메뉴 건너뛰기




Volumn 126, Issue 2-3, 2000, Pages 256-265

High-temperature corrosion of recuperators used in steel mills

Author keywords

Cr3C2 NiCr coating; Heat exchanger pipes; Molten salt corrosion; Recuperator; Thermal spray coatings

Indexed keywords

CERAMIC COATINGS; CERMETS; CORROSION RESISTANCE; HEAT EXCHANGERS; IRON AND STEEL PLANTS; MICROSTRUCTURE; MOLTEN MATERIALS; OXIDATION; RECUPERATORS; SALTS; SEAWATER CORROSION; SPRAYED COATINGS;

EID: 0034069933     PISSN: 02578972     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0257-8972(00)00523-5     Document Type: Article
Times cited : (37)

References (13)
  • 5
    • 0343224043 scopus 로고    scopus 로고
    • The Japanese Association of Thermal Spray, Ch. 8.3, Techno Consultants Inc., Tokyo
    • The Japanese Association of Thermal Spray, Handbook of Thermal Spray Technology, Ch. 8.3, Techno Consultants Inc., Tokyo, 1998.
    • (1998) Handbook of Thermal Spray Technology
  • 6
    • 0342789504 scopus 로고    scopus 로고
    • US Patent No. 4,725,512, Feb. 16, 1988
    • US Patent No. 4,725,512, Feb. 16, 1988.
  • 7
    • 0342789503 scopus 로고    scopus 로고
    • Tafa reference material 1.9.1.2-95MXC
    • Tafa reference material 1.9.1.2-95MXC.