메뉴 건너뛰기




Volumn 40, Issue 2, 2000, Pages 168-175

Volumetric analysis and visualization of cardiac ultrasound data;Volumetrische analyse und visualisierung kardiologischer ultraschalldaten

Author keywords

Echocardiography; Heart valve disease; Image processing; Virtual reality

Indexed keywords

ARTICLE; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; HEART LEFT ATRIUM; HEART VALVE REGURGITATION; HEART VOLUME; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; MAJOR CLINICAL STUDY; OPTICAL RESOLUTION; VOLUMETRY;

EID: 0034022153     PISSN: 0033832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001170050027     Document Type: Article
Times cited : (4)

References (27)
  • 1
    • 0033104206 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic analysis of valve anatomy as a determinant of mitral regurgitation after surgery for atrioventricular septal defects
    • Acar P, Laskari C, Rhodes J, Pandian N, Warner K, Marx G Am (1999 ) Three-dimensional echocardiographic analysis of valve anatomy as a determinant of mitral regurgitation after surgery for atrioventricular septal defects. J Cardiol 83:745-749
    • (1999) J Cardiol , vol.83 , pp. 745-749
    • Acar, P.1    Laskari, C.2    Rhodes, J.3    Pandian, N.4    Warner, K.5    Marx, G.Am.6
  • 2
    • 0033062263 scopus 로고    scopus 로고
    • Quantitative assessment of chronic aortic regurgitation with 3-dimensional echocardiographic reconstruction: Comparison with electromagnetic flowmeter measurements
    • Acar P, Jones M, Shiota T, Masani N, Delabays A, Yamada I, Sahn DJ, Pandian NG (1999) Quantitative assessment of chronic aortic regurgitation with 3-dimensional echocardiographic reconstruction: comparison with electromagnetic flowmeter measurements. J Am Soc Echocardiogr 12:138-148
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 138-148
    • Acar, P.1    Jones, M.2    Shiota, T.3    Masani, N.4    Delabays, A.5    Yamada, I.6    Sahn, D.J.7    Pandian, N.G.8
  • 3
    • 0031751172 scopus 로고    scopus 로고
    • Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: An in vitro study
    • Aida S, Shiota T, Tsujino H, Sahn DJ (1998) Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: an in vitro study. J Am Soc Echocardiogr 11:874-881
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 874-881
    • Aida, S.1    Shiota, T.2    Tsujino, H.3    Sahn, D.J.4
  • 4
    • 84965761404 scopus 로고
    • Multiple resolution Bayesian segmentation of ultrasound images
    • Ashton EA, Parker KJ (1995) Multiple resolution Bayesian segmentation of ultrasound images. Ultrason Imaging 17:291-304
    • (1995) Ultrason Imaging , vol.17 , pp. 291-304
    • Ashton, E.A.1    Parker, K.J.2
  • 6
    • 0343670037 scopus 로고
    • Impact of impinging wall jet on color Doppler quantification of mitral regurgitation
    • Chen C, Thomas JD, Anconina J et al. (1991) Impact of impinging wall jet on color Doppler quantification of mitral regurgitation. Circulation 67:571-581
    • (1991) Circulation , vol.67 , pp. 571-581
    • Chen, C.1    Thomas, J.D.2    Anconina, J.3
  • 10
    • 0028867393 scopus 로고
    • Dynamic three-dimensional echocardiographic assessment of intracardiac blood flow jets
    • Delabays A, Sugeng L, Pandian NG et al. (1995) Dynamic three-dimensional echocardiographic assessment of intracardiac blood flow jets. Am J Cardiol 76:1053-1058
    • (1995) Am J Cardiol , vol.76 , pp. 1053-1058
    • Delabays, A.1    Sugeng, L.2    Pandian, N.G.3
  • 12
    • 0030875169 scopus 로고    scopus 로고
    • Klappenerkrankungen
    • Globits S (1997) Klappenerkrankungen. Radiologe 37:341-350
    • (1997) Radiologe , vol.37 , pp. 341-350
    • Globits, S.1
  • 15
    • 0030892197 scopus 로고    scopus 로고
    • Segmentation of sequences of echocardiographic images using a simplified 3D active contour model with region-based external forces
    • Kucera D, Martin RW (1997) Segmentation of sequences of echocardiographic images using a simplified 3D active contour model with region-based external forces. Comput Med Imaging Graph 21:1-21
    • (1997) Comput Med Imaging Graph , vol.21 , pp. 1-21
    • Kucera, D.1    Martin, R.W.2
  • 18
    • 0032587720 scopus 로고    scopus 로고
    • Tracking the left ventricle in echocardiographic images by learning heart dynamics
    • Malassiotis S, Strintzis MG (1999) Tracking the left ventricle in echocardiographic images by learning heart dynamics. IEEE Trans Med Imaging 18:282-290
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 282-290
    • Malassiotis, S.1    Strintzis, M.G.2
  • 19
    • 0031150146 scopus 로고    scopus 로고
    • Shape-based tracking of left ventricular wall motion
    • McEachen JC, Duncan JS (1997) Shape-based tracking of left ventricular wall motion. IEEE Trans Med Imaging 16:270-283
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 270-283
    • McEachen, J.C.1    Duncan, J.S.2
  • 21
    • 0032034224 scopus 로고    scopus 로고
    • Segmentation and tracking in echocardiographic sequences: Active contours guided by optical flow estimates
    • Mikic I, Krucinski S, Thomas JD (1998) Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates. IEEE Trans Med Imaging 17:274-284
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 274-284
    • Mikic, I.1    Krucinski, S.2    Thomas, J.D.3
  • 22
    • 0031281755 scopus 로고    scopus 로고
    • Automatic segmentation of intravascular ultrasound images: A texture-based approach
    • Mojsilovic A, Popovic M, Amodaj N, Babic R, Ostojic M (1997) Automatic segmentation of intravascular ultrasound images: a texture-based approach. Ann Biomed Eng 25:1059-1071
    • (1997) Ann Biomed Eng , vol.25 , pp. 1059-1071
    • Mojsilovic, A.1    Popovic, M.2    Amodaj, N.3    Babic, R.4    Ostojic, M.5
  • 23
    • 0028046816 scopus 로고
    • Three-dimensional and four-dimensional echocardiography
    • Ofili EO, Nanda NC (1994) Three-dimensional and four-dimensional echocardiography. Ultrasound Med Biol 20:669-675
    • (1994) Ultrasound Med Biol , vol.20 , pp. 669-675
    • Ofili, E.O.1    Nanda, N.C.2
  • 24
    • 0026069172 scopus 로고
    • A new method for quantification of mitral regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study
    • Recusani F, Bargiggia GS, Yoganathan AP et al. (1991) A new method for quantification of mitral regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study. Circulation 83:594-604
    • (1991) Circulation , vol.83 , pp. 594-604
    • Recusani, F.1    Bargiggia, G.S.2    Yoganathan, A.P.3
  • 26
    • 0028106510 scopus 로고
    • Color Doppler regurgitant jet area for evaluating eccentric mitral regurgitation: An animal study with quantified mitral regurgitation
    • Shiota T, Jones M, Teien D, Yamada I, Passafini A, Knudson O, Sahn DJ (1994) Color Doppler regurgitant jet area for evaluating eccentric mitral regurgitation: an animal study with quantified mitral regurgitation. J Am Coll Cardiol 24:813-819
    • (1994) J Am Coll Cardiol , vol.24 , pp. 813-819
    • Shiota, T.1    Jones, M.2    Teien, D.3    Yamada, I.4    Passafini, A.5    Knudson, O.6    Sahn, D.J.7
  • 27
    • 0343234292 scopus 로고    scopus 로고
    • Automatische Segmentierung von Herz-Kavitäten in mehrdimensionalen Ultraschallaufnahmen
    • Evers H, Glombitza G, Lehmann T, Meinzer HP (Hrsg) Springer, Berlin Heidelberg New York, S 77-81
    • Wolf I, Glombitza G, De Simone R, Meinzer HP (1999) Automatische Segmentierung von Herz-Kavitäten in mehrdimensionalen Ultraschallaufnahmen. In: Evers H, Glombitza G, Lehmann T, Meinzer HP (Hrsg) Bildverarbeitung für die Medizin 1999. Springer, Berlin Heidelberg New York, S 77-81
    • (1999) Bildverarbeitung für die Medizin 1999
    • Wolf, I.1    Glombitza, G.2    De Simone, R.3    Meinzer, H.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.