메뉴 건너뛰기




Volumn 38, Issue 3, 2000, Pages 158-163

Systemic circulation and cerebral oxygenation during head-up tilt in spinal cord injured individuals

Author keywords

Near infrared spectroscopy; Portapres; Tetraplegia

Indexed keywords

ADULT; ARTICLE; BRAIN CIRCULATION; BRAIN OXYGEN TENSION; CLINICAL ARTICLE; CONTROLLED STUDY; HEAD POSITION; HEART OUTPUT; HEART RATE; HEART STROKE VOLUME; HOMEOSTASIS; HUMAN; MALE; MEAN ARTERIAL PRESSURE; NORMAL HUMAN; PRIORITY JOURNAL; SPINAL CORD INJURY; TILT TABLE TEST;

EID: 0034064843     PISSN: 13624393     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.sc.3100970     Document Type: Article
Times cited : (32)

References (26)
  • 1
    • 0021659775 scopus 로고
    • Cardiovascular and haemodynamic responses to tilling and to standing in tetraplegic patients: A review
    • 1 Figoni SF. Cardiovascular and haemodynamic responses to tilling and to standing in tetraplegic patients: a review. Paraplegia 1984; 22: 99-109.
    • (1984) Paraplegia , vol.22 , pp. 99-109
    • Figoni, S.F.1
  • 2
    • 0015070305 scopus 로고
    • Cardiovascular responses to tilt in tetraplegic man
    • 2 Corbett JL, Frankel HL, Harris PJ. Cardiovascular responses to tilt in tetraplegic man. J Physiol 1971; 215: 411-431.
    • (1971) J Physiol , vol.215 , pp. 411-431
    • Corbett, J.L.1    Frankel, H.L.2    Harris, P.J.3
  • 3
    • 0016834534 scopus 로고
    • Cardiovascular responses in tetraplegic man to muscle spasm, bladder percussion and head-up till
    • 3 Corbett JL, Debarge O, Frankel HL, Mathias CJ. Cardiovascular responses in tetraplegic man to muscle spasm, bladder percussion and head-up till. Clin Exp Pharm Physiol 1975; 2: (suppl) 189-193.
    • (1975) Clin Exp Pharm Physiol , vol.2 , Issue.SUPPL , pp. 189-193
    • Corbett, J.L.1    Debarge, O.2    Frankel, H.L.3    Mathias, C.J.4
  • 4
    • 0023866879 scopus 로고
    • Cardiovascular control in spinal man
    • 4 Mathias CJ. Cardiovascular control in spinal man. Ann Rev Physiol 1988; 50: 577-592.
    • (1988) Ann Rev Physiol , vol.50 , pp. 577-592
    • Mathias, C.J.1
  • 6
    • 84970060544 scopus 로고
    • Autoregulation of cerebral blood flow in patients with orthostatic hypotension after spinal cord injury
    • 6 Gonzalez F et al. Autoregulation of cerebral blood flow in patients with orthostatic hypotension after spinal cord injury. Paraplegia 1991; 29: 1-7.
    • (1991) Paraplegia , vol.29 , pp. 1-7
    • Gonzalez, F.1
  • 8
    • 0031020038 scopus 로고    scopus 로고
    • Cerebral and circulatory haemodynamics before vasovagal syncope induced by orthostatic stress
    • 8 Colier WNJM, Binkhorst RA, Hopman MTE, Oeseburg B. Cerebral and circulatory haemodynamics before vasovagal syncope induced by orthostatic stress. Clin Physiol 1997; 17: 83-94.
    • (1997) Clin Physiol , vol.17 , pp. 83-94
    • Colier, W.N.J.M.1    Binkhorst, R.A.2    Hopman, M.T.E.3    Oeseburg, B.4
  • 9
    • 75449129696 scopus 로고
    • Effect of tilting on the cardiovascular responses and plasma catecholamine levels in spinal man
    • 9 Guttman L et al. Effect of tilting on the cardiovascular responses and plasma catecholamine levels in spinal man. Paraplegia 1963; 1: 4-18.
    • (1963) Paraplegia , vol.1 , pp. 4-18
    • Guttman, L.1
  • 10
    • 0027470963 scopus 로고
    • Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording
    • 10 Imholz BPM et al. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording. Hypertension 1993; 21: 65-73.
    • (1993) Hypertension , vol.21 , pp. 65-73
    • Imholz, B.P.M.1
  • 11
    • 0029736631 scopus 로고    scopus 로고
    • Finger arterial versus intrahrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects
    • 11 Jellema WT et al. Finger arterial versus intrahrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects, Clin Sci 1996; 91: 193-200.
    • (1996) Clin Sci , vol.91 , pp. 193-200
    • Jellema, W.T.1
  • 12
    • 85047676115 scopus 로고
    • Non-invasive continuous flow blood pressure measurement during orthostatic stress compared to intra-arterial pressure
    • 12 Imholz PM et al. Non-invasive continuous flow blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovase Res 1990; 24: 214-221.
    • (1990) Cardiovase Res , vol.24 , pp. 214-221
    • Imholz, P.M.1
  • 13
    • 0028901025 scopus 로고
    • Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers
    • 13 Rongen GA et al. Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers. Am J Hypertens 1995; 8: 237-248.
    • (1995) Am J Hypertens , vol.8 , pp. 237-248
    • Rongen, G.A.1
  • 14
    • 0002765004 scopus 로고
    • A simple device for the continuous measurement of cardiac output. Its model basis and experimental verification
    • 14 Wesseling KH, de Wit B, Weher JAP, Smith NT. A simple device for the continuous measurement of cardiac output. Its model basis and experimental verification. Adv Cardiovasc Phys 1983; 5 (Suppl II): 16-52.
    • (1983) Adv Cardiovasc Phys , vol.5 , Issue.SUPPL. II , pp. 16-52
    • Wesseling, K.H.1    De Wit, B.2    Weher, J.A.P.3    Smith, N.T.4
  • 15
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • 15 Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 1993; 74: 2566-2573.
    • (1993) J Appl Physiol , vol.74 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.C.2    Settels, J.J.3    Schreuder, J.J.4
  • 16
    • 0013886708 scopus 로고
    • Strain-gauge plethysmography: Theoretical and practical notes on a new design
    • 16 Brakkee AJM, Vendrik AJH. Strain-gauge plethysmography: theoretical and practical notes on a new design. J Appl Physiol 1966; 21: 701-704.
    • (1966) J Appl Physiol , vol.21 , pp. 701-704
    • Brakkee, A.J.M.1    Vendrik, A.J.H.2
  • 17
    • 0026572727 scopus 로고
    • Ambulatory strain-gauge plethysmography and blood volume scintimetry for quantitative assessment of venous insufficiency
    • 17 Struckmann JR, Vissing SF, Hjortso E. Ambulatory strain-gauge plethysmography and blood volume scintimetry for quantitative assessment of venous insufficiency. Clin Physiol Oxf 1992; 12: 277-285.
    • (1992) Clin Physiol Oxf , vol.12 , pp. 277-285
    • Struckmann, J.R.1    Vissing, S.F.2    Hjortso, E.3
  • 18
    • 0028576954 scopus 로고
    • Properties of the venous vascular system in the lower extremities of individuals with paraplegia
    • 18 Hopman MTE et al. Properties of the venous vascular system in the lower extremities of individuals with paraplegia. Paraplegia 1994; 32: 810-816.
    • (1994) Paraplegia , vol.32 , pp. 810-816
    • Hopman, M.T.E.1
  • 20
    • 0030841745 scopus 로고    scopus 로고
    • Pathophysiological mechanisms underlying vasovagal syncope in young subjects
    • 20 Wieling W et al. Pathophysiological mechanisms underlying vasovagal syncope in young subjects. PACE 1997; 20 [Pt. II]: 2034-2038.
    • (1997) PACE , vol.20 , Issue.PT. II , pp. 2034-2038
    • Wieling, W.1
  • 21
    • 0030016244 scopus 로고    scopus 로고
    • Hemodynamic mechanism of vasovagal syncope
    • 21 Wang JJ et al. Hemodynamic mechanism of vasovagal syncope. Jpn Heart J 1996; 37: 361-371.
    • (1996) Jpn Heart J , vol.37 , pp. 361-371
    • Wang, J.J.1
  • 22
    • 0026283221 scopus 로고
    • Sympathetic reflex control of blood flow in human peripheral tissues
    • 22 Henriksen O. Sympathetic reflex control of blood flow in human peripheral tissues. Acta Physiol Scand Suppl 1991; 603: 33-39.
    • (1991) Acta Physiol Scand Suppl , vol.603 , pp. 33-39
    • Henriksen, O.1
  • 23
    • 0032984076 scopus 로고    scopus 로고
    • Reproducibility of the alterations in circulation and cerebral oxygenation from supine rest to head-up tilt
    • 23 Houtman S, Colier WNJM, Oesehurg B, Hopman MTE. Reproducibility of the alterations in circulation and cerebral oxygenation From supine rest to head-up tilt. Clin Physiol 1999; 19: 169-177.
    • (1999) Clin Physiol , vol.19 , pp. 169-177
    • Houtman, S.1    Colier, W.N.J.M.2    Oesehurg, B.3    Hopman, M.T.E.4
  • 24
    • 0028926692 scopus 로고
    • Regional cerebral blood flow, blood volume, oxygen extraction fraction, and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method
    • 24 Hawtazawa J et al. Regional cerebral blood flow, blood volume, oxygen extraction fraction, and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method. Ann Nucl Med 1995; 9: 15-21.
    • (1995) Ann Nucl Med , vol.9 , pp. 15-21
    • Hawtazawa, J.1
  • 25
    • 0028275683 scopus 로고
    • Cerebral versus systemic hemodynamics during graded orthostatic stress in humans
    • 25 Levine BD et al. Cerebral versus systemic hemodynamics during graded orthostatic stress in humans. Circulation 1993; 90: 298-306.
    • (1993) Circulation , vol.90 , pp. 298-306
    • Levine, B.D.1
  • 26
    • 0015541995 scopus 로고
    • Studies on cerebral circulation in man indicating presence of neurogenic control
    • 26 Corbett JL, Eidelman BH. Studies on cerebral circulation in man indicating presence of neurogenic control. Proc Aust Assoc Neurol 1973; 9: 133-144.
    • (1973) Proc Aust Assoc Neurol , vol.9 , pp. 133-144
    • Corbett, J.L.1    Eidelman, B.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.