메뉴 건너뛰기




Volumn 33, Issue 6, 2000, Pages 765-770

A continuous pure moment loading apparatus for biomechanical testing of multi-segment spine specimens

Author keywords

Continuous loads; Flexibility testing; Loading apparatus; Pure moments; Spine

Indexed keywords

BENDING (DEFORMATION); CYCLIC LOADS; DEGREES OF FREEDOM (MECHANICS); LOAD TESTING; MUSCULOSKELETAL SYSTEM; PHOTOGRAMMETRY;

EID: 0034019608     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(00)00021-X     Document Type: Article
Times cited : (57)

References (21)
  • 1
    • 0029127034 scopus 로고
    • Mechanical testing of the spine. An appraisal of methodology, results, and conclusions
    • Adams M.A. Mechanical testing of the spine. An appraisal of methodology, results, and conclusions. Spine. 20:1995;2151-2156.
    • (1995) Spine , vol.20 , pp. 2151-2156
    • Adams, M.A.1
  • 4
    • 0030038215 scopus 로고    scopus 로고
    • Short-segment pedicle instrumentation. Biomechanical analysis of supplemental hook fixation
    • Chiba M., McLain R.F., Yerby S.A., Moseley T.A., Smith T.S., Benson D.R. Short-segment pedicle instrumentation. Biomechanical analysis of supplemental hook fixation. Spine. 21:1996;288-294.
    • (1996) Spine , vol.21 , pp. 288-294
    • Chiba, M.1    McLain, R.F.2    Yerby, S.A.3    Moseley, T.A.4    Smith, T.S.5    Benson, D.R.6
  • 5
    • 0029803219 scopus 로고    scopus 로고
    • Effects of posture and structure on three-dimensional coupled rotations in the lumbar spine. A biomechanical analysis
    • Cholewicki, J., Crisco, J.J., III, Oxland, T.R., Yamamoto, I., Panjabi, M.M., 1996. Effects of posture and structure on three-dimensional coupled rotations in the lumbar spine. A biomechanical analysis. Spine 21, 2421-2428.
    • (1996) Spine , vol.21 , pp. 2421-2428
    • Cholewicki, J.1    Crisco J.J. III2    Oxland, T.R.3    Yamamoto, I.4    Panjabi, M.M.5
  • 6
    • 0029096617 scopus 로고
    • An apparatus for applying pure nonconstraining moments to spine segments in vitro
    • Crawford N.R., Brantley A.G.U., Dickman C.A., Koeneman E.J. An apparatus for applying pure nonconstraining moments to spine segments in vitro. Spine. 20:1995;2097-2100.
    • (1995) Spine , vol.20 , pp. 2097-2100
    • Crawford, N.R.1    Brantley, A.G.U.2    Dickman, C.A.3    Koeneman, E.J.4
  • 8
    • 0343518956 scopus 로고
    • Assessment of a new load test device for measuring the rigidity of the thoraco-lumbar fixation systems
    • Eggli S., Schlapfer F., Schneider E., Aebi M. Assessment of a new load test device for measuring the rigidity of the thoraco-lumbar fixation systems. Orthopaedic Transactions. 15:1991;371.
    • (1991) Orthopaedic Transactions , vol.15 , pp. 371
    • Eggli, S.1    Schlapfer, F.2    Schneider, E.3    Aebi, M.4
  • 10
    • 0030041382 scopus 로고    scopus 로고
    • The role of spinal instrumentation in augmenting lumbar posterolateral fusion
    • Kotani Y., Cunningham B.W., Cappuccino A., Kaneda K., McAfee P.C. The role of spinal instrumentation in augmenting lumbar posterolateral fusion. Spine. 21:1996;278-287.
    • (1996) Spine , vol.21 , pp. 278-287
    • Kotani, Y.1    Cunningham, B.W.2    Cappuccino, A.3    Kaneda, K.4    McAfee, P.C.5
  • 12
    • 0017362194 scopus 로고
    • Experimental determination of spinal motion segment behavior
    • Panjabi M.M. Experimental determination of spinal motion segment behavior. Orthopaedic Clinics of North America. 8:1977;169-180.
    • (1977) Orthopaedic Clinics of North America , vol.8 , pp. 169-180
    • Panjabi, M.M.1
  • 13
    • 0023723917 scopus 로고
    • Biomechanical evaluation of spinal fixation devices: I. A conceptual framework
    • Panjabi M.M. Biomechanical evaluation of spinal fixation devices. I. A conceptual framework Spine. 13:1988;1129-1134.
    • (1988) Spine , vol.13 , pp. 1129-1134
    • Panjabi, M.M.1
  • 14
    • 0028331360 scopus 로고
    • Lumbar spine instability. A biochemical challenge
    • Panjabi M.M. Lumbar spine instability. A biochemical challenge. Current Orthopaedics. 8:1994;100-105.
    • (1994) Current Orthopaedics , vol.8 , pp. 100-105
    • Panjabi, M.M.1
  • 16
    • 0028793906 scopus 로고
    • Biomechanical properties of threaded inserts for lumbar interbody spinal fusion
    • Tencer A.F., Hampton D., Eddy S. Biomechanical properties of threaded inserts for lumbar interbody spinal fusion. Spine. 20:1995;2408-2414.
    • (1995) Spine , vol.20 , pp. 2408-2414
    • Tencer, A.F.1    Hampton, D.2    Eddy, S.3
  • 18
    • 0028217257 scopus 로고
    • A universal spine tester for in vitro experiments with muscle force simulation
    • Wilke H.J., Claes L., Schmitt H., Wolf S. A universal spine tester for in vitro experiments with muscle force simulation. European Spine Journal. 3:1994;91-97.
    • (1994) European Spine Journal , vol.3 , pp. 91-97
    • Wilke, H.J.1    Claes, L.2    Schmitt, H.3    Wolf, S.4
  • 19
    • 2442713465 scopus 로고
    • Processing of raw kinematic data
    • Wiley, Toronto
    • Winter, D.A., 1979. Processing of raw kinematic data. In: Biomechanics of Human Movement. Wiley, Toronto, pp. 25-39.
    • (1979) In: Biomechanics of Human Movement , pp. 25-39
    • Winter, D.A.1
  • 20
    • 0024819818 scopus 로고
    • Three-dimensional movements of the whole lumbar spine and lumbosacral joint
    • Yamamoto I., Panjabi M.M., Crisco T., Oxland T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine. 14:1989;1256-1260.
    • (1989) Spine , vol.14 , pp. 1256-1260
    • Yamamoto, I.1    Panjabi, M.M.2    Crisco, T.3    Oxland, T.4
  • 21
    • 0028967834 scopus 로고
    • An experimental technique to induce and quantify complex cyclic forces to the lumbar spine
    • Yoganandan N., Cusick J.F., Pintar F.A., Droese K., Voo L. An experimental technique to induce and quantify complex cyclic forces to the lumbar spine. Neurosurgery. 36:1995;956-964.
    • (1995) Neurosurgery , vol.36 , pp. 956-964
    • Yoganandan, N.1    Cusick, J.F.2    Pintar, F.A.3    Droese, K.4    Voo, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.