메뉴 건너뛰기




Volumn 46, Issue 3, 2000, Pages 338-343

Development of an implantable small right ventricular assist device

Author keywords

[No Author keywords available]

Indexed keywords

BIOCOMPATIBILITY; BLOOD; CENTRIFUGAL PUMPS; IMPLANTS (SURGICAL);

EID: 0034066066     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-200005000-00019     Document Type: Article
Times cited : (6)

References (10)
  • 1
    • 0032899084 scopus 로고    scopus 로고
    • Mechanical circulatory support for one thousand days or more with the Novacor n100 left ventricular assist device
    • Dohmen PM, Laube H, de Jonge K, Baumann G, Konertz W: Mechanical circulatory support for one thousand days or more with the Novacor n100 left ventricular assist device. J Thorac Cardiovasc Surg 117: 1029-1030, 1999.
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 1029-1030
    • Dohmen, P.M.1    Laube, H.2    De Jonge, K.3    Baumann, G.4    Konertz, W.5
  • 3
    • 0030062849 scopus 로고    scopus 로고
    • Left ventricular contributions to right ventricular systolic function during LVAD support
    • Santamore WP, Gray LA: Left ventricular contributions to right ventricular systolic function during LVAD support. Ann Thorac Surg 61: 350-356, 1996.
    • (1996) Ann Thorac Surg , vol.61 , pp. 350-356
    • Santamore, W.P.1    Gray, L.A.2
  • 4
    • 18244416554 scopus 로고    scopus 로고
    • Preoperative and post-operative comparison of patients with univentricular and biventricular support with the Thoratec ventricular assist device as a bridge to cardiac transplantation
    • Farrar DJ, Hill JD, Pennington DG, et al: Preoperative and post-operative comparison of patients with univentricular and biventricular support with the Thoratec ventricular assist device as a bridge to cardiac transplantation. J Thorac Cardiovasc Surg 113: 202-209, 1997.
    • (1997) J Thorac Cardiovasc Surg , vol.113 , pp. 202-209
    • Farrar, D.J.1    Hill, J.D.2    Pennington, D.G.3
  • 5
    • 0000525256 scopus 로고
    • Characterization of protein coating for functional cardiac prosthesis
    • Kambic H, Murabayashi S, Harasaki H, Nosé Y: Characterization of protein coating for functional cardiac prosthesis. Artif Organs 5: 526, 1981.
    • (1981) Artif Organs , vol.5 , pp. 526
    • Kambic, H.1    Murabayashi, S.2    Harasaki, H.3    Nosé, Y.4
  • 7
    • 0032169982 scopus 로고    scopus 로고
    • Long-term in vivo left ventricular assist device study with a Titanium centrifugal Pump
    • Ohtsuka G, Nakata K, Yoshikawa M, et al: Long-term in vivo left ventricular assist device study with a Titanium centrifugal Pump. ASAIO J 44: M619-623, 1998.
    • (1998) ASAIO J , vol.44
    • Ohtsuka, G.1    Nakata, K.2    Yoshikawa, M.3
  • 8
    • 0031753806 scopus 로고    scopus 로고
    • Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump
    • Takami Y, Yamane S, Makinouchi K, Niimi Y, Sueoka A, Nosé Y: Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump. Artif Organs 22: 753-758, 1998.
    • (1998) Artif Organs , vol.22 , pp. 753-758
    • Takami, Y.1    Yamane, S.2    Makinouchi, K.3    Niimi, Y.4    Sueoka, A.5    Nosé, Y.6
  • 9
    • 0030040818 scopus 로고    scopus 로고
    • Experience with right ventricular assist devices for perioperative right-sided circulatory failure
    • Chen MJ, Levin HR, Rose EA, et al: Experience with right ventricular assist devices for perioperative right-sided circulatory failure. Ann Thorac Surg 61: 305-310, 1996.
    • (1996) Ann Thorac Surg , vol.61 , pp. 305-310
    • Chen, M.J.1    Levin, H.R.2    Rose, E.A.3
  • 10
    • 0030045151 scopus 로고    scopus 로고
    • Discussion of univentricular versus biventricular support
    • Hetzer R, Portner PM (moderators): Discussion of univentricular versus biventricular support. Ann Thorac Surg 61: 357-358, 1996.
    • (1996) Ann Thorac Surg , vol.61 , pp. 357-358
    • Hetzer, R.1    Portner, P.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.