메뉴 건너뛰기




Volumn 6, Issue 3, 2000, Pages 135-139

Influence of factor VIII:C and factor IX activity in plasmas of haemophilic dogs on the activated partial thromboplastin time measured with two commercial reagents

Author keywords

Activated partial thromboplastin time; Dog; Factor IX sensitivity; Factor VIII:C sensitivity

Indexed keywords

BLOOD CLOTTING FACTOR 8C; BLOOD CLOTTING FACTOR 9; KAOLIN;

EID: 0034024657     PISSN: 13518216     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2516.2000.00392.x     Document Type: Article
Times cited : (7)

References (17)
  • 1
    • 72949143661 scopus 로고
    • The partial thromboplastin time with kaolin: A simple screening test for first stage plasma clotting factor deficiencies
    • Proctor RR, Rapaport SI. The partial thromboplastin time with kaolin: a simple screening test for first stage plasma clotting factor deficiencies. Am J Clin Pathol 1961; 36: 212-9.
    • (1961) Am J Clin Pathol , vol.36 , pp. 212-219
    • Proctor, R.R.1    Rapaport, S.I.2
  • 2
    • 0029012710 scopus 로고
    • Hemophilia B (factor IX deficiency) in a family of German Shepherd dogs
    • Feldman DG, Brooks MB, Dodds WJ. Hemophilia B (factor IX deficiency) in a family of German Shepherd dogs. J Am Vet Med Assoc 1995; 206: 1901-5.
    • (1995) J Am Vet Med Assoc , vol.206 , pp. 1901-1905
    • Feldman, D.G.1    Brooks, M.B.2    Dodds, W.J.3
  • 3
    • 0029681730 scopus 로고    scopus 로고
    • Hemophilia A in a German shorthaired pointer: Clinical presentations and diagnosis
    • Joseph SA, Brooks MB, Coccari PJ, Riback SC. Hemophilia A in a German shorthaired pointer: clinical presentations and diagnosis. J Am Anim Hosp Assoc 1996; 32: 25-8.
    • (1996) J Am Anim Hosp Assoc , vol.32 , pp. 25-28
    • Joseph, S.A.1    Brooks, M.B.2    Coccari, P.J.3    Riback, S.C.4
  • 6
    • 0024507936 scopus 로고
    • Die aktivierte partielle Thromboplastinzeit (APTT) als Screeningtest für leichte Gerinnungsfaktorenmängel - Untersuchungen zur Sensitivität von verschiedenen Reagenzien
    • Hellstern P, Oberfrank K, Köhler M, Heinkel K, Wenzel E. Die aktivierte partielle Thromboplastinzeit (APTT) als Screeningtest für leichte Gerinnungsfaktorenmängel - Untersuchungen zur Sensitivität von verschiedenen Reagenzien. Lab Med 1989; 13: 83-6.
    • (1989) Lab Med , vol.13 , pp. 83-86
    • Hellstern, P.1    Oberfrank, K.2    Köhler, M.3    Heinkel, K.4    Wenzel, E.5
  • 8
    • 0027074196 scopus 로고
    • A comparison of different APTT-reagents, heparin-sensitivity and detection of mild coagulopathies
    • Lindhoff-Last E, Krzywanek HJ, Mosch G, Breddin HK. A comparison of different APTT-reagents, heparin-sensitivity and detection of mild coagulopathies. Lab Med 1992; 16: 423-6.
    • (1992) Lab Med , vol.16 , pp. 423-426
    • Lindhoff-Last, E.1    Krzywanek, H.J.2    Mosch, G.3    Breddin, H.K.4
  • 9
    • 0022187026 scopus 로고
    • Normal values of coagulation in canine blood
    • Zondag ACP, Kolb AM, Bax NMA. Normal values of coagulation in canine blood. Haemostasis 1985; 15: 318-23.
    • (1985) Haemostasis , vol.15 , pp. 318-323
    • Zondag, A.C.P.1    Kolb, A.M.2    Bax, N.M.A.3
  • 11
    • 0023913090 scopus 로고
    • Comparison of activated partial thromboplastin time reagents
    • Pedersen JT, Pincus MR, Rapiejko JA. Comparison of activated partial thromboplastin time reagents. Lab Med 1988; 19: 421-4.
    • (1988) Lab Med , vol.19 , pp. 421-424
    • Pedersen, J.T.1    Pincus, M.R.2    Rapiejko, J.A.3
  • 12
    • 0028310286 scopus 로고
    • Ein neues Reagens für die Bestimmung der aktivierten partiellen Thromboplastinzeit, optimiert für das Automated Coagulation Laboratory
    • Heins M, Vazzana S, Botta E, Papagni M. Ein neues Reagens für die Bestimmung der aktivierten partiellen Thromboplastinzeit, optimiert für das Automated Coagulation Laboratory. Lab Med 1994; 18: 190-5.
    • (1994) Lab Med , vol.18 , pp. 190-195
    • Heins, M.1    Vazzana, S.2    Botta, E.3    Papagni, M.4
  • 13
    • 0019166316 scopus 로고
    • Activated partial thromboplastin time. A multicenter evaluation of 11 reagents in the screening of mild haemophilia A
    • Italian (C.I.S.M.E.L.) Study Group. Activated partial thromboplastin time. A multicenter evaluation of 11 reagents in the screening of mild haemophilia A. Scand J Haematol 1980; 25: 308-7.
    • (1980) Scand J Haematol , vol.25 , pp. 308-317
  • 14
    • 0022335189 scopus 로고
    • Partial thromboplastin time reagents: Another look
    • Bauman L, Zimmerman TS. Partial thromboplastin time reagents: another look. Lab Med 1985; 16: 35-7.
    • (1985) Lab Med , vol.16 , pp. 35-37
    • Bauman, L.1    Zimmerman, T.S.2
  • 16
    • 0005844086 scopus 로고
    • A multicenter evaluation of partial thromboplastin time reagents in the detection of mild haemophiliacs
    • Triplett DA, ed. Skokie, Illinois: College of American Pathologists
    • Mannucci PM. A multicenter evaluation of partial thromboplastin time reagents in the detection of mild haemophiliacs. In: Triplett DA, ed. Standardisation of Coagulation Assays: An Overview Skokie, Illinois: College of American Pathologists, 1982: 165-77.
    • (1982) Standardisation of Coagulation Assays: An Overview , pp. 165-177
    • Mannucci, P.M.1
  • 17
    • 0022483164 scopus 로고
    • The reliability of activated partial thromboplastin time methods and the relationship to lipid composition and ultrastructure
    • Stevenson KJ, Easton AC, Curry A. The reliability of activated partial thromboplastin time methods and the relationship to lipid composition and ultrastructure. Thromb Haemost 1986; 55: 250-8.
    • (1986) Thromb Haemost , vol.55 , pp. 250-258
    • Stevenson, K.J.1    Easton, A.C.2    Curry, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.