-
1
-
-
0032902372
-
An IgM paraprotein causing a falsely low result in an enzymatic assay for acetaminophen
-
Hullin DA. An IgM paraprotein causing a falsely low result in an enzymatic assay for acetaminophen. Clin Chem. 1999;45:155-156.
-
(1999)
Clin Chem
, vol.45
, pp. 155-156
-
-
Hullin, D.A.1
-
2
-
-
0031309449
-
Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-κ from myeloma patient
-
Yamada K, Yagihashi A, Ishii S, et al. Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-κ from myeloma patient. Clin Chem. 1997;43:2435-2437.
-
(1997)
Clin Chem
, vol.43
, pp. 2435-2437
-
-
Yamada, K.1
Yagihashi, A.2
Ishii, S.3
-
3
-
-
0023990031
-
Falsely elevated values for chloride in serum containing myeloma proteins, measured in the Raramax
-
Schwartz JG, Medina RA. Falsely elevated values for chloride in serum containing myeloma proteins, measured in the Raramax. Clin Chem. 1988;34:771.
-
(1988)
Clin Chem
, vol.34
, pp. 771
-
-
Schwartz, J.G.1
Medina, R.A.2
-
4
-
-
0022443433
-
Interference by IgG paraproteins in the Jaffe method for creatinine determination
-
Datta P, Graham GA, Schoen I. Interference by IgG paraproteins in the Jaffe method for creatinine determination. Am J Clin Pathol. 1986;85:463-468.
-
(1986)
Am J Clin Pathol
, vol.85
, pp. 463-468
-
-
Datta, P.1
Graham, G.A.2
Schoen, I.3
-
5
-
-
0025818014
-
Influence of monoclonal immunoglobulins in direct determinations of iron in serum
-
Bakker AJ. Influence of monoclonal immunoglobulins in direct determinations of iron in serum. Clin Chem. 1991;37:690-694.
-
(1991)
Clin Chem
, vol.37
, pp. 690-694
-
-
Bakker, A.J.1
-
6
-
-
0028912834
-
Elimination of paraprotein interference in determination of plasma inorganic phosphate by ammonium molybdate method
-
Zaman Z, Sneyers L, Orshoven AV, Blanckaert N, Marien G. Elimination of paraprotein interference in determination of plasma inorganic phosphate by ammonium molybdate method. Clin Chem. 1995;41:609-614.
-
(1995)
Clin Chem
, vol.41
, pp. 609-614
-
-
Zaman, Z.1
Sneyers, L.2
Orshoven, A.V.3
Blanckaert, N.4
Marien, G.5
-
7
-
-
0020374176
-
Sodium measurements in multiple myeloma: Two techniques compared
-
Ladenson JH, Apple FS, Aguanno JJ, Koch DD. Sodium measurements in multiple myeloma: two techniques compared. Clin Chem. 1982;28:2383-2386.
-
(1982)
Clin Chem
, vol.28
, pp. 2383-2386
-
-
Ladenson, J.H.1
Apple, F.S.2
Aguanno, J.J.3
Koch, D.D.4
-
8
-
-
0018867005
-
Myeloma immunoglobulin interferes with serum thyroxine analysis by homogeneous enzyme immunoassay
-
Alexander NM, Gattra R, Nishimoto M. Myeloma immunoglobulin interferes with serum thyroxine analysis by homogeneous enzyme immunoassay. Clin Chim Acta. 1980;100:301-305.
-
(1980)
Clin Chim Acta
, vol.100
, pp. 301-305
-
-
Alexander, N.M.1
Gattra, R.2
Nishimoto, M.3
-
9
-
-
0021133297
-
Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: A method-dependent error
-
Whitlow KJ, Nanji AA, Pudek MR. Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: a method-dependent error. Clin Biochem. 1984;17:233-235.
-
(1984)
Clin Biochem
, vol.17
, pp. 233-235
-
-
Whitlow, K.J.1
Nanji, A.A.2
Pudek, M.R.3
-
10
-
-
0026629380
-
Interference with the Astra 8 and Synchron CX3 assays of urea nitrogen in serum by a high-M(r) inhibitor in a patient with multiple myeloma
-
Smith JD, Nobiletti I, Freed M, Malkus H, Donabedian R. Interference with the Astra 8 and Synchron CX3 assays of urea nitrogen in serum by a high-M(r) inhibitor in a patient with multiple myeloma. Clin Chem. 1992;38:598-599.
-
(1992)
Clin Chem
, vol.38
, pp. 598-599
-
-
Smith, J.D.1
Nobiletti, I.2
Freed, M.3
Malkus, H.4
Donabedian, R.5
-
11
-
-
0015993677
-
Faulty haemoglobin values in Sia-positive Waldenstrom's macroglobulinemia
-
Gelinsky P, Braun HJ, Bohner J, Schoeler M. Faulty haemoglobin values in Sia-positive Waldenstrom's macroglobulinemia. Dtsch Med Wochenschr. 1974;99:283-286.
-
(1974)
Dtsch Med Wochenschr
, vol.99
, pp. 283-286
-
-
Gelinsky, P.1
Braun, H.J.2
Bohner, J.3
Schoeler, M.4
-
12
-
-
0023064775
-
Incorrect haemoglobin estimation on the Coulter S+IV in some patients with IgM paraproteins
-
Wallis JP, Ford JM. Incorrect haemoglobin estimation on the Coulter S+IV in some patients with IgM paraproteins. Clin Lab Haematol. 1987;9:95-96.
-
(1987)
Clin Lab Haematol
, vol.9
, pp. 95-96
-
-
Wallis, J.P.1
Ford, J.M.2
-
13
-
-
0027745682
-
Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinaemia: Unusual reaction with monomeric IgM paraprotein
-
Goodrick MJ, Boon RJ, Bishop RJD, Copplestone JA, Prentice AG. Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinaemia: unusual reaction with monomeric IgM paraprotein. J Clin Pathol. 1993;46:1138-1139.
-
(1993)
J Clin Pathol
, vol.46
, pp. 1138-1139
-
-
Goodrick, M.J.1
Boon, R.J.2
Bishop, R.J.D.3
Copplestone, J.A.4
Prentice, A.G.5
-
14
-
-
0024450283
-
Evaluation of 24-second cyanide-containing and cyanide-free methods for whole blood hemoglobin on theTechnicon H*I™ analyzer with normal and abnormal blood samples
-
Malin MJ, Sclafani LD, Wyatt JL Evaluation of 24-second cyanide-containing and cyanide-free methods for whole blood hemoglobin on theTechnicon H*I™ analyzer with normal and abnormal blood samples. Am J Clin Pathol. 1989;92:286-294.
-
(1989)
Am J Clin Pathol
, vol.92
, pp. 286-294
-
-
Malin, M.J.1
Sclafani, L.D.2
Wyatt, J.L.3
-
15
-
-
0029355849
-
Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinemia
-
McMullin MF, Wilkin HJ, Elder E. Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinemia. J Clin Pathol. 1995;48:787.
-
(1995)
J Clin Pathol
, vol.48
, pp. 787
-
-
McMullin, M.F.1
Wilkin, H.J.2
Elder, E.3
-
16
-
-
0017068696
-
Relationship between paraprotein polymerization and clinical features in IgA myeloma
-
Roberts-Thomson PJ, Mason DY, MacLennan IC. Relationship between paraprotein polymerization and clinical features in IgA myeloma. Br J Haematol. 1976;33:117-130.
-
(1976)
Br J Haematol
, vol.33
, pp. 117-130
-
-
Roberts-Thomson, P.J.1
Mason, D.Y.2
MacLennan, I.C.3
-
17
-
-
0030205060
-
Isotypic characterization of IgA paraproteins: Association with other clinical and analytic data
-
Gonzalez GJB, Garcia DR, Camara SE, Ortiz MF. Isotypic characterization of IgA paraproteins: association with other clinical and analytic data. Rev Clin Esp. 1996;196:529-535.
-
(1996)
Rev Clin Esp
, vol.196
, pp. 529-535
-
-
Gonzalez, G.J.B.1
Garcia, D.R.2
Camara, S.E.3
Ortiz, M.F.4
|