Volumn 10, Issue 2, 2000, Pages 122-130

Investigation of complex phased array coil designs for cardiac imaging

Author keywords

Cardiac imaging; Phased array coils; Simulation

Indexed keywords

ARTICLE; CALCULATION; DIAGNOSTIC IMAGING; GEOMETRY; HEART; PREDICTION; PRIORITY JOURNAL; SIGNAL NOISE RATIO; THEORY;

EID: 0034038672     PISSN: 13528661     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1352-8661(00)00076-4     Document Type: Article
Times cited : (4)

References (13)
  • 1
    • 8244264760 scopus 로고    scopus 로고
    • What is the optimum phased array coil design for cardiac and torso magnetic resonance?
    • Bottomley P.A., Lugo O.C., Giaquinto R. What is the optimum phased array coil design for cardiac and torso magnetic resonance? Magn. Reson. Med. 37:1997;591.
    • (1997) Magn. Reson. Med. , vol.37 , pp. 591
    • Bottomley, P.A.1    Lugo, O.C.2    Giaquinto, R.3
  • 2
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • Constantinides C.D., Atalar E., McVeigh E.R. Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn. Reson. Med. 38:1997;852.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 852
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 4
    • 0000899450 scopus 로고
    • Quick measurement of nmr-coil sensivity with a dual-loop probe
    • Darrasse L., Kassab G. Quick measurement of nmr-coil sensivity with a dual-loop probe. Rev. Sci. Instrum. 64(7):1993;1841.
    • (1993) Rev. Sci. Instrum. , vol.64 , Issue.7 , pp. 1841
    • Darrasse, L.1    Kassab, G.2
  • 5
    • 0030669303 scopus 로고    scopus 로고
    • Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements
    • Debbins J.P., Felmlee J.P., Riederer S.J. Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements. Magn. Reson. Med. 38:1997;1003.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 1003
    • Debbins, J.P.1    Felmlee, J.P.2    Riederer, S.J.3
  • 7
    • 0029099632 scopus 로고
    • An improved quadrature or phasedarray coil for MR cardiac imaging
    • Fayad Z.A., Connick T.J., Axel L. An improved quadrature or phasedarray coil for MR cardiac imaging. Magn. Reson. Med. 34:1995;186.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 186
    • Fayad, Z.A.1    Connick, T.J.2    Axel, L.3
  • 9
    • 0025222891 scopus 로고
    • Noise correlations in data simultaneously acquired from multiple surface coil arrays
    • Hayes C.E., Roemer P.B. Noise correlations in data simultaneously acquired from multiple surface coil arrays. Magn. Reson. Med. 16:1990;181.
    • (1990) Magn. Reson. Med. , vol.16 , pp. 181
    • Hayes, C.E.1    Roemer, P.B.2
  • 10
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • Hoult D.I., Richards R.E. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J. Magn. Res. 24:1976;71.
    • (1976) J. Magn. Res. , vol.24 , pp. 71
    • Hoult, D.I.1    Richards, R.E.2
  • 12
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson D.K., Manning W.J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 38:1997;591.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591
    • Sodickson, D.K.1    Manning, W.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.