2
-
-
0024388994
-
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
-
Selvik G. Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand 1989;60 Suppl 232:1-51.
-
(1989)
Acta Orthop Scand
, vol.60
, Issue.SUPPL. 232
, pp. 1-51
-
-
Selvik, G.1
-
3
-
-
0022542239
-
Micromotion in knee arthroplasty: A roentgen stereophotogrammetric analysis of tibial component fixation
-
Ryd L. Micromotion in knee arthroplasty: a roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand 1986;57:Suppl 220.
-
(1986)
Acta Orthop Scand
, vol.57
, Issue.SUPPL. 220
-
-
Ryd, L.1
-
4
-
-
0026559855
-
The influence of metal backing in unicompartmental tibial component fixation: An in vivo roentgen stereophotogrammetric analysis of micromotion
-
Ryd L, Lindstrand A, Stenström A, Selvik G. The influence of metal backing in unicompartmental tibial component fixation: an in vivo roentgen stereophotogrammetric analysis of micromotion. Arch Orthop Trauma Surg 1992;111:148-54.
-
(1992)
Arch Orthop Trauma Surg
, vol.111
, pp. 148-154
-
-
Ryd, L.1
Lindstrand, A.2
Stenström, A.3
Selvik, G.4
-
5
-
-
0025254338
-
The effect of a stem on the tibial component of knee arthroplasty
-
Albrektsson BEJ, Ryd L, Carlsson LV, et al. The effect of a stem on the tibial component of knee arthroplasty. J Bone Joint Surg [Br] 1990;72-B:252-8.
-
(1990)
J Bone Joint Surg [Br]
, vol.72 B
, pp. 252-258
-
-
Albrektsson, B.E.J.1
Ryd, L.2
Carlsson, L.V.3
-
6
-
-
0000902148
-
Increased subsidence of uncemented stemmed Tricon-M knee prostheses: Roentgen stereophotogrammetric analysis of cemented versus uncemented tibial components
-
Nilsson KG, Kärrholm J. Increased subsidence of uncemented stemmed Tricon-M knee prostheses: roentgen stereophotogrammetric analysis of cemented versus uncemented tibial components. Am J Knee Surg 1990;5:174-83.
-
(1990)
Am J Knee Surg
, vol.5
, pp. 174-183
-
-
Nilsson, K.G.1
Kärrholm, J.2
-
7
-
-
0025049407
-
Effects of screws and a sleeve on initial fixation in uncemented total knee tibial components
-
Miura H, Whiteside LA, Easley JC, Amador DD. Effects of screws and a sleeve on initial fixation in uncemented total knee tibial components. Clin Orthop 1990;259:160-8.
-
(1990)
Clin Orthop
, vol.259
, pp. 160-168
-
-
Miura, H.1
Whiteside, L.A.2
Easley, J.C.3
Amador, D.D.4
-
8
-
-
0028039065
-
Four screws for fixation of the tibial component in cementless total knee arthroplasty
-
Whiteside LA. Four screws for fixation of the tibial component in cementless total knee arthroplasty. Clin Orthop 1994;299:72-6.
-
(1994)
Clin Orthop
, vol.299
, pp. 72-76
-
-
Whiteside, L.A.1
-
9
-
-
0031972219
-
Hydroxyapatite augmentation of the porous coating improves fixation of tibial components: A randomised RSA study in 116 patients
-
Önsten I, Nordqvist A, Carlsson ÅS, Besjakov J, Shott S. Hydroxyapatite augmentation of the porous coating improves fixation of tibial components: a randomised RSA study in 116 patients. J Bone Joint Surg [Br] 1998;80-B:417-25.
-
(1998)
J Bone Joint Surg [Br]
, vol.80 B
, pp. 417-425
-
-
Önsten, I.1
Nordqvist, A.2
Carlsson, Å.S.3
Besjakov, J.4
Shott, S.5
-
10
-
-
0025986872
-
Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis
-
Nilsson KG, Kärrholm J, Ekelund L, Magnusson P. Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis. J Arthroplasty 1991;6:265-78.
-
(1991)
J Arthroplasty
, vol.6
, pp. 265-278
-
-
Nilsson, K.G.1
Kärrholm, J.2
Ekelund, L.3
Magnusson, P.4
-
11
-
-
0026577172
-
Proximally cemented versus uncemented Freeman Samuelson knee arthroplasty: A prospective, randomised study
-
Albrektsson BEJ, Carlsson LV, Freeman MAR, Herberts P, Ryd L. Proximally cemented versus uncemented Freeman Samuelson knee arthroplasty: a prospective, randomised study. J Bone Joint Surg [Br] 1992;74-B:233-8.
-
(1992)
J Bone Joint Surg [Br]
, vol.74 B
, pp. 233-238
-
-
Albrektsson, B.E.J.1
Carlsson, L.V.2
Freeman, M.A.R.3
Herberts, P.4
Ryd, L.5
-
12
-
-
0023958615
-
Trabecular hone strength at the knee
-
Hvid I. Trabecular hone strength at the knee. Clin Orthop 1988;227: 210-21.
-
(1988)
Clin Orthop
, vol.227
, pp. 210-221
-
-
Hvid, I.1
-
13
-
-
0026507994
-
Roentgen stereophotogrammetric analysis ot prosthetic fixation in the hip and knee joint
-
Ryd L. Roentgen stereophotogrammetric analysis ot prosthetic fixation in the hip and knee joint. Clin Orthop 1992;276:56-65.
-
(1992)
Clin Orthop
, vol.276
, pp. 56-65
-
-
Ryd, L.1
-
14
-
-
0029056371
-
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
-
Ryd L, Albrektsson BEJ, Carlsson L, et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg [Br] 1995;77-B:377-83.
-
(1995)
J Bone Joint Surg [Br]
, vol.77 B
, pp. 377-383
-
-
Ryd, L.1
Albrektsson, B.E.J.2
Carlsson, L.3
-
15
-
-
0023856359
-
The mechanical stability of various noncemented tibial components
-
Volz RG, Nisbet JK, Lee RW, McMurtry MG. The mechanical stability of various noncemented tibial components. Clin Orthop 1988;226:38-42.
-
(1988)
Clin Orthop
, vol.226
, pp. 38-42
-
-
Volz, R.G.1
Nisbet, J.K.2
Lee, R.W.3
McMurtry, M.G.4
-
16
-
-
0026582767
-
Early migration of prostheses related to long-term survivorship: Comparison of tibial components in knee replacement
-
Grewal R, Rimmer MG, Freeman MAR. Early migration of prostheses related to long-term survivorship: comparison of tibial components in knee replacement. J Bone Joint Surg [Br] 1992;74-B: 239-42.
-
(1992)
J Bone Joint Surg [Br]
, vol.74 B
, pp. 239-242
-
-
Grewal, R.1
Rimmer, M.G.2
Freeman, M.A.R.3
|