-
1
-
-
0000700939
-
A simplified explanation of the theory of indicator-dilution for measurement of fluid flow and volume and other distributive phenomena
-
1 Zierler KR. A simplified explanation of the theory of indicator-dilution for measurement of fluid flow and volume and other distributive phenomena. Bull Johns Hopkins Hosp 1958; 103:199-223.
-
(1958)
Bull Johns Hopkins Hosp
, vol.103
, pp. 199-223
-
-
Zierler, K.R.1
-
2
-
-
0021084091
-
Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors
-
2 Mullani NA, Goldstein RA, Gould KL, Marini SK, Fisher DJ, O'Brien HA, Lobeng MD. Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors. J Nucl Med 1983; 24:898-906.
-
(1983)
J Nucl Med
, vol.24
, pp. 898-906
-
-
Mullani, N.A.1
Goldstein, R.A.2
Gould, K.L.3
Marini, S.K.4
Fisher, D.J.5
O'Brien, H.A.6
Lobeng, M.D.7
-
3
-
-
77049181625
-
On the theory of indicator-dilution method for measurement of blood flow and volume
-
3 Meier P, Zierler KL. On the theory of indicator-dilution method for measurement of blood flow and volume. J Appl Physiol 1954; 6:731-740.
-
(1954)
J Appl Physiol
, vol.6
, pp. 731-740
-
-
Meier, P.1
Zierler, K.L.2
-
5
-
-
0027770955
-
Myocardial regional blood flow: Quantitative measurement by computer analysis of contrast enhanced echocardiographic images
-
5 Mor-Avi V, David D, Akselrod S, Bitton Y, Choshniak I. Myocardial regional blood flow: quantitative measurement by computer analysis of contrast enhanced echocardiographic images. Ultrasound Med Biol 1993; 19:619-633.
-
(1993)
Ultrasound Med Biol
, vol.19
, pp. 619-633
-
-
Mor-Avi, V.1
David, D.2
Akselrod, S.3
Bitton, Y.4
Choshniak, I.5
-
7
-
-
0027219664
-
Volumetric arterial flow quantification using echo contrast. An in vitro comparison of three ultrasonic intensity methods: Radio frequency, video and Doppler
-
7 Schwarz KQ, Bezante GP, Chen X, Mottley JG, Schlief R. Volumetric arterial flow quantification using echo contrast. An in vitro comparison of three ultrasonic intensity methods: radio frequency, video and Doppler. Ultrasound Med Biol 1993; 19:447-460.
-
(1993)
Ultrasound Med Biol
, vol.19
, pp. 447-460
-
-
Schwarz, K.Q.1
Bezante, G.P.2
Chen, X.3
Mottley, J.G.4
Schlief, R.5
-
8
-
-
0027730388
-
Myocardial transit time of the echocardiographic contrast media
-
8 Mor-Avi V, Akselrod S, David D, Keselbrener L, Bitton Y. Myocardial transit time of the echocardiographic contrast media. Ultrasound Med Biol 1993; 19:635-648.
-
(1993)
Ultrasound Med Biol
, vol.19
, pp. 635-648
-
-
Mor-Avi, V.1
Akselrod, S.2
David, D.3
Keselbrener, L.4
Bitton, Y.5
-
9
-
-
0028308410
-
In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells
-
9 Jayaweera AR, Edwards N, Glasheen WP, Villanueva FS, Abbott RD, Kaul S. In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells. Circ Res 1994; 74:1157-1165. Demonstrates that the rheology of albumin microspheres is indistinguishable from red cells, supporting their use in the assessment of myocardial perfusion.
-
(1994)
Circ Res
, vol.74
, pp. 1157-1165
-
-
Jayaweera, A.R.1
Edwards, N.2
Glasheen, W.P.3
Villanueva, F.S.4
Abbott, R.D.5
Kaul, S.6
-
10
-
-
0030639184
-
Contrast echocardiography: Influence of ultrasonic machine settings, mixing conditions, and pressurization on pixel intensity and microsphere size of Albunex solutions in vitro
-
10 Ota T, Hillman ND, Craig D, Kisslo J, Smith PK. Contrast echocardiography: influence of ultrasonic machine settings, mixing conditions, and pressurization on pixel intensity and microsphere size of Albunex solutions in vitro. J Am Soc Echocardiogr 1997; 10:31-40.
-
(1997)
J Am Soc Echocardiogr
, vol.10
, pp. 31-40
-
-
Ota, T.1
Hillman, N.D.2
Craig, D.3
Kisslo, J.4
Smith, P.K.5
-
11
-
-
0030183871
-
Reduction in left ventricular cavitary attenuation and improvement in posterior myocardial contrast with higher molecular weight intravenous perfluorocarbon-exposed sonicated dextrose albumin microbubbles
-
11 Porter TR, Xie F, Kricsfeld A, Deligonul U, Kilzer K. Reduction in left ventricular cavitary attenuation and improvement in posterior myocardial contrast with higher molecular weight intravenous perfluorocarbon-exposed sonicated dextrose albumin microbubbles. J Am Soc Echocardiogr 1996; 9:437-441. Demonstration that bubbles with encapsulated gas of higher molecular weight and lower diffusivity than air are more stable with superior imaging characteristics.
-
(1996)
J Am Soc Echocardiogr
, vol.9
, pp. 437-441
-
-
Porter, T.R.1
Xie, F.2
Kricsfeld, A.3
Deligonul, U.4
Kilzer, K.5
-
12
-
-
8944227505
-
Loss of contrast intensity during systole in the left ventricular cavity with the use of the contrast agent Albunex. An analysis of its correlation with pressure and velocity
-
12 Tiukinhoy S, Bhoopalam S, Winkelmann JW, Ammar K, Mangulabran L, Reddy G, et al. Loss of contrast intensity during systole in the left ventricular cavity with the use of the contrast agent Albunex. An analysis of its correlation with pressure and velocity. Invest Radiol 1996; 31:415-422.
-
(1996)
Invest Radiol
, vol.31
, pp. 415-422
-
-
Tiukinhoy, S.1
Bhoopalam, S.2
Winkelmann, J.W.3
Ammar, K.4
Mangulabran, L.5
Reddy, G.6
-
13
-
-
0026830293
-
Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measurements
-
13 de Jong N, Hoff L, Skotland T, Bom N. Absorption and scatter of encapsulated gas filled microspheres: theoretical considerations and some measurements. Ultrasonics 1992; 30:95-103.
-
(1992)
Ultrasonics
, vol.30
, pp. 95-103
-
-
De Jong, N.1
Hoff, L.2
Skotland, T.3
Bom, N.4
-
17
-
-
0030997949
-
Interactions between microbubbles and ultrasound: In vitro and in vivo observations
-
17 Wei K, Skyba DM, Firschke C, Jayaweera AR, Lindner JR, Kaul S. Interactions between microbubbles and ultrasound: in vitro and in vivo observations. J Am Coll Cardiol 1997; 29:1081-1088.
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 1081-1088
-
-
Wei, K.1
Skyba, D.M.2
Firschke, C.3
Jayaweera, A.R.4
Lindner, J.R.5
Kaul, S.6
-
18
-
-
0028549958
-
Higher harmonics of vibrating gas-filled microspheres. Part one: Simulations
-
18 de Jong N, Cornet R, Lancee CT. Higher harmonics of vibrating gas-filled microspheres. Part one: simulations. Ultrasonics 1994; 32:447-453. Mathematical analysis and computer simulation demonstrating that when microbubbles are insonified below their resonant frequency, they emit energy at multiples of the insonifying energy.
-
(1994)
Ultrasonics
, vol.32
, pp. 447-453
-
-
De Jong, N.1
Cornet, R.2
Lancee, C.T.3
-
19
-
-
0014406592
-
Ultrasonic monitoring of decompression
-
19 Tucker DG, Welsby VG. Ultrasonic monitoring of decompression. Lancet 1968, i:1253.
-
(1968)
Lancet
, vol.1
, pp. 1253
-
-
Tucker, D.G.1
Welsby, V.G.2
-
20
-
-
0019612103
-
Ultrasonic detection of resonant cavitation bubbles in a flow tube by their second-harmonic emissions
-
20 Miller DL. Ultrasonic detection of resonant cavitation bubbles in a flow tube by their second-harmonic emissions. Ultrasonics 1981; 19:217-224.
-
(1981)
Ultrasonics
, vol.19
, pp. 217-224
-
-
Miller, D.L.1
-
21
-
-
0026191798
-
Principles and recent developments in ultrasound contrast agents
-
21 de Jong N, Ten Cate FJ, Lancee CT, Roelandt JR, Bom N. Principles and recent developments in ultrasound contrast agents. Ultrasonics 1991; 29:324-330.
-
(1991)
Ultrasonics
, vol.29
, pp. 324-330
-
-
De Jong, N.1
Ten Cate, F.J.2
Lancee, C.T.3
Roelandt, J.R.4
Bom, N.5
-
22
-
-
0016925396
-
Numerical investigation of nonlinear oscillations of gas bubbles in liquids
-
22 Lauterborn W. Numerical investigation of nonlinear oscillations of gas bubbles in liquids. J Acoust Soc Am 1976; 59:283-293.
-
(1976)
J Acoust Soc Am
, vol.59
, pp. 283-293
-
-
Lauterborn, W.1
-
23
-
-
0030059706
-
Harmonic imaging with ultrasound contrast agents
-
23 Burns PN. Harmonic imaging with ultrasound contrast agents. Clin Radiol 1996; 51:50-55.
-
(1996)
Clin Radiol
, vol.51
, pp. 50-55
-
-
Burns, P.N.1
-
24
-
-
0028550741
-
Higher harmonics of vibrating gas-filled microspheres. Part two: Measurements
-
24 de Jong N, Cornet R, Lancee CT. Higher harmonics of vibrating gas-filled microspheres. Part two: measurements. Ultrasonics 1994; 32:455-459. In vitro measurements confirming than when microbubbles are insonified below their resonant frequency, they emit energy at multiples of the insonifying frequency.
-
(1994)
Ultrasonics
, vol.32
, pp. 455-459
-
-
De Jong, N.1
Cornet, R.2
Lancee, C.T.3
-
25
-
-
0028882611
-
Transient myocardial contrast following initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: Demonstration and potential mechanisms
-
25 Porter TR, Xie F. Transient myocardial contrast following initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: demonstration and potential mechanisms. Circulation 1995; 92:2391-2395. Earty report of bubble destruction by ultrasound and perfusion assessment by triggered imaging.
-
(1995)
Circulation
, vol.92
, pp. 2391-2395
-
-
Porter, T.R.1
Xie, F.2
-
26
-
-
0030792911
-
Detection of coronary artery disease with myocardial contrast echocardiography: Comparison with 99mTc-sestamibi single-photon emission computed tomography
-
26 Kaul S, Senior R, Dittrich H, Rava U, Khattar R, Lahiri A. Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography. Circulation 1997; 96:785-792. Validation of ultrasonic imaging of perfluorocarbon filled microspheres in patients with chronic coronary artery disease.
-
(1997)
Circulation
, vol.96
, pp. 785-792
-
-
Kaul, S.1
Senior, R.2
Dittrich, H.3
Rava, U.4
Khattar, R.5
Lahiri, A.6
-
27
-
-
0030762422
-
Enhancement of left ventricular cavity opacification by harmonic imaging after venous injection of Albunex
-
27 Lindner JR, Dent JM, Moos SP, Jayaweera AR, Kaul S. Enhancement of left ventricular cavity opacification by harmonic imaging after venous injection of Albunex. Am J Cardiol 1997; 79:1657-1662.
-
(1997)
Am J Cardiol
, vol.79
, pp. 1657-1662
-
-
Lindner, J.R.1
Dent, J.M.2
Moos, S.P.3
Jayaweera, A.R.4
Kaul, S.5
-
28
-
-
0030778362
-
Effect of significant two-vessel versus one-vessel coronary artery stenosis on myocardial contrast defects observed with intermittent harmonic imaging after intravenous contrast injection during dobutamine stress echocardiography
-
28 Porter TR, Li S, Kilzer K, Deligonul U. Effect of significant two-vessel versus one-vessel coronary artery stenosis on myocardial contrast defects observed with intermittent harmonic imaging after intravenous contrast injection during dobutamine stress echocardiography. J Am Coll Cardiol 1997; 30:1399-1406.
-
(1997)
J Am Coll Cardiol
, vol.30
, pp. 1399-1406
-
-
Porter, T.R.1
Li, S.2
Kilzer, K.3
Deligonul, U.4
-
29
-
-
0030226472
-
Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging
-
29 Porter TR, Xie F, Shouping L, D'sa A, Rafter P. Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging. J Am Soc Echocardiogr 1996; 9:599-605. Validation of triggered imaging to enhance the strength of myocardial contrast.
-
(1996)
J Am Soc Echocardiogr
, vol.9
, pp. 599-605
-
-
Porter, T.R.1
Xie, F.2
Shouping, L.3
D'sa, A.4
Rafter, P.5
-
30
-
-
0030279882
-
Detection of myocardial perfusion abnormalities during dobutamine and adenosine stress echocardiography with transient myocardial contrast imaging after minute quantities of intravenous perfluorocarbon-exposed sonicated dextrose albumin
-
30 Porter TR, Xie F, Kilzer K, Deligonul U. Detection of myocardial perfusion abnormalities during dobutamine and adenosine stress echocardiography with transient myocardial contrast imaging after minute quantities of intravenous perfluorocarbon-exposed sonicated dextrose albumin. J Am Soc Echocardiogr 1996; 9:779-786.
-
(1996)
J Am Soc Echocardiogr
, vol.9
, pp. 779-786
-
-
Porter, T.R.1
Xie, F.2
Kilzer, K.3
Deligonul, U.4
-
31
-
-
0013650394
-
Detection of no-reflow zones using intravenous ultrasound contrast and intermittent harmonic imaging in patients with acute myocardial infarction and angiographically successful recanalization
-
31 Porter T, Li S, Deligonul U, Oster R. Detection of no-reflow zones using intravenous ultrasound contrast and intermittent harmonic imaging in patients with acute myocardial infarction and angiographically successful recanalization [abstract]. J Am Soc Echocardiogr 1997; 10:413.
-
(1997)
J Am Soc Echocardiogr
, vol.10
, pp. 413
-
-
Porter, T.1
Li, S.2
Deligonul, U.3
Oster, R.4
-
32
-
-
0031178076
-
Benefits of reducing the cardiac cycle-triggering frequency of ultrasound imaging to increase myocardial opacification with FSO69 during fundamental and second harmonic imaging
-
32 Colon PJ, Richards DR, Moreno CA, Murgo JP, Cheirif J. Benefits of reducing the cardiac cycle-triggering frequency of ultrasound imaging to increase myocardial opacification with FSO69 during fundamental and second harmonic imaging. J Am Soc Echocardiogr 1997; 10:602-607.
-
(1997)
J Am Soc Echocardiogr
, vol.10
, pp. 602-607
-
-
Colon, P.J.1
Richards, D.R.2
Moreno, C.A.3
Murgo, J.P.4
Cheirif, J.5
-
33
-
-
0030877547
-
Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent
-
33 Firschke C, Lindner JR, Wei K, Goodman NC, Skyba DM, Kaul S. Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent. Circulation 1997; 96:959-967.
-
(1997)
Circulation
, vol.96
, pp. 959-967
-
-
Firschke, C.1
Lindner, J.R.2
Wei, K.3
Goodman, N.C.4
Skyba, D.M.5
Kaul, S.6
-
34
-
-
0031023586
-
Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: Potential application in the cardiac catheterization laboratory
-
34 Firschke C, Lindner JR, Goodman NC, Skyba DM, Wei K, Kaul S. Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: potential application in the cardiac catheterization laboratory. J Am Coll Cardiol 1997; 29:207-216.
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 207-216
-
-
Firschke, C.1
Lindner, J.R.2
Goodman, N.C.3
Skyba, D.M.4
Wei, K.5
Kaul, S.6
-
35
-
-
0030889485
-
Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging
-
35 Porter TR, Li S, Kricsfeld D, Armbruster RW. Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J Am Coll Cardiol 1997; 29:791-799.
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 791-799
-
-
Porter, T.R.1
Li, S.2
Kricsfeld, D.3
Armbruster, R.W.4
-
36
-
-
0032501992
-
Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
-
36 Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998; 97:473-483. In vitro and animal validation of the concept of bubble destruction and fill-in as an approach to the quantification of myocardial blood flow. After destroying microbubbles within a slab of myocardium, intensity increases exponentially (proportional to blood velocity) to an asymptotic value (proportional to blood volume).
-
(1998)
Circulation
, vol.97
, pp. 473-483
-
-
Wei, K.1
Jayaweera, A.R.2
Firoozan, S.3
Linka, A.4
Skyba, D.M.5
Kaul, S.6
|