Volumn 35, Issue 4, 2000, Pages 219-226

Automated calibration in vascular x-ray images using the accurate localization of catheter marker bands

Author keywords

Calibration; Catheter markers; Center of gravity; Curve fitting; Hough transform; Stenosis quantification; Vascular angiography

Indexed keywords

ARTERIOGRAPHY; ARTICLE; AUTOMATION; BLOOD VESSEL CATHETERIZATION; BLOOD VESSEL DIAMETER; CALIBRATION; IMAGE ANALYSIS; PRIORITY JOURNAL; X RAY ANALYSIS;

EID: 0034046741     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-200004000-00002     Document Type: Article
Times cited : (6)

References (27)
  • 1
    • 0038064904 scopus 로고    scopus 로고
    • Current and future developments in QCA and image fusion with IVUS
    • Reiber JHC, van der Wall EE, eds. Dordrecht, Netherlands: Kluwer Academic Publishers
    • Reiber JHC, Dijkstra J, Koning G, Oemrawsingh PV, Schalij MJ, Goedhart B. Current and future developments in QCA and image fusion with IVUS. In: Reiber JHC, van der Wall EE, eds. What's new in cardiovascular imaging? Dordrecht, Netherlands: Kluwer Academic Publishers; 1998:17-29.
    • (1998) What's New in Cardiovascular Imaging? , pp. 17-29
    • Reiber, J.H.C.1    Dijkstra, J.2    Koning, G.3    Oemrawsingh, P.V.4    Schalij, M.J.5    Goedhart, B.6
  • 2
    • 0017348841 scopus 로고
    • Quantitative coronary arteriography: Estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation
    • Brown BG, Bolson E, Frimer M, Dodge HT. Quantitative coronary arteriography: Estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation. Circulation 1977;55:329-337.
    • (1977) Circulation , vol.55 , pp. 329-337
    • Brown, B.G.1    Bolson, E.2    Frimer, M.3    Dodge, H.T.4
  • 3
    • 0342875508 scopus 로고
    • Morphologic and densitometric quantitation of coronary stenoses; an overview of existing quantitation techniques
    • Reiber JHC, Serruys PW, eds. Dordrecht, Netherlands: Kluwer Academic Publishers
    • Reiber JHC. Morphologic and densitometric quantitation of coronary stenoses; an overview of existing quantitation techniques. In: Reiber JHC, Serruys PW, eds. New developments in quantitative coronary arteriography. Dordrecht, Netherlands: Kluwer Academic Publishers; 1988:33-88.
    • (1988) New Developments in Quantitative Coronary Arteriography , pp. 33-88
    • Reiber, J.H.C.1
  • 5
    • 0027243404 scopus 로고
    • Definition and measurement of restenosis after successful coronary angioplasty: Implication for clinical trials
    • Lespérance J, Bourassa MG, Schwartz L, et al. Definition and measurement of restenosis after successful coronary angioplasty: Implication for clinical trials. Am Heart J 1993;125:1394-1408.
    • (1993) Am Heart J , vol.125 , pp. 1394-1408
    • Lespérance, J.1    Bourassa, M.G.2    Schwartz, L.3
  • 6
    • 0002170785 scopus 로고    scopus 로고
    • Issues in the performance of quantitative coronary angiography in clinical research trials
    • Reiber JHC, van der Wall EE, eds. Dordrecht, Netherlands: Kluwer Academic Publishers
    • Lespérance J, Bilodeau L, Reiber JHC, Koning G, Hudon G, Bourassa MG. Issues in the performance of quantitative coronary angiography in clinical research trials. In: Reiber JHC, van der Wall EE, eds. What's new in cardiovascular imaging? Dordrecht, Netherlands: Kluwer Academic Publishers; 1998:31-46.
    • (1998) What's New in Cardiovascular Imaging? , pp. 31-46
    • Lespérance, J.1    Bilodeau, L.2    Reiber, J.H.C.3    Koning, G.4    Hudon, G.5    Bourassa, M.G.6
  • 7
    • 2442640193 scopus 로고    scopus 로고
    • The cost-effectiveness of QCA in interventional cardiology
    • Reiber JHC, van der Wall EE, eds. Dordrecht, Netherlands: Kluwer Academic Publishers
    • Nienaber CA, Schaps K-P, Stiel G. The cost-effectiveness of QCA in interventional cardiology. In: Reiber JHC, van der Wall EE, eds. What's new in cardiovascular imaging? Dordrecht, Netherlands: Kluwer Academic Publishers; 1998:47-60.
    • (1998) What's New in Cardiovascular Imaging? , pp. 47-60
    • Nienaber, C.A.1    Schaps, K.-P.2    Stiel, G.3
  • 8
    • 0027462837 scopus 로고
    • Accuracy and precision of quantitative digital coronary arteriography
    • Reiber JHC, van der Zwet PMJ, Koning G, et al. Accuracy and precision of quantitative digital coronary arteriography. Cathet Cardiovasc Diagn 1993;28:187-198.
    • (1993) Cathet Cardiovasc Diagn , vol.28 , pp. 187-198
    • Reiber, J.H.C.1    Van Der Zwet, P.M.J.2    Koning, G.3
  • 10
    • 0025111082 scopus 로고
    • Validation of a new automatic system for biplane quantitative coronary arteriography
    • Büchi M, Hess OM, Kirkeeide RL, et al. Validation of a new automatic system for biplane quantitative coronary arteriography. Int J Card Imaging 1990;5:93-103.
    • (1990) Int J Card Imaging , vol.5 , pp. 93-103
    • Büchi, M.1    Hess, O.M.2    Kirkeeide, R.L.3
  • 11
    • 0022192187 scopus 로고
    • Improvement of quantitative coronary angiography by calculation of exact magnification factors
    • Wollschläger H, Lee P, Zeiher AM, Solzbach U, Bonzel T, Just H. Improvement of quantitative coronary angiography by calculation of exact magnification factors. Comput Cardiol 1985;12: 483-486.
    • (1985) Comput Cardiol , vol.12 , pp. 483-486
    • Wollschläger, H.1    Lee, P.2    Zeiher, A.M.3    Solzbach, U.4    Bonzel, T.5    Just, H.6
  • 12
    • 0026001738 scopus 로고
    • Advantages and limitations of two software calipers in quantitative coronary arteriography
    • Koning G, Reiber JH, von Land CD, Loois G, van Meurs B. Advantages and limitations of two software calipers in quantitative coronary arteriography. Int J Card Imaging 1991;7:15-30.
    • (1991) Int J Card Imaging , vol.7 , pp. 15-30
    • Koning, G.1    Reiber, J.H.2    Von Land, C.D.3    Loois, G.4    Van Meurs, B.5
  • 13
    • 0026655142 scopus 로고
    • Angiographie assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriograms
    • Koning G, van der Zwet PMJ, von Land CD, Reiber JHC. Angiographie assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriograms. Int J Card Imaging 1992;8:153-161.
    • (1992) Int J Card Imaging , vol.8 , pp. 153-161
    • Koning, G.1    Van Der Zwet, P.M.J.2    Von Land, C.D.3    Reiber, J.H.C.4
  • 15
    • 0002975580 scopus 로고
    • Comparison of accuracy and precision of quantitative coronary arterial analysis between cinefilm and digital systems
    • Reiber JHC, Serruys PW, eds. Dordrecht, Netherlands: Kluwer Academic Publishers
    • Reiber JHC, von Land CD, Koning G, et al. Comparison of accuracy and precision of quantitative coronary arterial analysis between cinefilm and digital systems. In: Reiber JHC, Serruys PW, eds. Progress in quantitative coronary arteriography. Dordrecht, Netherlands: Kluwer Academic Publishers; 1994:67-85.
    • (1994) Progress in Quantitative Coronary Arteriography , pp. 67-85
    • Reiber, J.H.C.1    Von Land, C.D.2    Koning, G.3
  • 16
    • 12944302845 scopus 로고    scopus 로고
    • Suitability of the stabilizer marker wire for QCA calibration; in vitro study
    • Koning G, Kemppainen JS, Rothman MT, Reiber JHC. Suitability of the stabilizer marker wire for QCA calibration; in vitro study. Eur Heart J 1997;18:391.
    • (1997) Eur Heart J , vol.18 , pp. 391
    • Koning, G.1    Kemppainen, J.S.2    Rothman, M.T.3    Reiber, J.H.C.4
  • 17
    • 12944325552 scopus 로고    scopus 로고
    • A method and means for recognizing complex patterns. US patent application No. 3069654, 1962
    • Hough PVC. A method and means for recognizing complex patterns. US patent application No. 3069654, 1962.
    • Hough, P.V.C.1
  • 19
    • 0032634890 scopus 로고    scopus 로고
    • Recognition of radiopaque markers in x-ray images using a neural network as nonlinear filter
    • Egmont-Petersen M, Arts T. Recognition of radiopaque markers in x-ray images using a neural network as nonlinear filter. Pattern Recognit Lett 1999;20:521-533.
    • (1999) Pattern Recognit Lett , vol.20 , pp. 521-533
    • Egmont-Petersen, M.1    Arts, T.2
  • 24
    • 0029014292 scopus 로고
    • Automated and accurate assessment of the distribution, magnitude, and direction of pincushion distortion in angiographic images
    • van der Zwet PMJ, Meyer AJH, Reiber JHC. Automated and accurate assessment of the distribution, magnitude, and direction of pincushion distortion in angiographic images. Invest Radiol 1995;30:204-213.
    • (1995) Invest Radiol , vol.30 , pp. 204-213
    • Van Der Zwet, P.M.J.1    Meyer, A.J.H.2    Reiber, J.H.C.3
  • 25
    • 0033988978 scopus 로고    scopus 로고
    • Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries
    • Westenberg JJM, van der Geest RJ, Wasser MNJM, et al. Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries. Magn Reson Imaging 2000; 18:13-22.
    • (2000) Magn Reson Imaging , vol.18 , pp. 13-22
    • Westenberg, J.J.M.1    Van Der Geest, R.J.2    Wasser, M.N.J.M.3
  • 26
    • 0029327157 scopus 로고
    • Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms
    • Wahle A, Wellnhofer E, Mugaragu I, Sauer HU, Oswald H, Fleck E. Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms. IEEE Trans Med Imaging 1995;14: 230-241.
    • (1995) IEEE Trans Med Imaging , vol.14 , pp. 230-241
    • Wahle, A.1    Wellnhofer, E.2    Mugaragu, I.3    Sauer, H.U.4    Oswald, H.5    Fleck, E.6
  • 27
    • 2342630395 scopus 로고    scopus 로고
    • Präzise dreidimensionale Rekonstruktion von Gefäßsystemen aus biplanen angiographischen Projektionen und deren klinische Anwendung
    • Düsseldorf, Germany: VDI Verlag;
    • Wahle A. Präzise dreidimensionale Rekonstruktion von Gefäßsystemen aus biplanen angiographischen Projektionen und deren klinische Anwendung. Fortschritt-Berichte. Vol. 152. Düsseldorf, Germany: VDI Verlag; 1997.
    • (1997) Fortschritt-Berichte , vol.152
    • Wahle, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.