메뉴 건너뛰기




Volumn 50, Issue 3, 2000, Pages 313-321

Swelling and delamination of multi-electrode sensor arrays studied by variable-pressure scanning electron microscopy

Author keywords

Delamination; Low vacuum SEM; Multi electrode sensor array; Peel stresses; Swelling

Indexed keywords

CALCIUM; DELAMINATION; ENERGY DISPERSIVE SPECTROSCOPY; HYDRATION; MEMBRANES; MORPHOLOGY; POTASSIUM; SCANNING ELECTRON MICROSCOPY; SODIUM; SWELLING;

EID: 0034028380     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(20000605)50:3<313::AID-JBM4>3.0.CO;2-V     Document Type: Article
Times cited : (5)

References (15)
  • 3
    • 0029638855 scopus 로고
    • Characterization of regenerated silk fibroin membranes for immobilizing glucose-oxidase and construction of a tetrathiafulvalene-mediating glucose sensor
    • Yu TY, Liu HY, Deng JQ, Liu YC. Characterization of regenerated silk fibroin membranes for immobilizing glucose-oxidase and construction of a tetrathiafulvalene-mediating glucose sensor. J Appl Polym Sci 1995;58(6):973-980.
    • (1995) J Appl Polym Sci , vol.58 , Issue.6 , pp. 973-980
    • Yu, T.Y.1    Liu, H.Y.2    Deng, J.Q.3    Liu, Y.C.4
  • 5
    • 0001156237 scopus 로고
    • Ion-selective microchemical sensors with reduced preconditioning time-membrane biostability studies and applications in blood analysis
    • Cosofret VV, Erdosy M, Linder E, Johnson TJ, Buck RP, Kao WJ, Neuman MR, Anderson JM. Ion-selective microchemical sensors with reduced preconditioning time-membrane biostability studies and applications in blood analysis. Anal Lett 1994;27(15):3039-3063.
    • (1994) Anal Lett , vol.27 , Issue.15 , pp. 3039-3063
    • Cosofret, V.V.1    Erdosy, M.2    Linder, E.3    Johnson, T.J.4    Buck, R.P.5    Kao, W.J.6    Neuman, M.R.7    Anderson, J.M.8
  • 6
    • 0029088665 scopus 로고
    • Electroanalytical and surface characterization of encapsulated implantable membrane planar microsensors
    • Cosofret VV, Erdosy M, Johnson TJ, Bellinger DA, Ash RB, Neuman MR. Electroanalytical and surface characterization of encapsulated implantable membrane planar microsensors. Anal Chim Acta 1995;314:1-11.
    • (1995) Anal Chim Acta , vol.314 , pp. 1-11
    • Cosofret, V.V.1    Erdosy, M.2    Johnson, T.J.3    Bellinger, D.A.4    Ash, R.B.5    Neuman, M.R.6
  • 7
    • 0028439484 scopus 로고
    • Ion-selective membranes with low plasticizer content-electroanalytical characterization and biocompatibility studies
    • Linder E, Cosofret VV, Ufer S, Buck RP, Kao WJ, Neuman MR, Anderson JM. Ion-selective membranes with low plasticizer content-electroanalytical characterization and biocompatibility studies. J Biomed Mater Res 1994;28(5):591-601.
    • (1994) J Biomed Mater Res , vol.28 , Issue.5 , pp. 591-601
    • Linder, E.1    Cosofret, V.V.2    Ufer, S.3    Buck, R.P.4    Kao, W.J.5    Neuman, M.R.6    Anderson, J.M.7
  • 11
    • 0003961210 scopus 로고    scopus 로고
    • New York: Taylor and Francis
    • th ed. New York: Taylor and Francis; 1996. p 56.
    • (1996) th Ed. , pp. 56
    • Rodriguez, F.1
  • 14
    • 0343682211 scopus 로고
    • Recent advances in adhesion
    • Lee LH. Recent advances in adhesion. Proc Am Chem Soc 1973:381.
    • (1973) Proc Am Chem Soc , pp. 381
    • Lee, L.H.1
  • 15
    • 0343682213 scopus 로고    scopus 로고
    • SENDX Inc. Private communication
    • SENDX Inc. Private communication.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.