메뉴 건너뛰기




Volumn 3, Issue 1, 2000, Pages 43-48

Quantitative ultrasound of the calcaneus: An in vivo comparison with dual-energy X-ray absorptiometry and magnetic resonance imaging

Author keywords

Bone mineral density; Broad band ultrasound attenuation; Magnetic resonance imaging; Quantitative ultrasound of the calcaneus; Speed of sound

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; CALCANEUS; CONTROLLED STUDY; CORRELATION FUNCTION; DIAGNOSTIC ACCURACY; DUAL ENERGY X RAY ABSORPTIOMETRY; ECHOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; INTERMETHOD COMPARISON; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTMENOPAUSE; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS;

EID: 0034095310     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1385/JCD:3:1:043     Document Type: Article
Times cited : (7)

References (25)
  • 1
    • 0030934837 scopus 로고    scopus 로고
    • Bone ultrasound predicts fracture strongly and independently of densitometry in older women: A prospective study
    • 1. Bauer D, Glüer C, Cauley J, Vogt T, Ensrud K, Genant HK. 1997 Bone ultrasound predicts fracture strongly and independently of densitometry in older women: a prospective study. Arch Intern Med 157:629-634.
    • (1997) Arch Intern Med , vol.157 , pp. 629-634
    • Bauer, D.1    Glüer, C.2    Cauley, J.3    Vogt, T.4    Ensrud, K.5    Genant, H.K.6
  • 2
    • 16044362010 scopus 로고    scopus 로고
    • Ultrasonographic heel measurements to predict hip fracture in elderly women
    • 2. Hans D, Dargent-Molina O, Schott A, et al. 1996 Ultrasonographic heel measurements to predict hip fracture in elderly women. Lancet 348:511-514.
    • (1996) Lancet , vol.348 , pp. 511-514
    • Hans, D.1    Dargent-Molina, O.2    Schott, A.3
  • 3
    • 0030741752 scopus 로고    scopus 로고
    • Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA
    • 3. Chappard C, Laugier P, Fournier B, Roux C, Berger C. 1997 Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA. Osteoporos Int 7:316-322.
    • (1997) Osteoporos Int , vol.7 , pp. 316-322
    • Chappard, C.1    Laugier, P.2    Fournier, B.3    Roux, C.4    Berger, C.5
  • 4
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography
    • 4. Laugier P, Droin P, Laval-Jeantet A-M, Berger C. 1997 In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography. Bone 20:157-165.
    • (1997) Bone , vol.20 , pp. 157-165
    • Laugier, P.1    Droin, P.2    Laval-Jeantet, A.-M.3    Berger, C.4
  • 5
    • 0031397415 scopus 로고    scopus 로고
    • In vivo comparison of MR phase distribution and 1/T2* with morphometric parameters in the distal radius
    • 5. Allein S, Majumdar S, De Bisschop E, Newitt D, Luypaert R, Eisendrath H. 1997 In vivo comparison of MR phase distribution and 1/T2* with morphometric parameters in the distal radius. JMRI 7:389-393.
    • (1997) JMRI , vol.7 , pp. 389-393
    • Allein, S.1    Majumdar, S.2    De Bisschop, E.3    Newitt, D.4    Luypaert, R.5    Eisendrath, H.6
  • 6
    • 0025730177 scopus 로고
    • Trabeculur structure: Preliminary application of MR interferometry
    • 6. Wehrli F, Ford J, Attie M, Kressel H, Kaplan F. 1991 Trabeculur structure: preliminary application of MR interferometry. Radiology 179:615-621.
    • (1991) Radiology , vol.179 , pp. 615-621
    • Wehrli, F.1    Ford, J.2    Attie, M.3    Kressel, H.4    Kaplan, F.5
  • 7
    • 0028910958 scopus 로고
    • A review of the recent advances in magnetic resonance imaging in the assessment of osteoporosis
    • 7. Majumdar S, Genant HK. 1995 A review of the recent advances in magnetic resonance imaging in the assessment of osteoporosis. Osteoporos Int 5:79-92.
    • (1995) Osteoporos Int , vol.5 , pp. 79-92
    • Majumdar, S.1    Genant, H.K.2
  • 8
    • 0027377117 scopus 로고
    • Relationship between NMR transverse relaxation, trabecular bone architecture, and strength
    • 8. Chung H, Wehrli F, Williams J, Kugelmass S. 1993 Relationship between NMR transverse relaxation, trabecular bone architecture, and strength. Proc Natl Acad Sci USA 90:10250-10254.
    • (1993) Proc Natl Acad Sci USA , vol.90 , pp. 10250-10254
    • Chung, H.1    Wehrli, F.2    Williams, J.3    Kugelmass, S.4
  • 9
    • 0027204802 scopus 로고
    • Broadband ultrasound attenuation signals depend on trabecular orientation: An in vitro study
    • 9. Glüer C, Wu C, Genant HK. 1993 Broadband ultrasound attenuation signals depend on trabecular orientation: an in vitro study. Osteoporos Int 3:185-191.
    • (1993) Osteoporos Int , vol.3 , pp. 185-191
    • Glüer, C.1    Wu, C.2    Genant, H.K.3
  • 11
    • 0030858059 scopus 로고    scopus 로고
    • The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro
    • 11. Hodgskinson R, Njeh C, Currey J, Langton C. 1997 The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro. Bone 21:183-190.
    • (1997) Bone , vol.21 , pp. 183-190
    • Hodgskinson, R.1    Njeh, C.2    Currey, J.3    Langton, C.4
  • 12
    • 0029151174 scopus 로고
    • Do ultrasound measurements on the os calcis reflect more the bone microarchitecture than the bone mass? A two demensional histomorphometric study
    • 12. Hans D, Arlot M, Schott A, Roux J, Kotzki P, Meunier P. 1995 Do ultrasound measurements on the os calcis reflect more the bone microarchitecture than the bone mass? A two demensional histomorphometric study. Bone 16:295-300.
    • (1995) Bone , vol.16 , pp. 295-300
    • Hans, D.1    Arlot, M.2    Schott, A.3    Roux, J.4    Kotzki, P.5    Meunier, P.6
  • 13
    • 0028082374 scopus 로고
    • Broadband ultrasonic attenuation imaging: A new imaging technique of the os calcis
    • 13. Laugier P, Giat P, Berger G. 1994 Broadband ultrasonic attenuation imaging: a new imaging technique of the os calcis. Calcif Tissue Int 54:83-86.
    • (1994) Calcif Tissue Int , vol.54 , pp. 83-86
    • Laugier, P.1    Giat, P.2    Berger, G.3
  • 15
    • 0345164389 scopus 로고    scopus 로고
    • Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone
    • 15. Nicholson P, Müller R, Lowet G, et al. 1998 Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone. Bone 23:425-431.
    • (1998) Bone , vol.23 , pp. 425-431
    • Nicholson, P.1    Müller, R.2    Lowet, G.3
  • 16
    • 0028867759 scopus 로고
    • Evaluation of technical factors affecting the quantification of trabecular bone structure using magnetic resonance imaging
    • 16. Majumdar S, Newitt D, Jergas M, et al. 1995 Evaluation of technical factors affecting the quantification of trabecular bone structure using magnetic resonance imaging. Bone 17:417-430.
    • (1995) Bone , vol.17 , pp. 417-430
    • Majumdar, S.1    Newitt, D.2    Jergas, M.3
  • 17
    • 0025216842 scopus 로고
    • Evaluation of the susceptibility effect on the pase images of a simple gradient echo
    • 17. Yamada N, Imakita S, Sakama T, et al. 1990 Evaluation of the susceptibility effect on the pase images of a simple gradient echo. Radiology 175:561-565.
    • (1990) Radiology , vol.175 , pp. 561-565
    • Yamada, N.1    Imakita, S.2    Sakama, T.3
  • 18
    • 0030026734 scopus 로고    scopus 로고
    • Quantification of trabecular structure in the distal femur using magnetic resonance phase imaging
    • 18. De Bisschop E, Luypaert R, Allein S, Osteaux M. 1996 Quantification of trabecular structure in the distal femur using magnetic resonance phase imaging. Magn Reson Imaging 14:11-20.
    • (1996) Magn Reson Imaging , vol.14 , pp. 11-20
    • De Bisschop, E.1    Luypaert, R.2    Allein, S.3    Osteaux, M.4
  • 19
    • 0031032218 scopus 로고    scopus 로고
    • High resolution magnetic resonance imaging of the calcaneus: Age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements
    • 19. Ouyang X, Selbry K, Lang P, et al. 1997 High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements. Calcif Tissue Int 60:139-147.
    • (1997) Calcif Tissue Int , vol.60 , pp. 139-147
    • Ouyang, X.1    Selbry, K.2    Lang, P.3
  • 20
    • 0030857684 scopus 로고    scopus 로고
    • Improved reproducibility of broadband ultrasound attenuation of the os calcis by using a specific region of interest
    • 20. Jørgensen HL, Hassager C. 1997 Improved reproducibility of broadband ultrasound attenuation of the os calcis by using a specific region of interest. Bone 21:109-112.
    • (1997) Bone , vol.21 , pp. 109-112
    • Jørgensen, H.L.1    Hassager, C.2
  • 21
    • 0031909571 scopus 로고    scopus 로고
    • Heterogeneity of trabecular bone structure in the calcaneus using magnetic resonance imaging
    • 21. Lin JC, Amling M, Newitt DC, Selby R, Srivastov SK, Delling G, et al. 1998 Heterogeneity of trabecular bone structure in the calcaneus using magnetic resonance imaging. Osteoporos Int 8:16-24.
    • (1998) Osteoporos Int , vol.8 , pp. 16-24
    • Lin, J.C.1    Amling, M.2    Newitt, D.C.3    Selby, R.4    Srivastov, S.K.5    Delling, G.6
  • 22
    • 0029779557 scopus 로고    scopus 로고
    • Broadband ultrasound imaging: A new imaging method in osteoporosis
    • 22. Roux C, Fournier P, Laugier P, et al. 1996 Broadband ultrasound imaging: a new imaging method in osteoporosis. J Bone Miner Res 11:1112-1118.
    • (1996) J Bone Miner Res , vol.11 , pp. 1112-1118
    • Roux, C.1    Fournier, P.2    Laugier, P.3
  • 23
    • 0030058289 scopus 로고    scopus 로고
    • Distal radius: In vivo assessment with quantitative MR imaging, peripheral quantitative CT, and dual X-ray absorptiometry
    • 23. Grampp S, Majumdar S, Jergas M, Newitt D, Lang P, Genant HK. 1996 Distal radius: in vivo assessment with quantitative MR imaging, peripheral quantitative CT, and dual X-ray absorptiometry. Radiology 198:213-218.
    • (1996) Radiology , vol.198 , pp. 213-218
    • Grampp, S.1    Majumdar, S.2    Jergas, M.3    Newitt, D.4    Lang, P.5    Genant, H.K.6
  • 25
    • 1842406059 scopus 로고    scopus 로고
    • Bone densitometry: Current status and future prospects
    • 25. Blake GM, Güer CC, Fogelman I. 1997 Bone densitometry: current status and future prospects. Br J Radiol 70:S177.
    • (1997) Br J Radiol , vol.70
    • Blake, G.M.1    Güer, C.C.2    Fogelman, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.