1
-
-
0028824489
-
Lake Louise consensus meeting on cyclosporin monitoring in organ transplantation: Report of the consensus panel
-
Oellerich M, Armstrong VW, Kahan B, et al. Lake Louise consensus meeting on cyclosporin monitoring in organ transplantation: Report of the consensus panel. Ther Drug Monit 1995;17(6): 642-54.
-
(1995)
Ther Drug Monit
, vol.17
, Issue.6
, pp. 642-654
-
-
Oellerich, M.1
Armstrong, V.W.2
Kahan, B.3
-
2
-
-
0025114353
-
Canadian consensus meeting on cyclosporine monitoring: Report of the consensus panel
-
Shaw LM, Yatscoff RW, Bowers LD, et al. Canadian consensus meeting on cyclosporine monitoring: report of the consensus panel. Clin Chem 1990;36(10):1841-6.
-
(1990)
Clin Chem
, vol.36
, Issue.10
, pp. 1841-1846
-
-
Shaw, L.M.1
Yatscoff, R.W.2
Bowers, L.D.3
-
3
-
-
0028980088
-
Optimizing the use of cyclosporine in renal transplantation
-
Sketris I, Yatscoff R, Keown P, et al. Optimizing the use of cyclosporine in renal transplantation. Clin Biochem 1995;28(3):195-211.
-
(1995)
Clin Biochem
, vol.28
, Issue.3
, pp. 195-211
-
-
Sketris, I.1
Yatscoff, R.2
Keown, P.3
-
4
-
-
0025148248
-
Consensus Document: Hawk's Cay meeting on therapeutic drug monitoring of cyclosporine
-
Kahan BD, Shaw LM, Holt D, Grevel J, Johnston A. Consensus Document: Hawk's Cay meeting on therapeutic drug monitoring of cyclosporine. Clin Chem 1990;36(8):1510-6.
-
(1990)
Clin Chem
, vol.36
, Issue.8
, pp. 1510-1516
-
-
Kahan, B.D.1
Shaw, L.M.2
Holt, D.3
Grevel, J.4
Johnston, A.5
-
5
-
-
0023232859
-
Critical issues in cyclosporin monitoring: Report of the task force on cyclosporin monitoring
-
Shaw LM, Bowers L, Demers L, et al. Critical issues in cyclosporin monitoring: Report of the task force on cyclosporin monitoring. Clin Chem 1987;33(7):1269-88.
-
(1987)
Clin Chem
, vol.33
, Issue.7
, pp. 1269-1288
-
-
Shaw, L.M.1
Bowers, L.2
Demers, L.3
-
6
-
-
0028019874
-
Cyclosporin-A monitoring in Australia: Consensus recommendations
-
Morris RG, Tett SE, Ray JE. Cyclosporin-A monitoring in Australia: Consensus recommendations. Ther Drug Monit 1994;16(6): 570-6.
-
(1994)
Ther Drug Monit
, vol.16
, Issue.6
, pp. 570-576
-
-
Morris, R.G.1
Tett, S.E.2
Ray, J.E.3
-
7
-
-
0028072644
-
Australian cyclosporin therapeutic monitoring survey - 1993
-
Morris RG. Australian cyclosporin therapeutic monitoring survey - 1993. Ther Drug Monit 1994;16(6):564-9.
-
(1994)
Ther Drug Monit
, vol.16
, Issue.6
, pp. 564-569
-
-
Morris, R.G.1
-
8
-
-
0031439489
-
Survey of cyclosporin therapeutic ranges, assay methodology and use of 'sparing agents' in Australasian transplant centres
-
Jones TE, Morris RG. Survey of cyclosporin therapeutic ranges, assay methodology and use of 'sparing agents' in Australasian transplant centres. Ther Drug Monit 1997;19:650-6.
-
(1997)
Ther Drug Monit
, vol.19
, pp. 650-656
-
-
Jones, T.E.1
Morris, R.G.2
-
9
-
-
0027226147
-
Influence of cyclosporine pharmacokinetics, trough concentrations, and AUC monitoring on outcome after kidney transplantation
-
Lindholm A, Kahan BD. Influence of cyclosporine pharmacokinetics, trough concentrations, and AUC monitoring on outcome after kidney transplantation. Clin Pharmacol Ther 1993;54:205-18.
-
(1993)
Clin Pharmacol Ther
, vol.54
, pp. 205-218
-
-
Lindholm, A.1
Kahan, B.D.2
-
10
-
-
0028846198
-
Challenges in cyclosporine therapy the role of therapeutic monitoring by area under the curve monitoring
-
Kahan BD, Welsh M, Rutzky LP. Challenges in cyclosporine therapy the role of therapeutic monitoring by area under the curve monitoring. Ther Drug Monit 1995;17(6):621-4.
-
(1995)
Ther Drug Monit
, vol.17
, Issue.6
, pp. 621-624
-
-
Kahan, B.D.1
Welsh, M.2
Rutzky, L.P.3
-
11
-
-
0024589575
-
Cyclosporin monitoring in renal transplantation: Area under the curve monitoring is superior to trough-level monitoring
-
Grevel J, Welsh MS, Kahan BD. Cyclosporin monitoring in renal transplantation: area under the curve monitoring is superior to trough-level monitoring. Ther Drug Monit 1989;11:252-66.
-
(1989)
Ther Drug Monit
, vol.11
, pp. 252-266
-
-
Grevel, J.1
Welsh, M.S.2
Kahan, B.D.3
-
12
-
-
0029808368
-
Abbreviated AUC strategy for monitoring cyclosporine microemulsion therapy in the immediate posttransplant period
-
Amante AJ, Kahan BD. Abbreviated AUC strategy for monitoring cyclosporine microemulsion therapy in the immediate posttransplant period. Transplant Proc 1996;28(4):2162-3.
-
(1996)
Transplant Proc
, vol.28
, Issue.4
, pp. 2162-2163
-
-
Amante, A.J.1
Kahan, B.D.2
-
13
-
-
0032985916
-
Abbreviated pharmacokinetic profiles in area-under-the-curve monitoring of cyclosporin therapy in de novo renal transplant patients treated with Sandimmune or Neoral
-
Marsh CL. Abbreviated pharmacokinetic profiles in area-under-the-curve monitoring of cyclosporin therapy in de novo renal transplant patients treated with Sandimmune or Neoral. Ther Drug Monit 1999;21:27-34.
-
(1999)
Ther Drug Monit
, vol.21
, pp. 27-34
-
-
Marsh, C.L.1
-
15
-
-
0031810775
-
Cyclosporine monitoring in patients with renal transplants: Two-or three-point methods that estimate area under the curve are superior to troughs in predicting drug exposure
-
Primmett DRN, Levine M, Kovarik JM, Mueller EA, Keown PA. Cyclosporine monitoring in patients with renal transplants: Two-or three-point methods that estimate area under the curve are superior to troughs in predicting drug exposure. Ther Drug Monit 1998;20:276-83.
-
(1998)
Ther Drug Monit
, vol.20
, pp. 276-283
-
-
Primmett, D.R.N.1
Levine, M.2
Kovarik, J.M.3
Mueller, E.A.4
Keown, P.A.5
-
16
-
-
0026700839
-
Comparison of cyclosporine measurement in whole blood by high performance liquid chromatography, monoclonal fluorescence polarisation immunoassay and monoclonal enzyme multiplied immunoassay
-
Dusci LJ, Hackett LP, Chiswell GM, Ilett KF. Comparison of cyclosporine measurement in whole blood by high performance liquid chromatography, monoclonal fluorescence polarisation immunoassay and monoclonal enzyme multiplied immunoassay. Ther Drug Monit 1992;14:327-32.
-
(1992)
Ther Drug Monit
, vol.14
, pp. 327-332
-
-
Dusci, L.J.1
Hackett, L.P.2
Chiswell, G.M.3
Ilett, K.F.4
-
17
-
-
0032963830
-
Performance and specificity of monoclonal immunoassays for cyclosporin monitoring: How specific is specific?
-
Steimer W. Performance and specificity of monoclonal immunoassays for cyclosporin monitoring: How specific is specific? Clin Chem 1999;45(3):371-81.
-
(1999)
Clin Chem
, vol.45
, Issue.3
, pp. 371-381
-
-
Steimer, W.1
-
18
-
-
0001109435
-
Evaluation of the Abbottt TDx monoclonal cyclosporine a assay in pediatric cardiac transplant patients
-
Rogers LC, Smith PA. Evaluation of the Abbottt TDx monoclonal cyclosporine A assay in pediatric cardiac transplant patients. Clin Chem 1991;37(6):1014.
-
(1991)
Clin Chem
, vol.37
, Issue.6
, pp. 1014
-
-
Rogers, L.C.1
Smith, P.A.2
-
19
-
-
0026653919
-
Specific EMIT and FPIA assays for cyclosporin compared with Cyclostrac 125I-RIA
-
Morris RG, Saccoia NC, Ryall RG, Peacock MK, Sallustio BC. Specific EMIT and FPIA assays for cyclosporin compared with Cyclostrac 125I-RIA. Ther Drug Monit 1992;14(3):226-33.
-
(1992)
Ther Drug Monit
, vol.14
, Issue.3
, pp. 226-233
-
-
Morris, R.G.1
Saccoia, N.C.2
Ryall, R.G.3
Peacock, M.K.4
Sallustio, B.C.5
-
20
-
-
0031712056
-
Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and EMIT); a critical overview of performance characteristics and comparision with HPLC
-
Schutz E, Svinarov D, Shipkova M, et al. Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and EMIT); a critical overview of performance characteristics and comparision with HPLC. Clin Chem 1998;44(10):2158-64.
-
(1998)
Clin Chem
, vol.44
, Issue.10
, pp. 2158-2164
-
-
Schutz, E.1
Svinarov, D.2
Shipkova, M.3
-
21
-
-
0032912183
-
Evaluatino of the new AxSYM cyclosporine assay: Comparison with TDx monoclonal whole blood and EMIT cyclosporine assays
-
Wallemacq PE, Alexandre K. Evaluatino of the new AxSYM cyclosporine assay: comparison with TDx monoclonal whole blood and EMIT cyclosporine assays. Clin Chem 1999;45(3):432-5.
-
(1999)
Clin Chem
, vol.45
, Issue.3
, pp. 432-435
-
-
Wallemacq, P.E.1
Alexandre, K.2
-
23
-
-
0025221317
-
Abbott TDx monoclonal assay evaluated for measuring cyclosporine in whole blood
-
Yatscoff RW, Copeland KR, Faraci CJ. Abbott TDx monoclonal assay evaluated for measuring cyclosporine in whole blood. Clin Chem 1990;36:1969-73.
-
(1990)
Clin Chem
, vol.36
, pp. 1969-1973
-
-
Yatscoff, R.W.1
Copeland, K.R.2
Faraci, C.J.3
|