메뉴 건너뛰기




Volumn 124, Issue 4, 2000, Pages 616-618

Overestimation of hemoglobin in a patient with an IgA-κ monoclonal gammopathy

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN; IMMUNOGLOBULIN A; PARAPROTEIN;

EID: 0034040581     PISSN: 00039985     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0032902372 scopus 로고    scopus 로고
    • An IgM paraprotein causing a falsely low result in an enzymatic assay for acetaminophen
    • Hullin DA. An IgM paraprotein causing a falsely low result in an enzymatic assay for acetaminophen. Clin Chem. 1999;45:155-156.
    • (1999) Clin Chem , vol.45 , pp. 155-156
    • Hullin, D.A.1
  • 2
    • 0031309449 scopus 로고    scopus 로고
    • Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-κ from myeloma patient
    • Yamada K, Yagihashi A, Ishii S, et al. Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-κ from myeloma patient. Clin Chem. 1997;43:2435-2437.
    • (1997) Clin Chem , vol.43 , pp. 2435-2437
    • Yamada, K.1    Yagihashi, A.2    Ishii, S.3
  • 3
    • 0023990031 scopus 로고
    • Falsely elevated values for chloride in serum containing myeloma proteins, measured in the Raramax
    • Schwartz JG, Medina RA. Falsely elevated values for chloride in serum containing myeloma proteins, measured in the Raramax. Clin Chem. 1988;34:771.
    • (1988) Clin Chem , vol.34 , pp. 771
    • Schwartz, J.G.1    Medina, R.A.2
  • 4
    • 0022443433 scopus 로고
    • Interference by IgG paraproteins in the Jaffe method for creatinine determination
    • Datta P, Graham GA, Schoen I. Interference by IgG paraproteins in the Jaffe method for creatinine determination. Am J Clin Pathol. 1986;85:463-468.
    • (1986) Am J Clin Pathol , vol.85 , pp. 463-468
    • Datta, P.1    Graham, G.A.2    Schoen, I.3
  • 5
    • 0025818014 scopus 로고
    • Influence of monoclonal immunoglobulins in direct determinations of iron in serum
    • Bakker AJ. Influence of monoclonal immunoglobulins in direct determinations of iron in serum. Clin Chem. 1991;37:690-694.
    • (1991) Clin Chem , vol.37 , pp. 690-694
    • Bakker, A.J.1
  • 6
    • 0028912834 scopus 로고
    • Elimination of paraprotein interference in determination of plasma inorganic phosphate by ammonium molybdate method
    • Zaman Z, Sneyers L, Orshoven AV, Blanckaert N, Marien G. Elimination of paraprotein interference in determination of plasma inorganic phosphate by ammonium molybdate method. Clin Chem. 1995;41:609-614.
    • (1995) Clin Chem , vol.41 , pp. 609-614
    • Zaman, Z.1    Sneyers, L.2    Orshoven, A.V.3    Blanckaert, N.4    Marien, G.5
  • 7
    • 0020374176 scopus 로고
    • Sodium measurements in multiple myeloma: Two techniques compared
    • Ladenson JH, Apple FS, Aguanno JJ, Koch DD. Sodium measurements in multiple myeloma: two techniques compared. Clin Chem. 1982;28:2383-2386.
    • (1982) Clin Chem , vol.28 , pp. 2383-2386
    • Ladenson, J.H.1    Apple, F.S.2    Aguanno, J.J.3    Koch, D.D.4
  • 8
    • 0018867005 scopus 로고
    • Myeloma immunoglobulin interferes with serum thyroxine analysis by homogeneous enzyme immunoassay
    • Alexander NM, Gattra R, Nishimoto M. Myeloma immunoglobulin interferes with serum thyroxine analysis by homogeneous enzyme immunoassay. Clin Chim Acta. 1980;100:301-305.
    • (1980) Clin Chim Acta , vol.100 , pp. 301-305
    • Alexander, N.M.1    Gattra, R.2    Nishimoto, M.3
  • 9
    • 0021133297 scopus 로고
    • Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: A method-dependent error
    • Whitlow KJ, Nanji AA, Pudek MR. Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: a method-dependent error. Clin Biochem. 1984;17:233-235.
    • (1984) Clin Biochem , vol.17 , pp. 233-235
    • Whitlow, K.J.1    Nanji, A.A.2    Pudek, M.R.3
  • 10
    • 0026629380 scopus 로고
    • Interference with the Astra 8 and Synchron CX3 assays of urea nitrogen in serum by a high-M(r) inhibitor in a patient with multiple myeloma
    • Smith JD, Nobiletti I, Freed M, Malkus H, Donabedian R. Interference with the Astra 8 and Synchron CX3 assays of urea nitrogen in serum by a high-M(r) inhibitor in a patient with multiple myeloma. Clin Chem. 1992;38:598-599.
    • (1992) Clin Chem , vol.38 , pp. 598-599
    • Smith, J.D.1    Nobiletti, I.2    Freed, M.3    Malkus, H.4    Donabedian, R.5
  • 11
    • 0015993677 scopus 로고
    • Faulty haemoglobin values in Sia-positive Waldenstrom's macroglobulinemia
    • Gelinsky P, Braun HJ, Bohner J, Schoeler M. Faulty haemoglobin values in Sia-positive Waldenstrom's macroglobulinemia. Dtsch Med Wochenschr. 1974;99:283-286.
    • (1974) Dtsch Med Wochenschr , vol.99 , pp. 283-286
    • Gelinsky, P.1    Braun, H.J.2    Bohner, J.3    Schoeler, M.4
  • 12
    • 0023064775 scopus 로고
    • Incorrect haemoglobin estimation on the Coulter S+IV in some patients with IgM paraproteins
    • Wallis JP, Ford JM. Incorrect haemoglobin estimation on the Coulter S+IV in some patients with IgM paraproteins. Clin Lab Haematol. 1987;9:95-96.
    • (1987) Clin Lab Haematol , vol.9 , pp. 95-96
    • Wallis, J.P.1    Ford, J.M.2
  • 13
    • 0027745682 scopus 로고
    • Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinaemia: Unusual reaction with monomeric IgM paraprotein
    • Goodrick MJ, Boon RJ, Bishop RJD, Copplestone JA, Prentice AG. Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinaemia: unusual reaction with monomeric IgM paraprotein. J Clin Pathol. 1993;46:1138-1139.
    • (1993) J Clin Pathol , vol.46 , pp. 1138-1139
    • Goodrick, M.J.1    Boon, R.J.2    Bishop, R.J.D.3    Copplestone, J.A.4    Prentice, A.G.5
  • 14
    • 0024450283 scopus 로고
    • Evaluation of 24-second cyanide-containing and cyanide-free methods for whole blood hemoglobin on theTechnicon H*I™ analyzer with normal and abnormal blood samples
    • Malin MJ, Sclafani LD, Wyatt JL Evaluation of 24-second cyanide-containing and cyanide-free methods for whole blood hemoglobin on theTechnicon H*I™ analyzer with normal and abnormal blood samples. Am J Clin Pathol. 1989;92:286-294.
    • (1989) Am J Clin Pathol , vol.92 , pp. 286-294
    • Malin, M.J.1    Sclafani, L.D.2    Wyatt, J.L.3
  • 15
    • 0029355849 scopus 로고
    • Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinemia
    • McMullin MF, Wilkin HJ, Elder E. Inaccurate haemoglobin estimation in Waldenstrom's macroglobulinemia. J Clin Pathol. 1995;48:787.
    • (1995) J Clin Pathol , vol.48 , pp. 787
    • McMullin, M.F.1    Wilkin, H.J.2    Elder, E.3
  • 16
    • 0017068696 scopus 로고
    • Relationship between paraprotein polymerization and clinical features in IgA myeloma
    • Roberts-Thomson PJ, Mason DY, MacLennan IC. Relationship between paraprotein polymerization and clinical features in IgA myeloma. Br J Haematol. 1976;33:117-130.
    • (1976) Br J Haematol , vol.33 , pp. 117-130
    • Roberts-Thomson, P.J.1    Mason, D.Y.2    MacLennan, I.C.3
  • 17
    • 0030205060 scopus 로고    scopus 로고
    • Isotypic characterization of IgA paraproteins: Association with other clinical and analytic data
    • Gonzalez GJB, Garcia DR, Camara SE, Ortiz MF. Isotypic characterization of IgA paraproteins: association with other clinical and analytic data. Rev Clin Esp. 1996;196:529-535.
    • (1996) Rev Clin Esp , vol.196 , pp. 529-535
    • Gonzalez, G.J.B.1    Garcia, D.R.2    Camara, S.E.3    Ortiz, M.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.