메뉴 건너뛰기




Volumn 26, Issue 4, 2000, Pages 593-602

Using Doppler signal power to detect changes in vessel size: A feasibility study using a wall-less flow phantom

Author keywords

Beam shape; Doppler signal power; Filtering; Flow phantom; Transcranial Doppler ultrasound

Indexed keywords

BLOOD; BLOOD VESSELS; COMPUTATIONAL METHODS; DOPPLER EFFECT; TISSUE; ULTRASONIC TRANSDUCERS; ULTRASONIC WAVES;

EID: 0034087178     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00148-9     Document Type: Article
Times cited : (7)

References (46)
  • 1
    • 0023226901 scopus 로고
    • Visually evoked dynamic blood flow response of the human cerebral circulation
    • Aaslid R. Visually evoked dynamic blood flow response of the human cerebral circulation. Stroke. 18:1987;771-775.
    • (1987) Stroke , vol.18 , pp. 771-775
    • Aaslid, R.1
  • 3
    • 0025776907 scopus 로고
    • Assessment of cerebral autoregulation dynamics from simultaneous arterial and venous transcranial Doppler recordings in humans
    • Aaslid R., Newell D.W., Stoss R., Sorteberg W., Lindegaard K.F. Assessment of cerebral autoregulation dynamics from simultaneous arterial and venous transcranial Doppler recordings in humans. Stroke. 22:1991;1148-1154.
    • (1991) Stroke , vol.22 , pp. 1148-1154
    • Aaslid, R.1    Newell, D.W.2    Stoss, R.3    Sorteberg, W.4    Lindegaard, K.F.5
  • 4
    • 0015250531 scopus 로고
    • On the instantaneous measurement of blood flow by ultrasonic means
    • Arts M.G.J., Roevros J.M.J.G. On the instantaneous measurement of blood flow by ultrasonic means. Med Biol Eng Comput. 10:1972;23-34.
    • (1972) Med Biol Eng Comput , vol.10 , pp. 23-34
    • Arts, M.G.J.1    Roevros, J.M.J.G.2
  • 5
    • 0021091269 scopus 로고
    • Regional cerebral blood flow, cerebral blood velocity, and pulsatility index in newborn dogs
    • Batton D.G., Hellmann J., Hernandez M.J., Maisels M.J. Regional cerebral blood flow, cerebral blood velocity, and pulsatility index in newborn dogs. Pediatr Res. 17:1983;908-912.
    • (1983) Pediatr Res , vol.17 , pp. 908-912
    • Batton, D.G.1    Hellmann, J.2    Hernandez, M.J.3    Maisels, M.J.4
  • 6
    • 0022449467 scopus 로고
    • Transcranial Doppler measurement of middle cerebral artery blood flow velocity: A validation study
    • Bishop C.C.R., Powell S., Rutt D., Browse N.L. Transcranial Doppler measurement of middle cerebral artery blood flow velocity A validation study . Stroke. 17:1986;913-915.
    • (1986) Stroke , vol.17 , pp. 913-915
    • Bishop, C.C.R.1    Powell, S.2    Rutt, D.3    Browse, N.L.4
  • 7
    • 0034018484 scopus 로고    scopus 로고
    • The effects of beam shape on the ability to predict changes in vessel size from Doppler signal power
    • (in press)
    • Deverson S, Evans DH. The effects of beam shape on the ability to predict changes in vessel size from Doppler signal power. Ultrasound Med Biol (in press).
    • Ultrasound Med Biol
    • Deverson, S.1    Evans, D.H.2
  • 8
    • 0034057780 scopus 로고    scopus 로고
    • The effects of temporal bone on transcranial Doppler ultrasound beam shape
    • Deverson S., Evans D.H., Bouch D.C. The effects of temporal bone on transcranial Doppler ultrasound beam shape. Ultrasound Med Biol. 26:1999;239-244.
    • (1999) Ultrasound Med Biol , vol.26 , pp. 239-244
    • Deverson, S.1    Evans, D.H.2    Bouch, D.C.3
  • 9
    • 0024058906 scopus 로고
    • A pulse-foot-seeking algorithm for Doppler ultrasound waveforms
    • Evans D.H. A pulse-foot-seeking algorithm for Doppler ultrasound waveforms. Clin Phys Physiol Meas. 9:1988;267-271.
    • (1988) Clin Phys Physiol Meas , vol.9 , pp. 267-271
    • Evans, D.H.1
  • 12
    • 0017964432 scopus 로고
    • Acoustical properties of the human skull
    • Fry F.J., Barger J.E. Acoustical properties of the human skull. J Acoust Soc Am. 63:1978;1576-1590.
    • (1978) J Acoust Soc Am , vol.63 , pp. 1576-1590
    • Fry, F.J.1    Barger, J.E.2
  • 13
    • 0021322915 scopus 로고
    • Cerebral blood flow in the newborn infant: Comparison of Doppler ultrasound and 133-Xe clearance
    • Greisen G., Johansen K., Ellison P.H., Fredriksen P.S., Mali J., Friis-Hansen B. Cerebral blood flow in the newborn infant comparison of Doppler ultrasound and 133-Xe clearance . J Pediatr. 104:1984;411-418.
    • (1984) J Pediatr , vol.104 , pp. 411-418
    • Greisen, G.1    Johansen, K.2    Ellison, P.H.3    Fredriksen, P.S.4    Mali, J.5    Friis-Hansen, B.6
  • 14
    • 0002143429 scopus 로고
    • Transmission of ultrasound through the temporal bone
    • R. Aaslid. New York: Springer-Verlag
    • Grolimund P. Transmission of ultrasound through the temporal bone. Aaslid R. Transcranial Doppler sonography. 1986;10-21 Springer-Verlag, New York.
    • (1986) Transcranial Doppler Sonography , pp. 10-21
    • Grolimund, P.1
  • 15
    • 0027997533 scopus 로고
    • Simultaneous measurements of cerebral circulation with electromagnetic flowmetry and Doppler ultrasound velocity in the newborn pig
    • Haaland K., Karlsson B., Skovlund E., Thoresen M. Simultaneous measurements of cerebral circulation with electromagnetic flowmetry and Doppler ultrasound velocity in the newborn pig. Pediatr Res. 36:1994;601-606.
    • (1994) Pediatr Res , vol.36 , pp. 601-606
    • Haaland, K.1    Karlsson, B.2    Skovlund, E.3    Thoresen, M.4
  • 16
    • 0020626814 scopus 로고
    • Validity of Doppler measurements of anterior cerebral artery blood flow velocity: Correlation with brain blood flow in piglets
    • Hansen N.B., Stonestreet B.S., Rosenkrantz T.S., Oh W. Validity of Doppler measurements of anterior cerebral artery blood flow velocity correlation with brain blood flow in piglets . Pediatrics. 72:1983;526-531.
    • (1983) Pediatrics , vol.72 , pp. 526-531
    • Hansen, N.B.1    Stonestreet, B.S.2    Rosenkrantz, T.S.3    Oh, W.4
  • 17
    • 0011158207 scopus 로고
    • Influence of various factors on the Doppler flow index measured in a flow model
    • Harer C., Widder B., Klemm P. Influence of various factors on the Doppler flow index measured in a flow model. J Neuroimaging. 5:1995;s86.
    • (1995) J Neuroimaging , vol.5 , pp. 86
    • Harer, C.1    Widder, B.2    Klemm, P.3
  • 18
    • 0030924153 scopus 로고    scopus 로고
    • Evaluation of cerebral arterial flow with transcranial Doppler ultrasound: Theoretical development and phantom studies
    • Hatab M.R., Giller C.A., Clarke G.D. Evaluation of cerebral arterial flow with transcranial Doppler ultrasound theoretical development and phantom studies . Ultrasound Med Biol. 23:1997;1025-1031.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 1025-1031
    • Hatab, M.R.1    Giller, C.A.2    Clarke, G.D.3
  • 19
    • 0024546198 scopus 로고
    • Validity of cerebral arterial blood flow calculations from velocity measurements
    • Kontos H.A. Validity of cerebral arterial blood flow calculations from velocity measurements. Stroke. 20:1989;1-3.
    • (1989) Stroke , vol.20 , pp. 1-3
    • Kontos, H.A.1
  • 20
    • 0027978479 scopus 로고
    • Transcranial Doppler is valid for determination of the lower limit of cerebral blood flow autoregulation
    • Larsen F.S., Olsen K.S., Hansen B.A., Paulson O.B., Knudsen G.M. Transcranial Doppler is valid for determination of the lower limit of cerebral blood flow autoregulation. Stroke. 25:1994;1985-1988.
    • (1994) Stroke , vol.25 , pp. 1985-1988
    • Larsen, F.S.1    Olsen, K.S.2    Hansen, B.A.3    Paulson, O.B.4    Knudsen, G.M.5
  • 21
    • 0023572004 scopus 로고
    • Variations in middle cerebral artery blood flow investigated with noninvasive transcranial blood velocity measurements
    • Lindegaard K.F., Lundar T., Wiberg J., Sjoberg D., Aaslid R., Nornes H. Variations in middle cerebral artery blood flow investigated with noninvasive transcranial blood velocity measurements. Stroke. 18:1987;1025-1030.
    • (1987) Stroke , vol.18 , pp. 1025-1030
    • Lindegaard, K.F.1    Lundar, T.2    Wiberg, J.3    Sjoberg, D.4    Aaslid, R.5    Nornes, H.6
  • 22
    • 0022842285 scopus 로고
    • Intracranial Doppler Flow velocimetry compared with extracranial carotid blood flow measurements
    • Lundell B.P.W., Kennedy K.A., Lindstrom D.P., Sundell H., Stahlman M.T. Intracranial Doppler Flow velocimetry compared with extracranial carotid blood flow measurements. Acta Paediatr Scand. 329:1986;127-133.
    • (1986) Acta Paediatr Scand , vol.329 , pp. 127-133
    • Lundell, B.P.W.1    Kennedy, K.A.2    Lindstrom, D.P.3    Sundell, H.4    Stahlman, M.T.5
  • 23
    • 0028936398 scopus 로고
    • Measurement of blood flow velocity in the basal cerebral circulation: Advantages of transcranial colour-coded sonography over conventional transcranial Doppler
    • Martin P.J., Evans D.H., Naylor A.R. Measurement of blood flow velocity in the basal cerebral circulation advantages of transcranial colour-coded sonography over conventional transcranial Doppler . J Clin Ultrasound. 23:1995;21-26.
    • (1995) J Clin Ultrasound , vol.23 , pp. 21-26
    • Martin, P.J.1    Evans, D.H.2    Naylor, A.R.3
  • 24
    • 0027756983 scopus 로고
    • Transcranial colour coded sonography as an aid to measurement of blood flow velocity in the basal cerebral arteries
    • Martin P.J., Evans D.H., Naylor A.R., Bell P.R.F. Transcranial colour coded sonography as an aid to measurement of blood flow velocity in the basal cerebral arteries. Ultrasound Med Biol. 19:1993;711-716.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 711-716
    • Martin, P.J.1    Evans, D.H.2    Naylor, A.R.3    Bell, P.R.F.4
  • 26
    • 0342444564 scopus 로고
    • Regional cerebral blood flow and Doppler flow velocity in the middle cerebral artery of the cat
    • Morris P.J., Rennie J., Evans D.H., Levene M.I. Regional cerebral blood flow and Doppler flow velocity in the middle cerebral artery of the cat. Br J Anaesth. 63:1989;233-234.
    • (1989) Br J Anaesth , vol.63 , pp. 233-234
    • Morris, P.J.1    Rennie, J.2    Evans, D.H.3    Levene, M.I.4
  • 28
    • 0028352909 scopus 로고
    • Flow and velocity during autoregulation testing in humans
    • Muller H.R. Flow and velocity during autoregulation testing in humans. Stroke. 25:1994;1296-1297.
    • (1994) Stroke , vol.25 , pp. 1296-1297
    • Muller, H.R.1
  • 29
    • 0002357011 scopus 로고
    • Response of middle cerebral artery volume flow to orthostasis
    • Muller H.R., Casty M., Moll R., Zehnder R. Response of middle cerebral artery volume flow to orthostasis. Cerebrovasc Dis. 1:1991;82-89.
    • (1991) Cerebrovasc Dis , vol.1 , pp. 82-89
    • Muller, H.R.1    Casty, M.2    Moll, R.3    Zehnder, R.4
  • 30
    • 0028343750 scopus 로고
    • Comparison of flow and velocity during dynamic autoregulation testing in humans
    • Newell D.W., Aaslid R., Lam A.M., Mayberg T.S., Winn H.R. Comparison of flow and velocity during dynamic autoregulation testing in humans. Stroke. 25:1994;793-797.
    • (1994) Stroke , vol.25 , pp. 793-797
    • Newell, D.W.1    Aaslid, R.2    Lam, A.M.3    Mayberg, T.S.4    Winn, H.R.5
  • 31
    • 0030455702 scopus 로고    scopus 로고
    • Indexes of flow and cross-sectional area of the middle cerebral artery using Doppler ultrasound during hypoxia and hypercapnia in humans
    • Poulin M.J., Robbins P.A. Indexes of flow and cross-sectional area of the middle cerebral artery using Doppler ultrasound during hypoxia and hypercapnia in humans. Stroke. 27:1996;2244-2250.
    • (1996) Stroke , vol.27 , pp. 2244-2250
    • Poulin, M.J.1    Robbins, P.A.2
  • 32
    • 0029737496 scopus 로고    scopus 로고
    • Dynamics of the cerebral blood flow response to step changes in end-tidal pCO2 and pO2 in humans
    • Poulin M.J., Liang P.J., Robbins P.A. Dynamics of the cerebral blood flow response to step changes in end-tidal pCO2 and pO2 in humans. J Appl Physiol. 81:1996;1084-1095.
    • (1996) J Appl Physiol , vol.81 , pp. 1084-1095
    • Poulin, M.J.1    Liang, P.J.2    Robbins, P.A.3
  • 33
    • 0032924378 scopus 로고    scopus 로고
    • Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment
    • Ramnarine K.V., Hoskins P.R., Routh H.F., Davidson F. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment. Ultrasound Med Biol. 25:1999;105-110.
    • (1999) Ultrasound Med Biol , vol.25 , pp. 105-110
    • Ramnarine, K.V.1    Hoskins, P.R.2    Routh, H.F.3    Davidson, F.4
  • 34
    • 0032033499 scopus 로고    scopus 로고
    • Validation of a new blood-mimicking fluid for use in Doppler flow test objects
    • Ramnarine K.V., Nassiri D.K., Hoskins P.R., Lubbers J. Validation of a new blood-mimicking fluid for use in Doppler flow test objects. Ultrasound Med Biol. 24:1998;451-459.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 451-459
    • Ramnarine, K.V.1    Nassiri, D.K.2    Hoskins, P.R.3    Lubbers, J.4
  • 36
    • 0018941710 scopus 로고
    • Prediction of hemispheric blood flow from carotid velocity measurements: A study with the Doppler and Xe-133 techniques
    • Risberg J., Smith P. Prediction of hemispheric blood flow from carotid velocity measurements A study with the Doppler and Xe-133 techniques . Stroke. 11:1980;399-402.
    • (1980) Stroke , vol.11 , pp. 399-402
    • Risberg, J.1    Smith, P.2
  • 37
    • 0021972255 scopus 로고
    • Comparison of anterior cerebral artery blood flow velocity and cerebral blood flow during hypoxia
    • Rosenberg A.A., Narayanan V., Jones M.D. Comparison of anterior cerebral artery blood flow velocity and cerebral blood flow during hypoxia. Pediatr Res. 19:1985;67-70.
    • (1985) Pediatr Res , vol.19 , pp. 67-70
    • Rosenberg, A.A.1    Narayanan, V.2    Jones, M.D.3
  • 39
    • 0021044958 scopus 로고
    • Computerized evaluation of blood flow measurement indices using Doppler ultrasound
    • Saini V.D., Maulik D., Nanda N.C., Rosenzweig M.S. Computerized evaluation of blood flow measurement indices using Doppler ultrasound. Ultrasound Med Biol. 9:1983;657-660.
    • (1983) Ultrasound Med Biol , vol.9 , pp. 657-660
    • Saini, V.D.1    Maulik, D.2    Nanda, N.C.3    Rosenzweig, M.S.4
  • 40
    • 0028064394 scopus 로고
    • Transcranial Doppler sonography during isoflurane/N2) anaesthesia and surgery: Flow velocity, "vessel area" and "volume flow."
    • Schregel W., Schaefermeyer H., Sihle-Wissel M., Klein R. Transcranial Doppler sonography during isoflurane/N2) anaesthesia and surgery flow velocity, "vessel area" and "volume flow." Can J Anaesth. 41:1994;607-612.
    • (1994) Can J Anaesth , vol.41 , pp. 607-612
    • Schregel, W.1    Schaefermeyer, H.2    Sihle-Wissel, M.3    Klein, R.4
  • 41
    • 0021419743 scopus 로고
    • Effect of flow disturbance on ultrasonic backscatter from blood
    • Shung K.K., Yuan Y.W., Fei D.Y. Effect of flow disturbance on ultrasonic backscatter from blood. J Acoust Soc Am. 75:1984;1265-1272.
    • (1984) J Acoust Soc Am , vol.75 , pp. 1265-1272
    • Shung, K.K.1    Yuan, Y.W.2    Fei, D.Y.3
  • 42
    • 0023713616 scopus 로고
    • Intracranial arterial blood flow velocity and brain blood flow during hypocarbia and hypercarbia in newborn lambs: A validation of range gated Doppler ultrasound flow velocimetry
    • Sonesson S.E., Herin P. Intracranial arterial blood flow velocity and brain blood flow during hypocarbia and hypercarbia in newborn lambs a validation of range gated Doppler ultrasound flow velocimetry . Pediatr Res. 24:1988;423-426.
    • (1988) Pediatr Res , vol.24 , pp. 423-426
    • Sonesson, S.E.1    Herin, P.2
  • 44
    • 0025271202 scopus 로고
    • Doppler ultrasound spectral power density distribution: Measurement artefacts in steady flow
    • Thompson R.S., Aldis G.K., Linnett I.W. Doppler ultrasound spectral power density distribution measurement artefacts in steady flow . Med Biol Eng Comput. 28:1990;60-66.
    • (1990) Med Biol Eng Comput , vol.28 , pp. 60-66
    • Thompson, R.S.1    Aldis, G.K.2    Linnett, I.W.3
  • 45
    • 0027385434 scopus 로고
    • A quantitative investigation of the variability of the major cerebral arterial diameters
    • van der Zwan A., Hillen B., Tulleken C.A.F., Dujovny M. A quantitative investigation of the variability of the major cerebral arterial diameters. Stroke. 24:1993;1951-1959.
    • (1993) Stroke , vol.24 , pp. 1951-1959
    • Van Der Zwan, A.1    Hillen, B.2    Tulleken, C.A.F.3    Dujovny, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.