
-
14
-
-
0028941028
-
Optimization of dialysate flow and mass transfer during automated peritoneal dialysis
-
Brandes JC, Packard WJ, Watters SK, Fritsche C. Optimization of dialysate flow and mass transfer during automated peritoneal dialysis. Am J Kidney Dis 1995; 25:603-10.
-
(1995)
Am J Kidney Dis
, vol.25
, pp. 603-610
-
-
Brandes, J.C.1
Packard, W.J.2
Watters, S.K.3
Fritsche, C.4
-
15
-
-
0342842313
-
Analysis of the drain flow rates in supine position measured by continuous data acquisition
-
Durand PY, Balteau P, Chanliau J, Kessler M. Analysis of the drain flow rates in supine position measured by continuous data acquisition [Abstract]. Perit Dial Int 1998; 18:122.
-
(1998)
Perit Dial Int
, vol.18
, pp. 122
-
-
Durand, P.Y.1
Balteau, P.2
Chanliau, J.3
Kessler, M.4
-
16
-
-
0024582188
-
Clinical value of standardized equilibration tests in CAPD patients
-
Twardowski ZJ. Clinical value of standardized equilibration tests in CAPD patients. Blood Purif 1989; 7:95-108.
-
(1989)
Blood Purif
, vol.7
, pp. 95-108
-
-
Twardowski, Z.J.1
-
17
-
-
0032622447
-
Continuous cyclic peritoneal dialysis prescription and power
-
Freida P, Issad B. Continuous cyclic peritoneal dialysis prescription and power. Contrib Nephrol 1999; 129:98-108.
-
(1999)
Contrib Nephrol
, vol.129
, pp. 98-108
-
-
Freida, P.1
Issad, B.2
-
18
-
-
0033372251
-
Automated peritoneal dialysis: When and how to do it
-
Amici G, Virga G, Ronco C. Automated peritoneal dialysis: When and how to do it. Perit Dial Int 1999; 19(Suppl 2):S115-20.
-
(1999)
Perit Dial Int
, vol.19
, Issue.SUPPL. 2
-
-
Amici, G.1
Virga, G.2
Ronco, C.3
-
19
-
-
0032622312
-
Patient selection for automated peritoneal dialysis on the basis of peritoneal transport characteristics
-
Churchill DN. Patient selection for automated peritoneal dialysis on the basis of peritoneal transport characteristics. Contrib Nephrol 1999; 129:69-74.
-
(1999)
Contrib Nephrol
, vol.129
, pp. 69-74
-
-
Churchill, D.N.1
-
20
-
-
0032608620
-
Membrane transport models and computerized kinetic modelling applied to automated peritoneal dialysis
-
Vonesh EF. Membrane transport models and computerized kinetic modelling applied to automated peritoneal dialysis. Contrib Nephrol 1999; 129:15-34.
-
(1999)
Contrib Nephrol
, vol.129
, pp. 15-34
-
-
Vonesh, E.F.1
-
21
-
-
0032608447
-
Three-pore model applied to automated peritoneal dialysis
-
Haraldsson B. Three-pore model applied to automated peritoneal dialysis. Contrib Nephrol 1999; 129:35-43.
-
(1999)
Contrib Nephrol
, vol.129
, pp. 35-43
-
-
Haraldsson, B.1
|