메뉴 건너뛰기




Volumn 41, Issue 4, 2000, Pages 745-754

ROC and LROC analyses of the effects of lesion contrast, size, and signal-to-noise ratio on detectability in PET images

Author keywords

Contrast; Lesion detection; Receiver operating characteristic analysis; Signal to noise ratio

Indexed keywords

ARTICLE; CONTRAST; IMAGE QUALITY; PHANTOM; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; SIGNAL NOISE RATIO;

EID: 0034029854     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (37)

References (13)
  • 1
    • 0028286963 scopus 로고
    • Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner
    • Kinahan PE, Karp JS. Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner Phys Med Biol. 1994;39:631-642.
    • (1994) Phys Med Biol , vol.39 , pp. 631-642
    • Kinahan, P.E.1    Karp, J.S.2
  • 2
    • 0029822853 scopus 로고    scopus 로고
    • Unified measurement of observer performance in detecting and localizing target objects on images
    • Swensson RG. Unified measurement of observer performance in detecting and localizing target objects on images. Med Phys. 1996;23:1709-1725.
    • (1996) Med Phys , vol.23 , pp. 1709-1725
    • Swensson, R.G.1
  • 3
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • Metz CE. ROC methodology in radiologic imaging. Invest Radiol. 1986;21:720-733.
    • (1986) Invest Radiol , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 4
    • 0019405245 scopus 로고
    • Lesion detection and signal-to-noise ratio in CT images
    • Judy PF, Swensson RG, Szulc M. Lesion detection and signal-to-noise ratio in CT images. Med Phys. 1981;8;13-23.
    • (1981) Med Phys , vol.8 , pp. 13-23
    • Judy, P.F.1    Swensson, R.G.2    Szulc, M.3
  • 5
    • 0018924603 scopus 로고
    • Detection of low-contrast lesions in computed body tomography: An experimental study of simulated lesions
    • Meaney TF, Raudkivi U, McIntyre WJ, et al. Detection of low-contrast lesions in computed body tomography: an experimental study of simulated lesions. Radiology. 1980;134:149-154.
    • (1980) Radiology , vol.134 , pp. 149-154
    • Meaney, T.F.1    Raudkivi, U.2    McIntyre, W.J.3
  • 6
    • 0019524821 scopus 로고
    • Image noise, resolution, and lesion detectability in single photon emission CT
    • Lim CB, Kyung SH, Hawman EG, Jaszczak RJ. Image noise, resolution, and lesion detectability in single photon emission CT. IEEE Trans Nucl Sci. 1982;29:500-505.
    • (1982) IEEE Trans Nucl Sci , vol.29 , pp. 500-505
    • Lim, C.B.1    Kyung, S.H.2    Hawman, E.G.3    Jaszczak, R.J.4
  • 7
    • 0024511244 scopus 로고
    • Some practical issues of experimental design and data analysis in radiological ROC studies
    • Metz CE. Some practical issues of experimental design and data analysis in radiological ROC studies. Invest Radiol. 1989;24:234-245.
    • (1989) Invest Radiol , vol.24 , pp. 234-245
    • Metz, C.E.1
  • 8
    • 0002167042 scopus 로고
    • A new approach for testing the significance of differences between ROC curves measured from correlated data
    • Deconinck H, ed. The Hague, Netherlands: Martinus Nijhoff
    • Metz CE, Wang PL, Kronman HB. A new approach for testing the significance of differences between ROC curves measured from correlated data. In: Deconinck H, ed. Information Processing in Medical Imaging. The Hague, Netherlands: Martinus Nijhoff; 1984:432-445.
    • (1984) Information Processing in Medical Imaging , pp. 432-445
    • Metz, C.E.1    Wang, P.L.2    Kronman, H.B.3
  • 9
    • 0024503751 scopus 로고
    • Measuring observer performance by ROC analysis: Indications and complications
    • Berbaum KS, Dorfman DD, Franken EA Jr. Measuring observer performance by ROC analysis: indications and complications. Invest Radiol 1989;24:228-233.
    • (1989) Invest Radiol , vol.24 , pp. 228-233
    • Berbaum, K.S.1    Dorfman, D.D.2    Franken E.A., Jr.3
  • 10
    • 0026664983 scopus 로고
    • Generalization to the population of readers and patients with the jackknife method
    • Dorfman DD, Berbaum KS, Metz CE. Generalization to the population of readers and patients with the jackknife method. Invest Radiol. 1992;27:723-731.
    • (1992) Invest Radiol , vol.27 , pp. 723-731
    • Dorfman, D.D.1    Berbaum, K.S.2    Metz, C.E.3
  • 11
    • 0018367149 scopus 로고
    • Quantitation in positron emission computed tomography: 1. Effect of object size
    • Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299-308.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 12
    • 0019143158 scopus 로고
    • Quantitation in positron emission computed tomography: 3. Effect of sampling
    • Huang SC, Hoffman EJ, Phelps ME, Kuhl DE. Quantitation in positron emission computed tomography: 3. Effect of sampling. J Comput Assist Tomogr. 1980;4:819-826.
    • (1980) J Comput Assist Tomogr , vol.4 , pp. 819-826
    • Huang, S.C.1    Hoffman, E.J.2    Phelps, M.E.3    Kuhl, D.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.