메뉴 건너뛰기




Volumn 11, Issue 5, 2000, Pages 549-558

A generalized k-sampling scheme for 3D fast spin echo

Author keywords

Fast spin echo; Magnetic resonance imaging; Phase encoding scheme

Indexed keywords

ANISOTROPY; ARTICLE; ARTIFACT; COMPUTER SIMULATION; IN VIVO STUDY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING;

EID: 0034025468     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(200005)11:5<549::AID-JMRI11>3.0.CO;2-G     Document Type: Article
Times cited : (17)

References (19)
  • 3
    • 0031877409 scopus 로고    scopus 로고
    • Intracranial black-blood MR angiography with high-resolution 3D fast spin echo
    • Alexander AL, Buswell HR, Sun Y, et al. Intracranial black-blood MR angiography with high-resolution 3D fast spin echo. Magn Reson Med 1998;40:298-310.
    • (1998) Magn Reson Med , vol.40 , pp. 298-310
    • Alexander, A.L.1    Buswell, H.R.2    Sun, Y.3
  • 5
    • 0031403931 scopus 로고    scopus 로고
    • A segmentinterleaved motion-compensated acquisition in the steady state (SIMCAST) technique for high resolution imaging of the inner ear
    • Kurucay S, Schmalbrock P, Chakeres DW, Keller PJ. A segmentinterleaved motion-compensated acquisition in the steady state (SIMCAST) technique for high resolution imaging of the inner ear. J Magn Reson Imaging 1997;7:1060-1068.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 1060-1068
    • Kurucay, S.1    Schmalbrock, P.2    Chakeres, D.W.3    Keller, P.J.4
  • 7
    • 0032955684 scopus 로고    scopus 로고
    • Evaluation of the inner ear by 3D fast asymmetric spin echo (FASE) MR imaging: Phantom and volunteer studies
    • Yang D, Kodama T, Tamura S, Watanabe K. Evaluation of the inner ear by 3D fast asymmetric spin echo (FASE) MR imaging: phantom and volunteer studies. Magn Reson Imaging 1999;17:171-182.
    • (1999) Magn Reson Imaging , vol.17 , pp. 171-182
    • Yang, D.1    Kodama, T.2    Tamura, S.3    Watanabe, K.4
  • 8
    • 0025050629 scopus 로고
    • Contrast manipulation and artifact assessment of 2D and 3D RARE sequences
    • Mulkern RV, Wong STS, Winalski C, Jolesz FA. Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. Magn Reson Imaging 1990;8:557-566.
    • (1990) Magn Reson Imaging , vol.8 , pp. 557-566
    • Mulkern, R.V.1    Wong, S.T.S.2    Winalski, C.3    Jolesz, F.A.4
  • 9
    • 0026467251 scopus 로고
    • The loss of small objects in variable TE imaging: Implications for FSE, RARE, and EPI
    • Constable RT, Gore JC. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 1992;28:9-24.
    • (1992) Magn Reson Med , vol.28 , pp. 9-24
    • Constable, R.T.1    Gore, J.C.2
  • 11
    • 0023984389 scopus 로고
    • Reconstruction by weighted correlation for MRI with time-varying gradients
    • Maeda A, Sano K, Yokoyama T. Reconstruction by weighted correlation for MRI with time-varying gradients. IEEE Trans Med Imaging 1988;MI-7:26-31.
    • (1988) IEEE Trans Med Imaging , vol.MI-7 , pp. 26-31
    • Maeda, A.1    Sano, K.2    Yokoyama, T.3
  • 12
    • 0027669438 scopus 로고
    • Reduction of ringing and blurring artifacts in fast spin-echo imaging
    • Zhou X, Liang ZP, Cofer GP, et al. Reduction of ringing and blurring artifacts in fast spin-echo imaging. J Magn Reson Imaging 1993;3: 803-807.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 803-807
    • Zhou, X.1    Liang, Z.P.2    Cofer, G.P.3
  • 13
    • 0000811634 scopus 로고
    • Multiecho imaging sequences with low refocusing flip angle
    • Hennig J. Multiecho imaging sequences with low refocusing flip angle. J Magn Reson 1988;78:397-407.
    • (1988) J Magn Reson , vol.78 , pp. 397-407
    • Hennig, J.1
  • 14
    • 0027258904 scopus 로고
    • Stabilization of echo amplitudes in FSE sequences
    • LeRoux P, Hinks RS. Stabilization of echo amplitudes in FSE sequences. Magn Reson Med 1993;30:183-191.
    • (1993) Magn Reson Med , vol.30 , pp. 183-191
    • LeRoux, P.1    Hinks, R.S.2
  • 15
    • 0031022460 scopus 로고    scopus 로고
    • The sensitivity of low flip angle RARE imaging
    • Alsop DC. The sensitivity of low flip angle RARE imaging. Magn Reson Med 1997;37:176-184.
    • (1997) Magn Reson Med , vol.37 , pp. 176-184
    • Alsop, D.C.1
  • 19
    • 0030705199 scopus 로고    scopus 로고
    • Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging
    • Wilman AH, Riederer SJ. Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging. Magn Reson Med 1997;38:793-802.
    • (1997) Magn Reson Med , vol.38 , pp. 793-802
    • Wilman, A.H.1    Riederer, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.