메뉴 건너뛰기




Volumn 22, Issue 1, 2000, Pages 57-72

Calibrated parametric medical ultrasound imaging

Author keywords

Echography; Image processing; Parametric imaging; Texture; Ultrasound

Indexed keywords

DIAGNOSIS; IMAGE PROCESSING; IMAGE SEGMENTATION; PHANTOMS; TEXTURES; TISSUE; ULTRASONIC IMAGING; ULTRASONICS;

EID: 0034067753     PISSN: 01617346     EISSN: None     Source Type: Journal    
DOI: 10.1177/016173460002200104     Document Type: Article
Times cited : (51)

References (32)
  • 1
    • 0020955636 scopus 로고
    • A beam corrected estimation of the frequency dependent attenuation of biological tissues from backscattered ultrasound
    • Cloostermans, M.J.T.M. and Thijssen, J.M., A beam corrected estimation of the frequency dependent attenuation of biological tissues from backscattered ultrasound, Ultrasonic Imaging 5, 136-147 (1983).
    • (1983) Ultrasonic Imaging , vol.5 , pp. 136-147
    • Cloostermans, M.J.T.M.1    Thijssen, J.M.2
  • 2
    • 0021707678 scopus 로고
    • Beam pattern (diffraction) correction for ultrasonic attenuation measurements
    • Robinson, D.E., Wilson, L.S.and Bianchi, T., Beam pattern (diffraction) correction for ultrasonic attenuation measurements, Ultrasonic Imaging 6, 292-303 (1984).
    • (1984) Ultrasonic Imaging , vol.6 , pp. 292-303
    • Robinson, D.E.1    Wilson, L.S.2    Bianchi, T.3
  • 3
    • 0021466516 scopus 로고
    • Diffraction effects in pulse-echo measurement
    • Fink, M.A. and Cardoso, J.F., Diffraction effects in pulse-echo measurement, IEEE Trans. Sonics Ultras. SU-31, 313-329 (1984).
    • (1984) IEEE Trans. Sonics Ultras. , vol.SU-31 , pp. 313-329
    • Fink, M.A.1    Cardoso, J.F.2
  • 4
    • 0021286711 scopus 로고
    • Diffraction effects in reflected ultrasound spectral estimates
    • Kuc, R. and Regula, D.P., Diffraction effects in reflected ultrasound spectral estimates, IEEE Trans. Biomed. Eng. 31, 537-545 (1984).
    • (1984) IEEE Trans. Biomed. Eng. , vol.31 , pp. 537-545
    • Kuc, R.1    Regula, D.P.2
  • 5
    • 0022268239 scopus 로고
    • Diffraction and dispersion effects on the estimation of ultrasound attenuation and velocity in biological tissues
    • Verhoef, W.A., Cloostermans, M.J.T.M. and Thijssen, J.M., Diffraction and dispersion effects on the estimation of ultrasound attenuation and velocity in biological tissues, IEEE Trans. Biomed. Eng. 32, 521-529 (1985).
    • (1985) IEEE Trans. Biomed. Eng. , vol.32 , pp. 521-529
    • Verhoef, W.A.1    Cloostermans, M.J.T.M.2    Thijssen, J.M.3
  • 6
    • 0029760044 scopus 로고    scopus 로고
    • Precision and accuracy of acoustospectrographic parameters
    • Huisman, H.J. and Thijssen, J.M., Precision and accuracy of acoustospectrographic parameters, Ultrasound Med. Biol. 22, 855-871 (1996).
    • (1996) Ultrasound Med. Biol. , vol.22 , pp. 855-871
    • Huisman, H.J.1    Thijssen, J.M.2
  • 7
    • 0022364646 scopus 로고
    • Texture of B-mode echograms, 3-D simulations and experiments of the effects of diffraction and scatterer density
    • Oosterveld, B.J., Thijssen, J.M. and Verhoef, W.A., Texture of B-mode echograms, 3-D simulations and experiments of the effects of diffraction and scatterer density, Ultrasonic Imaging 7, 142-160 (1985).
    • (1985) Ultrasonic Imaging , vol.7 , pp. 142-160
    • Oosterveld, B.J.1    Thijssen, J.M.2    Verhoef, W.A.3
  • 8
    • 0023824534 scopus 로고
    • The correction of ultrasonic image analysis features for their depth dependence
    • Morris, D.T., The correction of ultrasonic image analysis features for their depth dependence, Int. J. Biomed. Comput. 22, 143-152 (1988).
    • (1988) Int. J. Biomed. Comput. , vol.22 , pp. 143-152
    • Morris, D.T.1
  • 10
    • 0024619430 scopus 로고
    • Local tissue attenuation images based on pulse-echo ultrasound scans
    • Walach, E., Shmulewitz, A., Itzchak, Y. and Heyman, Z., Local tissue attenuation images based on pulse-echo ultrasound scans, IEEE Trans. Biomed. Eng. 36, 211-221 (1989).
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 211-221
    • Walach, E.1    Shmulewitz, A.2    Itzchak, Y.3    Heyman, Z.4
  • 11
    • 0026870045 scopus 로고
    • Ultrasonic multifeature maps of 1 iver based on an amplitude loss technique and a conventional B-scan
    • Shmulewitz, A., Ultrasonic multifeature maps of 1 iver based on an amplitude loss technique and a conventional B-scan, IEEE Trans. Biomed. Eng. 39, 445-449 (1992).
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 445-449
    • Shmulewitz, A.1
  • 12
    • 0026777636 scopus 로고
    • Representation of texture parameters of B-mode scan sonograms in image form
    • Kodym, R. and Seyss, R., Representation of texture parameters of B-mode scan sonograms in image form, Ultraschall Med. 13, 116-118 (1992).
    • (1992) Ultraschall Med. , vol.13 , pp. 116-118
    • Kodym, R.1    Seyss, R.2
  • 14
    • 0025928357 scopus 로고
    • A method for characterizing soft tissue microstructure using parametric ultrasound imaging
    • Insana, M.F. and Hall, T.J., A method for characterizing soft tissue microstructure using parametric ultrasound imaging, Progr. Clin. Biol. Res. 363, 241-256 (1991).
    • (1991) Progr. Clin. Biol. Res. , vol.363 , pp. 241-256
    • Insana, M.F.1    Hall, T.J.2
  • 15
    • 0028730290 scopus 로고
    • Tissue characterizations of the prostate using kohonen maps
    • IEEE, New York, Cat. No. 94CH3468-6
    • Schmitz, G., Ermert, H. and Senge, T., Tissue characterizations of the prostate using Kohonen maps, in Proc IEEE Ultrason. Symp. pp. 1487-1490 (IEEE, New York, Cat. No. 94CH3468-6, 1994).
    • (1994) Proc IEEE Ultrason. Symp. , pp. 1487-1490
    • Schmitz, G.1    Ermert, H.2    Senge, T.3
  • 16
    • 0028196969 scopus 로고
    • Analysis of ultrasonographic prostate images for the detection of prostatic carcinoma: The automated urologic diagnostic expert system
    • Huynen, A.L., Giessen, R.J.B., de la Rosette, J.J.M.C.H., Aamink, R.G., Debruyne, F.M.J. and Wijkstra, H., Analysis of ultrasonographic prostate images for the detection of prostatic carcinoma: the automated urologic diagnostic expert system, Ultrasound Med. Biol. 20, 1-10 (1994).
    • (1994) Ultrasound Med. Biol. , vol.20 , pp. 1-10
    • Huynen, A.L.1    Giessen, R.J.B.2    De La Rosette, J.J.M.C.H.3    Aamink, R.G.4    Debruyne, F.M.J.5    Wijkstra, H.6
  • 17
    • 0028401526 scopus 로고
    • Image staining and differential diagnoses of ultrasound scans based on Mahalanobis distance
    • Momenan, R., Wagner, R.F., Garra, B.S., Loew, M.H. and Insana, M.F., Image staining and differential diagnoses of ultrasound scans based on Mahalanobis distance, IEEE Trans. Med. Imag. 13, 37-47 (1994).
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 37-47
    • Momenan, R.1    Wagner, R.F.2    Garra, B.S.3    Loew, M.H.4    Insana, M.F.5
  • 21
    • 0030971680 scopus 로고    scopus 로고
    • Characterization of echographic image texture by co-occurence parameters
    • Valckx, F.M.J. and Thijssen, J.M., Characterization of echographic image texture by co-occurence parameters, Ultrasound Med. Biol. 23, 559-571 (1997).
    • (1997) Ultrasound Med. Biol. , vol.23 , pp. 559-571
    • Valckx, F.M.J.1    Thijssen, J.M.2
  • 23
    • 0022358204 scopus 로고
    • Diagnostic accuracy of computerized B-scan texture analysis and conventional ultrasonography in diffuse parenchymal and malignant liver disease
    • Racth, U., Schlaps, D., Limberg, B., Zuna, I., Lorenz, A., van Kaick, G., Lorenz, W.J. and Kommerell, B., Diagnostic accuracy of computerized B-scan texture analysis and conventional ultrasonography in diffuse parenchymal and malignant liver disease. J. Clin. Ultrasound 13, 87-99 (1985).
    • (1985) J. Clin. Ultrasound , vol.13 , pp. 87-99
    • Racth, U.1    Schlaps, D.2    Limberg, B.3    Zuna, I.4    Lorenz, A.5    Van Kaick, G.6    Lorenz, W.J.7    Kommerell, B.8
  • 24
    • 0027219298 scopus 로고
    • Ultrasound image properties influenced by abdominal wall thickness and composition
    • Haberkorn, U., Layer, G., Rudat, V., Zuna, I., Lorenz, A. and van Kaick. G., Ultrasound image properties influenced by abdominal wall thickness and composition, J. Clin. Ultrasound 21, 423-429 (1993).
    • (1993) J. Clin. Ultrasound , vol.21 , pp. 423-429
    • Haberkorn, U.1    Layer, G.2    Rudat, V.3    Zuna, I.4    Lorenz, A.5    Van Kaick, G.6
  • 25
  • 26
    • 0025866714 scopus 로고
    • Ultrasound attenuation and texture analysis of diffuse liver disease: Methods and preliminary results
    • Oosterveld, B.J., Thijssen. J.M., Hartman, P.C., Romijn, R.L. and Rosenbusch, GJ.E., Ultrasound attenuation and texture analysis of diffuse liver disease: methods and preliminary results, Phys. Med. Biol. 36, 1039-1064 (1991).
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1039-1064
    • Oosterveld, B.J.1    Thijssen, J.M.2    Hartman, P.C.3    Romijn, R.L.4    Rosenbusch, G.J.E.5
  • 27
    • 0025957474 scopus 로고
    • Ultrasonic differentiation of intraocular melanomas: Parameters and estimation methods
    • Romijn, R.L., Thijssen, J.M., Oosterveld , B.J. and Verbeek, A.M., Ultrasonic differentiation of intraocular melanomas: parameters and estimation methods, Ultrasonic Imaging 13, 27-55 (1991).
    • (1991) Ultrasonic Imaging , vol.13 , pp. 27-55
    • Romijn, R.L.1    Thijssen, J.M.2    Oosterveld, B.J.3    Verbeek, A.M.4
  • 28
    • 0028539361 scopus 로고
    • US tissue characterization workstation: Applications and design
    • Krasner, B.H., Garra, B.S. and Mun, S.K., US tissue characterization workstation: applications and design. Radiographics 14, 1415-1422 (1994).
    • (1994) Radiographics , vol.14 , pp. 1415-1422
    • Krasner, B.H.1    Garra, B.S.2    Mun, S.K.3
  • 29
    • 0031876032 scopus 로고    scopus 로고
    • Adaptive texture feature extraction with application to echographic image analysis
    • Huisman, H.J., and Thijssen, J.M., Adaptive texture feature extraction with application to echographic image analysis, Ultrasonic Imaging 20, 132-148 (1998).
    • (1998) Ultrasonic Imaging , vol.20 , pp. 132-148
    • Huisman, H.J.1    Thijssen, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.