메뉴 건너뛰기




Volumn 12, Issue 2, 2000, Pages 89-93

Uniport soft-tip, open-ended catheters versus multiport firm-tipped close-ended catheters for epidural labor analgesia: A quality assurance study

Author keywords

Analgesia; Anesthetic techniques; Epidural; Epidural catheters; Equipment and supplies; Obstetric

Indexed keywords

ADRENALIN; ANESTHETIC AGENT; BUPIVACAINE; FENTANYL; LIDOCAINE; ROPIVACAINE;

EID: 0034057530     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(00)00116-1     Document Type: Article
Times cited : (37)

References (16)
  • 1
    • 0030927310 scopus 로고    scopus 로고
    • A comparison of multiport and uniport epidural catheters in laboring patients
    • D'Angelo R., Foss M.L., Livesay C.H. A comparison of multiport and uniport epidural catheters in laboring patients. Anesth Analg. 84:1997;1276-1279.
    • (1997) Anesth Analg , vol.84 , pp. 1276-1279
    • D'Angelo, R.1    Foss, M.L.2    Livesay, C.H.3
  • 2
    • 0028034991 scopus 로고
    • Epidural catheters for obstetrics. Terminal hole or lateral eyes?
    • Collier C.B., Gatt S.P. Epidural catheters for obstetrics. Terminal hole or lateral eyes? Reg Anesth. 19:1994;378-385.
    • (1994) Reg Anesth , vol.19 , pp. 378-385
    • Collier, C.B.1    Gatt, S.P.2
  • 3
    • 0024317730 scopus 로고
    • A comparison between open-end (single hole) and closed-end (three lateral holes) epidural catheters. Complications and quality of sensory blockade
    • Michael S., Richmond M.N., Birks R.J. A comparison between open-end (single hole) and closed-end (three lateral holes) epidural catheters. Complications and quality of sensory blockade. Anaesthesia. 44:1989;578-580.
    • (1989) Anaesthesia , vol.44 , pp. 578-580
    • Michael, S.1    Richmond, M.N.2    Birks, R.J.3
  • 4
    • 0030961498 scopus 로고    scopus 로고
    • Superiority of multi-orifice over single-orifice epidural catheters for labor analgesia and cesarean delivery
    • Segal S., Eappen S., Datta S. Superiority of multi-orifice over single-orifice epidural catheters for labor analgesia and cesarean delivery. J Clin Anesth. 9:1997;109-112.
    • (1997) J Clin Anesth , vol.9 , pp. 109-112
    • Segal, S.1    Eappen, S.2    Datta, S.3
  • 5
    • 0025095368 scopus 로고
    • Comparison of complications associated with sinlgle-holed and multi-holed extradural catheters
    • Morrison L.M., Buchan A.S. Comparison of complications associated with sinlgle-holed and multi-holed extradural catheters. Br J Anaesth. 64:1990;183-185.
    • (1990) Br J Anaesth , vol.64 , pp. 183-185
    • Morrison, L.M.1    Buchan, A.S.2
  • 6
    • 0030773104 scopus 로고    scopus 로고
    • Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour
    • Dickson M.A., Moores C., McClure J.H. Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour. Br J Anaesth. 79:1997;297-300.
    • (1997) Br J Anaesth , vol.79 , pp. 297-300
    • Dickson, M.A.1    Moores, C.2    McClure, J.H.3
  • 7
    • 0031803272 scopus 로고    scopus 로고
    • Decreased incidence of complications in parturients with the arrow (FlexTip Plus) epidural catheter
    • Banwell B.R., Morley-Forster P., Krause R. Decreased incidence of complications in parturients with the arrow (FlexTip Plus) epidural catheter. Can J Anaesth. 45:1998;370-372.
    • (1998) Can J Anaesth , vol.45 , pp. 370-372
    • Banwell, B.R.1    Morley-Forster, P.2    Krause, R.3
  • 9
    • 0029757325 scopus 로고    scopus 로고
    • Lumbar epidurography with multi-orifice and single orifice epidural catheters
    • Magides A.D., Sprigg A., Richmond M.N. Lumbar epidurography with multi-orifice and single orifice epidural catheters. Anaesthesia. 51:1996;757-763.
    • (1996) Anaesthesia , vol.51 , pp. 757-763
    • Magides, A.D.1    Sprigg, A.2    Richmond, M.N.3
  • 10
    • 0023712830 scopus 로고
    • Differential flow from multihole epidural catheters
    • Power I., Thorburn J. Differential flow from multihole epidural catheters. Anaesthesia. 43:1988;876-878.
    • (1988) Anaesthesia , vol.43 , pp. 876-878
    • Power, I.1    Thorburn, J.2
  • 12
    • 0022613382 scopus 로고
    • Force exerted by epidural catheters
    • Hardy P.A. Force exerted by epidural catheters. Anaesthesia. 41:1986;306-308.
    • (1986) Anaesthesia , vol.41 , pp. 306-308
    • Hardy, P.A.1
  • 13
    • 0023004082 scopus 로고
    • Can epidural catheters penetrate dura mater? An anatomical study
    • Hardy P.A. Can epidural catheters penetrate dura mater? An anatomical study. Anaesthesia. 41:1986;1146-1147.
    • (1986) Anaesthesia , vol.41 , pp. 1146-1147
    • Hardy, P.A.1
  • 14
    • 0030049932 scopus 로고    scopus 로고
    • Dural puncture with Arrow Flex Tip Plus catheter
    • [Letter]
    • Cherala S.R. Dural puncture with Arrow Flex Tip Plus catheter. Reg Anesth. 21:1996;75-77. [Letter].
    • (1996) Reg Anesth , vol.21 , pp. 75-77
    • Cherala, S.R.1
  • 15
    • 0030752169 scopus 로고    scopus 로고
    • Delayed subarachnoid migration of an epidural Arrow FlexTip Plus catheter
    • [Letter]
    • Jaeger J.M., Madsen M.L. Delayed subarachnoid migration of an epidural Arrow FlexTip Plus catheter. Anesthesiology. 87:1997;718-719. [Letter].
    • (1997) Anesthesiology , vol.87 , pp. 718-719
    • Jaeger, J.M.1    Madsen, M.L.2
  • 16
    • 0023611727 scopus 로고
    • A comparison of two types of epidural catheters
    • Rolbin S.H., Hew E., Ogilvie G. A comparison of two types of epidural catheters. Can J Anaesth. 34:1987;459-461.
    • (1987) Can J Anaesth , vol.34 , pp. 459-461
    • Rolbin, S.H.1    Hew, E.2    Ogilvie, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.