메뉴 건너뛰기




Volumn 84, Issue 5, 2000, Pages 635-637

Carbon dioxide elimination during high-frequency jet ventilation for rigid bronchoscopy

Author keywords

Anaesthetic techniques, bronchoscopy; Monitoring, carbon dioxide; Ventilation, jet

Indexed keywords

CARBON DIOXIDE;

EID: 0034053848     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/84.5.635     Document Type: Article
Times cited : (24)

References (8)
  • 1
    • 0032897070 scopus 로고    scopus 로고
    • Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia
    • Rohling R, Biro P. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia. J Clin Monit 1999; 15:23-7
    • (1999) J Clin Monit , vol.15 , pp. 23-27
    • Rohling, R.1    Biro, P.2
  • 2
    • 0031596484 scopus 로고    scopus 로고
    • 2 elimination during high-frequency jet ventilation for laryngeal microsurgery
    • 2 elimination during high-frequency jet ventilation for laryngeal microsurgery. Anesth Analg 1998; 87: 180-4
    • (1998) Anesth Analg , vol.87 , pp. 180-184
    • Biro, P.1    Eyrich, G.2    Rohling, R.3
  • 4
    • 0031977954 scopus 로고    scopus 로고
    • Carbon dioxide and apnea: Common knowledge and common sense
    • Stock C. Carbon dioxide and apnea: common knowledge and common sense. J Clin Anesth 1998; 10: 181-3
    • (1998) J Clin Anesth , vol.10 , pp. 181-183
    • Stock, C.1
  • 5
    • 0030636840 scopus 로고    scopus 로고
    • Comparative study of high-frequency jet ventilation in 4 types of patients undergoing laryngeal microsurgery
    • Ayuso MA, Luis M, Sala X, Martinez G, Sanchez J, Alarcon A. Comparative study of high-frequency jet ventilation in 4 types of patients undergoing laryngeal microsurgery. Rev Esp Anestesiol Reanim 1997; 44: 7-12
    • (1997) Rev Esp Anestesiol Reanim , vol.44 , pp. 7-12
    • Ayuso, M.A.1    Luis, M.2    Sala, X.3    Martinez, G.4    Sanchez, J.5    Alarcon, A.6
  • 6
    • 0031594173 scopus 로고    scopus 로고
    • 2-elimination during combined high-frequency ventilation compared to conventional pressure-controlled ventilation in surfactant-deficient piglets
    • 2-elimination during combined high-frequency ventilation compared to conventional pressure-controlled ventilation in surfactant-deficient piglets. Acta Anaesthesiol Scand 1998; 42: 335-42
    • (1998) Acta Anaesthesiol Scand , vol.42 , pp. 335-342
    • Lichtwarck-Aschoff, M.1    Zimmermann, G.J.2    Erhardt, W.3
  • 8
    • 0025271151 scopus 로고
    • Carbon dioxide monitoring during high frequency jet ventilation for direct laryngosopy
    • Bourgain J-L, McGee K, Cosset MF, Bromley L, Meistelman C. Carbon dioxide monitoring during high frequency jet ventilation for direct laryngosopy. Br J Anaesth 1990; 64: 327-30
    • (1990) Br J Anaesth , vol.64 , pp. 327-330
    • Bourgain, J.-L.1    McGee, K.2    Cosset, M.F.3    Bromley, L.4    Meistelman, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.