메뉴 건너뛰기




Volumn 11, Issue 3, 2000, Pages 333-336

Early failure of aortoiliac kissing stents: Histopathologic correlation

Author keywords

Aorta, stents and prostheses; Iliac arteries, stents and prostheses

Indexed keywords

ADULT; AORTA ATHEROSCLEROSIS; AORTA PROSTHESIS; ARTERY OCCLUSION; ARTERY PROSTHESIS; ARTICLE; CASE REPORT; FEMALE; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; ILIAC ARTERY; LERICHE SYNDROME; PRIORITY JOURNAL; STENT; TREATMENT FAILURE;

EID: 0034066091     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1051-0443(07)61426-2     Document Type: Article
Times cited : (32)

References (8)
  • 1
    • 0026201197 scopus 로고
    • Aortic bifurcation stenosis: Treatment with intravascular stents
    • Palmaz JC, Encarnacion CE, Garcia OJ, et al. Aortic bifurcation stenosis: treatment with intravascular stents. JVIR 1991; 2:319-323.
    • (1991) JVIR , vol.2 , pp. 319-323
    • Palmaz, J.C.1    Encarnacion, C.E.2    Garcia, O.J.3
  • 2
    • 0030068119 scopus 로고    scopus 로고
    • Aortic and iliac stenoses: Follow-up results of stent placement after insufficient balloon angioplasty in 118 cases
    • Vorwerk D, Gunther RW, Schurmann K. Aortic and iliac stenoses: follow-up results of stent placement after insufficient balloon angioplasty in 118 cases. Radiology 1996; 198:45-48.
    • (1996) Radiology , vol.198 , pp. 45-48
    • Vorwerk, D.1    Gunther, R.W.2    Schurmann, K.3
  • 3
    • 0031803158 scopus 로고    scopus 로고
    • Aortoiliac stent placement in patients treated for intermittent claudication
    • Murphy TP, Khwaja AA, Webb MS. Aortoiliac stent placement in patients treated for intermittent claudication. JVIR 1998; 9:421-428.
    • (1998) JVIR , vol.9 , pp. 421-428
    • Murphy, T.P.1    Khwaja, A.A.2    Webb, M.S.3
  • 5
    • 0025836204 scopus 로고
    • Percutaneous reconstruction of the aortic bifurcation with Palmaz stents: Case report
    • Kuffer G, Spengel F, Steckkmeier B. Percutaneous reconstruction of the aortic bifurcation with Palmaz stents: case report. Cardiovasc Intervent Radiol 1991; 14: 170-172.
    • (1991) Cardiovasc Intervent Radiol , vol.14 , pp. 170-172
    • Kuffer, G.1    Spengel, F.2    Steckkmeier, B.3
  • 6
    • 0002424216 scopus 로고    scopus 로고
    • Iliac artery stenting: A review of devices and technical considerations
    • Spinosa DJ, Angle JF, Hagspiel KD, et al. Iliac artery stenting: a review of devices and technical considerations. Appl Radiol Jul 1998; 10-24.
    • (1998) Appl Radiol Jul , pp. 10-24
    • Spinosa, D.J.1    Angle, J.F.2    Hagspiel, K.D.3
  • 7
    • 0344043454 scopus 로고    scopus 로고
    • Hemodynamics of endovascular prostheses
    • Fabregues S, Baijens K, Rieu R, et al. Hemodynamics of endovascular prostheses. J Biomech 1998; 31:45-54.
    • (1998) J Biomech , vol.31 , pp. 45-54
    • Fabregues, S.1    Baijens, K.2    Rieu, R.3
  • 8
    • 0032903720 scopus 로고    scopus 로고
    • Relationship between blood flow, thrombus, and neointima in stents
    • Richter GM, Palmaz JC, Noeldge G, et al. Relationship between blood flow, thrombus, and neointima in stents. JVIR 1999; 10:598-604.
    • (1999) JVIR , vol.10 , pp. 598-604
    • Richter, G.M.1    Palmaz, J.C.2    Noeldge, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.