메뉴 건너뛰기




Volumn 11, Issue 4, 2000, Pages 316-320

Temperature dependency of quantitative ultrasound

Author keywords

Osteoporosis; Quantitative ultrasound; Temperature

Indexed keywords

ARTICLE; CADAVER; CONTROLLED STUDY; CORRELATION FUNCTION; FOOT; HUMAN; HUMAN EXPERIMENT; HUMAN TISSUE; NORMAL HUMAN; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; TEMPERATURE DEPENDENCE; ULTRASOUND; WATER TEMPERATURE;

EID: 0034051338     PISSN: 0937941X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001980070120     Document Type: Article
Times cited : (19)

References (10)
  • 1
    • 0030737927 scopus 로고    scopus 로고
    • Quantitative ultrasound techniques for the assessment of osteoporosis: Expert agreement on current status
    • Glüer CC. Quantitative ultrasound techniques for the assessment of osteoporosis: expert agreement on current status. J Bone Miner Res 1997;8:1280-8.
    • (1997) J Bone Miner Res , vol.8 , pp. 1280-1288
    • Glüer, C.C.1
  • 2
    • 0026673516 scopus 로고
    • Site matched calcaneal measurements of broadband ultrasonic attenuation and single x-ray absorptiometry: Do they measure different skeletal properties?
    • Glüer CC, Vahlensieck M, Faulkner KG, et al. Site matched calcaneal measurements of broadband ultrasonic attenuation and single x-ray absorptiometry: Do they measure different skeletal properties? J Bone Miner Res 1992;7:1071-9.
    • (1992) J Bone Miner Res , vol.7 , pp. 1071-1079
    • Glüer, C.C.1    Vahlensieck, M.2    Faulkner, K.G.3
  • 3
    • 0030176206 scopus 로고    scopus 로고
    • Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation
    • Langton CM, Njeh CF, Hodgskinson R, Currey JD. Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation. Bone 1996;18:495-503.
    • (1996) Bone , vol.18 , pp. 495-503
    • Langton, C.M.1    Njeh, C.F.2    Hodgskinson, R.3    Currey, J.D.4
  • 4
    • 0030934837 scopus 로고    scopus 로고
    • Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women: A prospective study
    • Bauer DC, Glüer CC, Cauley JA, et al. Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women: a prospective study. Arch Intern Med 1997;157:629-34.
    • (1997) Arch Intern Med , vol.157 , pp. 629-634
    • Bauer, D.C.1    Glüer, C.C.2    Cauley, J.A.3
  • 5
    • 16044362010 scopus 로고    scopus 로고
    • Ultrasonographic heel measurements to predict hip fracture in elderly women: The EPIDOS study
    • Hans D, Dargent-Molina P, Schott AM, et al. Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS study. Lancet 1996;348:511-4.
    • (1996) Lancet , vol.348 , pp. 511-514
    • Hans, D.1    Dargent-Molina, P.2    Schott, A.M.3
  • 6
    • 0029986509 scopus 로고    scopus 로고
    • Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures
    • Marshall D, Johnell O, Wedel H. Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures. BMJ 1996;312:1254-9.
    • (1996) BMJ , vol.312 , pp. 1254-1259
    • Marshall, D.1    Johnell, O.2    Wedel, H.3
  • 7
    • 0030741645 scopus 로고    scopus 로고
    • Precision and discriminatory ability of calcaneal bone assessment technologies
    • Greenspan SL, Bouxsein ML, Melton ME, et al. Precision and discriminatory ability of calcaneal bone assessment technologies. J Bone Miner Res 1997;8:1303-13.
    • (1997) J Bone Miner Res , vol.8 , pp. 1303-1313
    • Greenspan, S.L.1    Bouxsein, M.L.2    Melton, M.E.3
  • 8
    • 0008168790 scopus 로고    scopus 로고
    • Stiffness compensates for temperature variation in ultrasound densitometry
    • Morris R, Mazess RB, Trempe J, Hanson JA. Stiffness compensates for temperature variation in ultrasound densitometry. J Bone Miner Res 1997;12(Suppl 1):S388.
    • (1997) J Bone Miner Res , vol.12 , Issue.SUPPL. 1
    • Morris, R.1    Mazess, R.B.2    Trempe, J.3    Hanson, J.A.4
  • 9
    • 0004702095 scopus 로고    scopus 로고
    • The influence of soft tissue and water bath temperature on quantitative ultrasound transmission parameters: An in-vivo study
    • Barkmann R, Heller M, Glüer CC. The influence of soft tissue and water bath temperature on quantitative ultrasound transmission parameters: an in-vivo study. Osteoporos Int 1996;6(Suppl 1):181.
    • (1996) Osteoporos Int , vol.6 , Issue.SUPPL. 1 , pp. 181
    • Barkmann, R.1    Heller, M.2    Glüer, C.C.3
  • 10
    • 0002470583 scopus 로고    scopus 로고
    • Factors influencing QUS parameters of the calcaneum: Suggestions for an improved measurement procedure
    • Barkmann R, Cluer C. Factors influencing QUS parameters of the calcaneum: suggestions for an improved measurement procedure. J Clin Densitom 1998;1:93-4.
    • (1998) J Clin Densitom , vol.1 , pp. 93-94
    • Barkmann, R.1    Cluer, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.