메뉴 건너뛰기




Volumn 18, Issue 3, 2000, Pages 273-277

The stability of arterial blood gases during transportation of patients using the RespirTech PRO

Author keywords

Patient transport; Respiratory support; Resuscitator; Ventilator

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL VENTILATION; BLOOD GAS ANALYSIS; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CRITICAL ILLNESS; FEMALE; HUMAN; MALE; PATIENT MONITORING; PATIENT TRANSPORT; PRIORITY JOURNAL; RELIABILITY; VENTILATOR;

EID: 0034026148     PISSN: 07356757     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0735-6757(00)90121-9     Document Type: Article
Times cited : (11)

References (7)
  • 1
    • 0023572123 scopus 로고
    • Comparison of blood gases of ventilated patients during transport
    • Gervais HW, Eberle B, Konietzke D, et al: Comparison of blood gases of ventilated patients during transport. Crit Care Med 1987;15: 761-763
    • (1987) Crit Care Med , vol.15 , pp. 761-763
    • Gervais, H.W.1    Eberle, B.2    Konietzke, D.3
  • 2
    • 0023636487 scopus 로고
    • Complications of intrahospital transport in critically ill patients
    • Braman SS, Dunn SM, Amico CA, et al: Complications of intrahospital transport in critically ill patients. Ann Intern Med 1987;107: 469-73
    • (1987) Ann Intern Med , vol.107 , pp. 469-473
    • Braman, S.S.1    Dunn, S.M.2    Amico, C.A.3
  • 3
    • 0024786759 scopus 로고
    • Comparison of blood gases during transport using two methods of ventilatory support
    • Hurst JM, Davis K, Jr., Branson RD, et al: Comparison of blood gases during transport using two methods of ventilatory support. J Trauma 1989;29:1637-1640
    • (1989) J Trauma , vol.29 , pp. 1637-1640
    • Hurst, J.M.1    Davis Jr., K.2    Branson, R.D.3
  • 4
    • 0032043453 scopus 로고    scopus 로고
    • Comparison of automated and manual ventilation in a prehospital pediatric model
    • Auble TE, Menegazzi JJ, Nicklas KA: Comparison of automated and manual ventilation in a prehospital pediatric model. Prehosp Emerg Care 1998;2:108-111
    • (1998) Prehosp Emerg Care , vol.2 , pp. 108-111
    • Auble, T.E.1    Menegazzi, J.J.2    Nicklas, K.A.3
  • 5
    • 0030757829 scopus 로고    scopus 로고
    • Portable power supply for continuous mechanical ventilation during intrahospital transport of critically ill patients with ARDS
    • Barton ACH, Tuttle-Newhall JE, Szalados JE: Portable power supply for continuous mechanical ventilation during intrahospital transport of critically ill patients with ARDS. Chest 1997;112:560-563
    • (1997) Chest , vol.112 , pp. 560-563
    • Barton, A.C.H.1    Tuttle-Newhall, J.E.2    Szalados, J.E.3
  • 6
    • 0030039946 scopus 로고    scopus 로고
    • Sudden severe barotrauma from self-inflating bag valve devices
    • Silbergleit R, Lee DC, Blankreid C, et al: Sudden severe barotrauma from self-inflating bag valve devices. J Trauma 1996;40: 320-322
    • (1996) J Trauma , vol.40 , pp. 320-322
    • Silbergleit, R.1    Lee, D.C.2    Blankreid, C.3
  • 7
    • 85031638086 scopus 로고    scopus 로고
    • Comparison of RespirTech PRO and valved-bag resuscitators during simulated CPR chest compression
    • submitted
    • Raabe, OG: Comparison of RespirTech PRO and valved-bag resuscitators during simulated CPR chest compression. Respir Care (submitted)
    • Respir Care
    • Raabe, O.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.