메뉴 건너뛰기




Volumn 114, Issue 2, 2000, Pages 125-127

Vagus nerve stimulation: Quality control in thyroid and parathyroid surgery

Author keywords

Monitoring; Operative; Parathyroid glands; Physiologic; Recurrent laryngeal nerve; Surgery; Thyroid gland

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; FEMALE; HEAD AND NECK SURGERY; HUMAN; MALE; MEDICAL INSTRUMENTATION; MONITORING; PARATHYROID GLAND; RECURRENT LARYNGEAL NERVE; SURGICAL TECHNIQUE; THYROID GLAND; THYROID SURGERY; VAGUS NERVE STIMULATION;

EID: 0034049856     PISSN: 00222151     EISSN: None     Source Type: Journal    
DOI: 10.1258/0022215001905067     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 79958786345 scopus 로고
    • Evolution of endocrine surgery
    • New York: Praeger
    • Welbourn RB. Evolution of endocrine surgery. In: History of Endocrine Surgery. New York: Praeger, 1990:21
    • (1990) History of Endocrine Surgery , pp. 21
    • Welbourn, R.B.1
  • 3
    • 0027512593 scopus 로고
    • Complications of the surgery of the thyroid and parathyroid glands
    • Kahky MP, Webber RS. Complications of the surgery of the thyroid and parathyroid glands. Surg Clin North Am 1993;72:307-21
    • (1993) Surg Clin North Am , vol.72 , pp. 307-321
    • Kahky, M.P.1    Webber, R.S.2
  • 4
    • 0038187017 scopus 로고
    • Exposure of the recurrent laryngeal nerves in thyroid operations
    • Lahey FH. Exposure of the recurrent laryngeal nerves in thyroid operations. Surg Gynecol Obstet 1944;78:293-4
    • (1944) Surg Gynecol Obstet , vol.78 , pp. 293-294
    • Lahey, F.H.1
  • 5
    • 0000842483 scopus 로고
    • Vulnerability of the recurrent laryngeal nerve at thyroidectomy
    • Wade JSH. Vulnerability of the recurrent laryngeal nerve at thyroidectomy. B J Surg 1955;43:164-80
    • (1955) B J Surg , vol.43 , pp. 164-180
    • Wade, J.S.H.1
  • 6
    • 49749193552 scopus 로고
    • Injury to the recurrent laryngeal nerve during thyroidectomy
    • Riddell VH. Injury to the recurrent laryngeal nerve during thyroidectomy. Lancet 1956;ii:638-41
    • (1956) Lancet , vol.2 , pp. 638-641
    • Riddell, V.H.1
  • 7
    • 0023601893 scopus 로고
    • Facial-nerve and vocal-cord monitoring during otoneurosurgical operations
    • Zini C, Gandolfi A. Facial-nerve and vocal-cord monitoring during otoneurosurgical operations. Arch Otolaryngol Head Neck Surg 1987;113:1291-3
    • (1987) Arch Otolaryngol Head Neck Surg , vol.113 , pp. 1291-1293
    • Zini, C.1    Gandolfi, A.2
  • 8
    • 0024244910 scopus 로고
    • Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve during thyroid surgery
    • Lipton RJ, McCaffry TV, Litchy WJ. Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve during thyroid surgery. Laryngoscope 1988;98:1292-6
    • (1988) Laryngoscope , vol.98 , pp. 1292-1296
    • Lipton, R.J.1    McCaffry, T.V.2    Litchy, W.J.3
  • 10
    • 0030116793 scopus 로고    scopus 로고
    • Intraoperatives monitoring des nervus laryngeus recurrens - Eine neue methode
    • Lamade W, Fogel W, Rieke K, Senniger N, Herfarth Ch. Intraoperatives monitoring des nervus laryngeus recurrens - eine neue methode. Chirurgie 1996;67:451-4
    • (1996) Chirurgie , vol.67 , pp. 451-454
    • Lamade, W.1    Fogel, W.2    Rieke, K.3    Senniger, N.4    Herfarth, Ch.5
  • 11
    • 0030959375 scopus 로고    scopus 로고
    • The NIM-2 nerve integrity monitor in thyroid and parathyroid surgery
    • Barwell J, Lytle J, Page R, Wilkins D. The NIM-2 nerve integrity monitor in thyroid and parathyroid surgery. Br J Surg 1997;84:854
    • (1997) Br J Surg , vol.84 , pp. 854
    • Barwell, J.1    Lytle, J.2    Page, R.3    Wilkins, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.