-
1
-
-
0018526117
-
Biomechanics of the patellofemoral joint
-
Hungerford D.S., Barry M. Biomechanics of the patellofemoral joint. Clin Orthop. 144:1979;9-15.
-
(1979)
Clin Orthop
, vol.144
, pp. 9-15
-
-
Hungerford, D.S.1
Barry, M.2
-
2
-
-
0026628238
-
The effect of exercise on patellar tracking in lateral patellar compression syndrome
-
Doucette S.A., Goble E.M. The effect of exercise on patellar tracking in lateral patellar compression syndrome. Am J Sport Med. 20:1992;434-440.
-
(1992)
Am J Sport Med
, vol.20
, pp. 434-440
-
-
Doucette, S.A.1
Goble, E.M.2
-
3
-
-
0026675274
-
Quadriceps femoris muscle activity in patellofemoral pain syndrome
-
Boucher J.P., King M.A., Lefebvre R., Pepin A. Quadriceps femoris muscle activity in patellofemoral pain syndrome. Am J Sport Med. 20:1992;527-532.
-
(1992)
Am J Sport Med
, vol.20
, pp. 527-532
-
-
Boucher, J.P.1
King, M.A.2
Lefebvre, R.3
Pepin, A.4
-
4
-
-
0025853899
-
Comparison of vastus medialis obliques: Vastus lateralis muscle integrated electromyographic ratios between healthy subjects and patients with patellofemoral pain
-
Souza D., Gross M.T. Comparison of vastus medialis obliques: vastus lateralis muscle integrated electromyographic ratios between healthy subjects and patients with patellofemoral pain. Phys Ther. 71:1991;310-316.
-
(1991)
Phys Ther
, vol.71
, pp. 310-316
-
-
Souza, D.1
Gross, M.T.2
-
5
-
-
0025730130
-
Comparative reflex response times of vastus medialis obliquus and vastus lateralis in normal subjects and subjects with extensor mechanism dysfunction. An electromyographic study
-
Voight M.L., Wieder D.L. Comparative reflex response times of vastus medialis obliquus and vastus lateralis in normal subjects and subjects with extensor mechanism dysfunction. An electromyographic study. Am J Sport Med. 19:1991;131-137.
-
(1991)
Am J Sport Med
, vol.19
, pp. 131-137
-
-
Voight, M.L.1
Wieder, D.L.2
-
8
-
-
0023920571
-
Application of a magnetic tracking device to kinesiologic studies
-
An K.N., Jacobsen M.C., Berglund L.J., Chao E.Y.S. Application of a magnetic tracking device to kinesiologic studies. J Biomech. 21:1988;613-620.
-
(1988)
J Biomech
, vol.21
, pp. 613-620
-
-
An, K.N.1
Jacobsen, M.C.2
Berglund, L.J.3
Chao, E.Y.S.4
-
9
-
-
0025426762
-
The three-dimensional tracking pattern of the human patella
-
van Kampen A., Huiskes R. The three-dimensional tracking pattern of the human patella. J Orthop Res. 8:1990;372-382.
-
(1990)
J Orthop Res
, vol.8
, pp. 372-382
-
-
Van Kampen, A.1
Huiskes, R.2
-
10
-
-
0025696481
-
An anatomy-based coordinate system for the description of the kinematic displacements in the human knee
-
Pennock G.R., Clark K.J. An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. J Biomech. 23:1990;1209-1218.
-
(1990)
J Biomech
, vol.23
, pp. 1209-1218
-
-
Pennock, G.R.1
Clark, K.J.2
-
12
-
-
0016469431
-
Dysplasia of the quadriceps mechanism
-
Fox T.A. Dysplasia of the quadriceps mechanism. Surg Clin North Am. 55:1975;199-226.
-
(1975)
Surg Clin North Am
, vol.55
, pp. 199-226
-
-
Fox, T.A.1
-
13
-
-
0014377378
-
Quadriceps function. An anatomical and mechanical study using amputated limbs
-
Lieb F.J., Perry J. Quadriceps function. An anatomical and mechanical study using amputated limbs. J Bone J Surg A. 50:1968;1535-1548.
-
(1968)
J Bone J Surg a
, vol.50
, pp. 1535-1548
-
-
Lieb, F.J.1
Perry, J.2
-
15
-
-
0024503010
-
The anatomy of the extensor mechanism
-
Terry G.C. The anatomy of the extensor mechanism. Clin Sport Med. 8:1989;163-177.
-
(1989)
Clin Sport Med
, vol.8
, pp. 163-177
-
-
Terry, G.C.1
-
16
-
-
0027245906
-
Evaluation of the medial soft-tissue restraints of the extensor mechanism of the knee
-
Conlan T., Garth W.P., Lemons J.E. Evaluation of the medial soft-tissue restraints of the extensor mechanism of the knee. J Bone Joint Surg A. 75:1993;682-693.
-
(1993)
J Bone Joint Surg a
, vol.75
, pp. 682-693
-
-
Conlan, T.1
Garth, W.P.2
Lemons, J.E.3
|