메뉴 건너뛰기




Volumn 139, Issue 4, 2000, Pages 675-683

Detection of angiographically significant coronary artery disease with accelerated intermittent imaging after intravenous administration of ultrasound contrast material

Author keywords

[No Author keywords available]

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CONTRAST MEDIUM; DOBUTAMINE; FLUOROCARBON; FS 069;

EID: 0034079543     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-8703(00)90047-4     Document Type: Article
Times cited : (65)

References (16)
  • 1
    • 0030829961 scopus 로고    scopus 로고
    • Evaluation of exercise thallium scintigraphy versus exercise electrocardiography in predicting survival and outcomes and morbid cardiac events in patients with single-and double-vessel disease: Findings from the Angioplasty Compared to Medicine (ACME) study
    • 1. Parisi AF, Hartigan PM, Folland ED, for the ACME Investigators. Evaluation of exercise thallium scintigraphy versus exercise electrocardiography in predicting survival and outcomes and morbid cardiac events in patients with single-and double-vessel disease: findings from the Angioplasty Compared to Medicine (ACME) Study. J Am Coll Cardiol 1997;30:1256-63.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1256-1263
    • Parisi, A.F.1    Hartigan, P.M.2    Folland, E.D.3
  • 2
    • 0028882611 scopus 로고
    • Transient myocardial contrast following initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: Demonstration and potential mechanisms
    • 2. Porter TR, Xie F. Transient myocardial contrast following initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: demonstration and potential mechanisms. Circulation 1995;92:2391-5.
    • (1995) Circulation , vol.92 , pp. 2391-2395
    • Porter, T.R.1    Xie, F.2
  • 3
    • 0029927502 scopus 로고    scopus 로고
    • Improved myocardial contrast with second harmonic transient ultrasound contrast response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin
    • 3. Porter TR, Xie F, Kricsfeld D, Armbruster RW. Improved myocardial contrast with second harmonic transient ultrasound contrast response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin. J Am Coll Cardiol 1996; 27:1497-501.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1497-1501
    • Porter, T.R.1    Xie, F.2    Kricsfeld, D.3    Armbruster, R.W.4
  • 4
    • 0030889485 scopus 로고    scopus 로고
    • Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging
    • 4. Porter TR, Li S, Kricsfeld D, Armbruster RW. Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J Am Coll Cardiol 1997;29:791-9.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 791-799
    • Porter, T.R.1    Li, S.2    Kricsfeld, D.3    Armbruster, R.W.4
  • 6
    • 0032533434 scopus 로고    scopus 로고
    • The clinical implications of no reflow demonstrated with intravenous perfluorocarbon containing microbubbles following restoration of thrombolysis in myocardial infarction (TIMI) 3 flow in patients with acute myocardial infarction
    • 6. Porter TR, Li S, Oster R, Deligonul U. The clinical implications of no reflow demonstrated with intravenous perfluorocarbon containing microbubbles following restoration of thrombolysis in myocardial infarction (TIMI) 3 flow in patients with acute myocardial infarction. Am J Cardiol 1998;82:1173-7.
    • (1998) Am J Cardiol , vol.82 , pp. 1173-1177
    • Porter, T.R.1    Li, S.2    Oster, R.3    Deligonul, U.4
  • 7
    • 0000073507 scopus 로고    scopus 로고
    • Simultaneous assessment of wall motion and myocardial perfusion using a rapid acquisition intermittent harmonic imaging pulsing interval of 5-15 Hz following acute myocardial infarction and during stress echocardiography
    • 7. Porter T, Li S, Oster R, Deligonul U. Simultaneous assessment of wall motion and myocardial perfusion using a rapid acquisition intermittent harmonic imaging pulsing interval of 5-15 Hz following acute myocardial infarction and during stress echocardiography (abstract). J Am Coll Cardiol 1998;31:123A.
    • (1998) J Am Coll Cardiol , vol.31
    • Porter, T.1    Li, S.2    Oster, R.3    Deligonul, U.4
  • 8
    • 0033009439 scopus 로고    scopus 로고
    • Real time visualization of myocardial perfusion and wall thickening in humans with intravenous ultrasound contrast and accelerated intermittent harmonic imaging
    • 8. Porter TR, Li S, Jiang L, Grayburn P, Deligonul U. Real time visualization of myocardial perfusion and wall thickening in humans with intravenous ultrasound contrast and accelerated intermittent harmonic imaging. J Am Soc Echocardiogr 1999;12:266-71.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 266-271
    • Porter, T.R.1    Li, S.2    Jiang, L.3    Grayburn, P.4    Deligonul, U.5
  • 9
    • 0027449411 scopus 로고
    • Accuracy of electronic digital calipers compared with quantitative angiography in measuring coronary arterial diameter
    • 9. Uehata A, Matsuguchi T, Bittl JA, et al. Accuracy of electronic digital calipers compared with quantitative angiography in measuring coronary arterial diameter. Circulation 1993;88:1724-9.
    • (1993) Circulation , vol.88 , pp. 1724-1729
    • Uehata, A.1    Matsuguchi, T.2    Bittl, J.A.3
  • 10
    • 0031182603 scopus 로고    scopus 로고
    • The effect of ultrasound frame rate on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and concentration when insonifying at different flow rates, transducer frequencies, and acoustic outputs
    • 10. Porter TR, Kricsfeld D, Cheatham S, Li S. The effect of ultrasound frame rate on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and concentration when insonifying at different flow rates, transducer frequencies, and acoustic outputs. J Am Soc Echocardiogr 1997;10:593-601.
    • (1997) J Am Soc Echocardiogr , vol.10 , pp. 593-601
    • Porter, T.R.1    Kricsfeld, D.2    Cheatham, S.3    Li, S.4
  • 11
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • 11. Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998;97:473-83.
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 12
    • 0030059734 scopus 로고    scopus 로고
    • Dobutamine-induced hypoperfusion without transient wall motion abnormalities: Less severe ischemia or less severe stress?
    • 12. Elhendy A, Geleijnse ML, Roelandt JRTC, et al. Dobutamine-induced hypoperfusion without transient wall motion abnormalities: less severe ischemia or less severe stress? J Am Coll Cardiol 1996; 27:323-9.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 323-329
    • Elhendy, A.1    Geleijnse, M.L.2    Roelandt, J.R.T.C.3
  • 13
    • 0031906143 scopus 로고    scopus 로고
    • Head-to-head comparison of exercise stress testing, pharmacologic stress echocardiography, and perfusion tomography as first-line examination for chest pain in patients without history of coronary artery disease
    • 13. Santoro GM, Sciagra R, Buonamici P, et al. Head-to-head comparison of exercise stress testing, pharmacologic stress echocardiography, and perfusion tomography as first-line examination for chest pain in patients without history of coronary artery disease. J Nucl Cardiol 1998;5:19-27.
    • (1998) J Nucl Cardiol , vol.5 , pp. 19-27
    • Santoro, G.M.1    Sciagra, R.2    Buonamici, P.3
  • 14
    • 0021971518 scopus 로고
    • Sequence of mechanical, electrocardiographic, and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty
    • 14. Hauser AM, Gangadharan V, Ramos RG, Gordon S, Timmis GC. Sequence of mechanical, electrocardiographic, and clinical effects of repeated coronary artery occlusion in human beings: echocardiographic observations during coronary angioplasty. J Am Coll Cardiol 1985;5:193-7.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 193-197
    • Hauser, A.M.1    Gangadharan, V.2    Ramos, R.G.3    Gordon, S.4    Timmis, G.C.5
  • 15
    • 0013687766 scopus 로고    scopus 로고
    • Disparate effects of dobutamine and dipyridamole on myocardial blood volume: Impications for stenosis detection by myocardial contrast echocardiography
    • 15. Bin J, Wei K, Pelberg RA, Goodman C, Kaul S. Disparate effects of dobutamine and dipyridamole on myocardial blood volume: impications for stenosis detection by myocardial contrast echocardiography (abstract). Circulation 1998;98:1-291.
    • (1998) Circulation , vol.98 , pp. 1-291
    • Bin, J.1    Wei, K.2    Pelberg, R.A.3    Goodman, C.4    Kaul, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.