메뉴 건너뛰기




Volumn 24, Issue 5, 2000, Pages 373-376

A small pulsatile blood pump for ventricular support during end-stage heart failure

Author keywords

Electromechanical displacement blood pump; Mechanical gear design; Ventricular assist device

Indexed keywords

BLOOD; GEARS; LEFT VENTRICULAR ASSIST DEVICES; PATIENT REHABILITATION; PUMPS;

EID: 0034041002     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.2000.06533.x     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0002955770 scopus 로고    scopus 로고
    • Prospects for implantable circulatory support
    • Akutsu T, Kayanagi H, eds. Tokyo: Springer-Verlag
    • 1. Watson JT. Prospects for implantable circulatory support. In: Akutsu T, Kayanagi H, eds. Heart replacement - artificial heart 6. Tokyo: Springer-Verlag, 1998:3-6.
    • (1998) Heart Replacement - Artificial Heart , vol.6 , pp. 3-6
    • Watson, J.T.1
  • 2
    • 0028064601 scopus 로고
    • The Helmholtz total artificial heart labtype
    • 2. Kaufmann R, Reul H, Rau G. The Helmholtz total artificial heart labtype. Artif Organs 1994;7:537-42.
    • (1994) Artif Organs , vol.7 , pp. 537-542
    • Kaufmann, R.1    Reul, H.2    Rau, G.3
  • 3
    • 0343554675 scopus 로고    scopus 로고
    • A novel implantable electromechanical ventricular assist device, first acute animal testing
    • 3. Kaufmann R, Rakhorst G, Mihaylov D, Elstrodt J, Nix C, Reul H, Rau G. A novel implantable electromechanical ventricular assist device, first acute animal testing. ASAIO J 1997; 43:360-2.
    • (1997) ASAIO J , vol.43 , pp. 360-362
    • Kaufmann, R.1    Rakhorst, G.2    Mihaylov, D.3    Elstrodt, J.4    Nix, C.5    Reul, H.6    Rau, G.7
  • 8
    • 0013655152 scopus 로고    scopus 로고
    • German patent application DE 19726702.5, 1997
    • 8. Kaufmann R, Nix C, Reul H, Rau G. German patent application DE 19726702.5, 1997.
    • Kaufmann, R.1    Nix, C.2    Reul, H.3    Rau, G.4
  • 9
    • 0028070133 scopus 로고
    • Design improvements of the HIA-VAD based on animal experiments
    • 9. Eilers R, Harbott P, Reul H, Rakhorst G, Rau G. Design improvements of the HIA-VAD based on animal experiments. Artif Organs 1994;7:473-8.
    • (1994) Artif Organs , vol.7 , pp. 473-478
    • Eilers, R.1    Harbott, P.2    Reul, H.3    Rakhorst, G.4    Rau, G.5
  • 12
    • 0032404106 scopus 로고    scopus 로고
    • Left ventricular assist devices and the failing heart. A bridge to recovery, a permanent assist device, or a bridge too far?
    • 12. Mann DL, Willerson JT. Left ventricular assist devices and the failing heart. A bridge to recovery, a permanent assist device, or a bridge too far? Circulation 1998;98:2367-9.
    • (1998) Circulation , vol.98 , pp. 2367-2369
    • Mann, D.L.1    Willerson, J.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.