Design and validation of a machine for reproducible precision insertion of femoral hip prostheses for preclinical testing

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BONE RADIOGRAPHY; HIP PROSTHESIS; MACHINE; REPRODUCIBILITY; VALIDATION PROCESS;

EID: 0034030695     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.429645     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0343955292 scopus 로고
    • Artificial proximal femur of fiber reinforced polyester for the study of load transmission of cemented hip prostheses: The prosthesis cement interface
    • Nicderer, P. G., Chiquet, C., Frey, O., and Semlitsch, M., 1978, "Artificial Proximal Femur of Fiber Reinforced Polyester for the Study of Load Transmission of Cemented Hip Prostheses: the Prosthesis Cement Interface," Biomaterials, 1, pp. 88-89.
    • (1978) Biomaterials , vol.1 , pp. 88-89
    • Nicderer, P.G.1    Chiquet, C.2    Frey, O.3    Semlitsch, M.4
  • 2
    • 0026311111 scopus 로고
    • Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance
    • Szivek, J. A., and Gealer, R. L., 1991, "Comparison of the Deformation Response of Synthetic and Cadaveric Femora During Simulated One-Legged Stance." J. Appl. Bio., 2, pp. 277-280.
    • (1991) J. Appl. Bio. , vol.2 , pp. 277-280
    • Szivek, J.A.1    Gealer, R.L.2
  • 3
    • 0017081806 scopus 로고
    • A stress analysis of the femoral stem in total hip prostheses
    • Andriacchi, T. P., Galante, J. O., Belytschko, T. B., and Hampton, S., 1976, "A Stress Analysis of the Femoral Stem in Total Hip Prostheses," J. Bone Jt. Surg., 58-A, No. 5, pp. 618-624.
    • (1976) J. Bone Jt. Surg. , vol.58 A , Issue.5 , pp. 618-624
    • Andriacchi, T.P.1    Galante, J.O.2    Belytschko, T.B.3    Hampton, S.4
  • 4
    • 0028197479 scopus 로고
    • Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure
    • Star, M. J., Colwell, C. W., Kelman, G. J., Ballock, R. T., and Walker, R. H., 1994, "Suboptimal (Thin) Distal Cement Mantle Thickness as a Contributory Factor in Total Hip Arthroplasty Femoral Component Failure," J. Arthrop., 9, No. 2, pp. 143-149.
    • (1994) J. Arthrop. , vol.9 , Issue.2 , pp. 143-149
    • Star, M.J.1    Colwell, C.W.2    Kelman, G.J.3    Ballock, R.T.4    Walker, R.H.5
  • 5
    • 0021192353 scopus 로고
    • Effect of cement pressure and bone strength on polymethylmethacrylate fixation
    • Askew, M. J., Steege, J. W., Lewis, J. L., Ranieri, J. R., and Wixson, R. L., 1984, "Effect of Cement Pressure and Bone Strength on Polymethylmethacrylate Fixation," J. Orthop. Res., 1, No. 4, pp. 412-420.
    • (1984) J. Orthop. Res. , vol.1 , Issue.4 , pp. 412-420
    • Askew, M.J.1    Steege, J.W.2    Lewis, J.L.3    Ranieri, J.R.4    Wixson, R.L.5
  • 6
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement
    • Mulroy, R. D., and Harris, W. H., 1990, "The Effect of Improved Cementing Techniques on Component Loosening in Total Hip Replacement," J. Bone Jt. Surg., 72-B, pp. 757-760.
    • (1990) J. Bone Jt. Surg. , vol.72 B , pp. 757-760
    • Mulroy, R.D.1    Harris, W.H.2
  • 8
    • 0031719836 scopus 로고    scopus 로고
    • Primary and revision total hip replacement using the Robodoc® system
    • Bargar, W. L., Bauer, A., and Borner, M., 1998, "Primary and Revision Total Hip Replacement Using the Robodoc® System," Clin. Orthop. Relat. Res., 354, pp. 82-91.
    • (1998) Clin. Orthop. Relat. Res. , vol.354 , pp. 82-91
    • Bargar, W.L.1    Bauer, A.2    Borner, M.3
  • 9
    • 0017053093 scopus 로고
    • In vitro measurement of bone-acrylic interface pressure during femoral component insertion
    • Markolf, K. L., and Amstutz, H. C., 1976, "In Vitro Measurement of Bone-Acrylic Interface Pressure During Femoral Component Insertion," Clin. Orthop. Relat. Res., 121, pp. 60-66.
    • (1976) Clin. Orthop. Relat. Res. , vol.121 , pp. 60-66
    • Markolf, K.L.1    Amstutz, H.C.2
  • 10
    • 0028414135 scopus 로고
    • Computer-controlled experimental implantation technique comparing the quality of different types of cement application into the femoral canal in cemented hip arthroplasty
    • Schmidt, J., Steur, G., Specht, R., and Kumm, D., 1994, "Computer-Controlled Experimental Implantation Technique Comparing the Quality of Different Types of Cement Application Into the Femoral Canal in Cemented Hip Arthroplasty," Biomed. Tec., 39(4), pp. 79-84.
    • (1994) Biomed. Tec. , vol.39 , Issue.4 , pp. 79-84
    • Schmidt, J.1    Steur, G.2    Specht, R.3    Kumm, D.4
  • 11
    • 0031762032 scopus 로고    scopus 로고
    • Effects of design changes on cemented tapered femoral stem fixation
    • Middleton, R. J. Howie, D. W., Costi, K., and Sharpe, P., 1998, "Effects of Design Changes on Cemented Tapered Femoral Stem Fixation," Clin. Orthop. Relat. Res., 355, pp 47-56
    • (1998) Clin. Orthop. Relat. Res. , vol.355 , pp. 47-56
    • Middleton, R.J.1    Howie, D.W.2    Costi, K.3    Sharpe, P.4
  • 12
    • 0027669981 scopus 로고
    • Stem curvature and load angle influence the initial relative bone-implant motion of cementless femoral stems
    • Berzins, A., Sumner, D. R., Andriacchi, T. P., and Galante, J. O., 1993, "Stem Curvature and Load Angle Influence the Initial Relative Bone-Implant Motion of Cementless Femoral Stems," J. Orthop. Res., 11, No. 5, pp. 758-769.
    • (1993) J. Orthop. Res. , vol.11 , Issue.5 , pp. 758-769
    • Berzins, A.1    Sumner, D.R.2    Andriacchi, T.P.3    Galante, J.O.4
  • 14
    • 0024463988 scopus 로고
    • Experimental method for the in vitro testing of the initial stability of cementless hip prostheses
    • Schneider, E., Eulenberger, J., Steiner, W., Wyder, D., Friedman, R. J., and Perren, S. M., 1989, "Experimental Method for the In Vitro Testing of the Initial Stability of Cementless Hip Prostheses," J. Biomech., 22, pp. 735-744.
    • (1989) J. Biomech. , vol.22 , pp. 735-744
    • Schneider, E.1    Eulenberger, J.2    Steiner, W.3    Wyder, D.4    Friedman, R.J.5    Perren, S.M.6
  • 15
    • 0029435608 scopus 로고
    • Roentgen stereophotogrammetric analysis for assessing migration of total hip replacement femoral components
    • Kiss, J., Murray, D. W., Turner-Smith, A. R., and Bulstrode, C. J., 1995, "Roentgen Stereophotogrammetric Analysis for Assessing Migration of Total Hip Replacement Femoral Components," J. Eng. Med., 209, pp. 169-175.
    • (1995) J. Eng. Med. , vol.209 , pp. 169-175
    • Kiss, J.1    Murray, D.W.2    Turner-Smith, A.R.3    Bulstrode, C.J.4
  • 16
    • 0342649188 scopus 로고
    • Implants for surgery - Partial and total hip joint prostheses - Part 3: Determination of endurance properties of stemmed femoral components without application of torsion
    • International Standards Organisation, 1988, "Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 3: Determination of Endurance Properties of Stemmed Femoral Components Without Application of Torsion," ISO 7206-3:(E).
    • (1988) ISO 7206-3:(E)