Performance of three blood glucose meters

Author keywords

Accu Chek Advantage; Blood glucose meters; Error grid analysis; Glucometer Elite; One Touch II; Reference laboratory standard

Indexed keywords

ACCURACY; ADULT; ARTICLE; BLOOD GLUCOSE MONITORING; DEVICE; FEMALE; HUMAN; MALE; MEASUREMENT; PERFORMANCE; PRIORITY JOURNAL; VALIDATION PROCESS;

EID: 0034015449     PISSN: 10600280     EISSN: None     Source Type: Journal    
DOI: 10.1345/aph.19187     Document Type: Article
Times cited : (68)

References (21)
  • 1
    • 85086350585 scopus 로고    scopus 로고
    • American Diabetes Association: Bedside blood glucose monitoring in hospitals (consensus statement)
    • American Diabetes Association: bedside blood glucose monitoring in hospitals (consensus statement). Diabetes Care 1998;21(suppl 1):S78.
    • (1998) Diabetes Care , vol.21 , Issue.SUPPL. 1
  • 2
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long term complications in insulin dependent diabetes mellitus
    • The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long term complications in insulin dependent diabetes mellitus. N Engl J Med 1993;329:977-86.
    • (1993) N Engl J Med , vol.329 , pp. 977-986
  • 3
    • 0028441425 scopus 로고
    • Clinical accuracy of capillary blood glucose monitoring in hospitalized patients with diabetes
    • Bustamante MA, Hennessey JV, Teter ML, Stachler RJ, Warner B. Clinical accuracy of capillary blood glucose monitoring in hospitalized patients with diabetes. Diabetes Educ 1994;20:212-5.
    • (1994) Diabetes Educ , vol.20 , pp. 212-215
    • Bustamante, M.A.1    Hennessey, J.V.2    Teter, M.L.3    Stachler, R.J.4    Warner, B.5
  • 5
    • 0030066052 scopus 로고    scopus 로고
    • American Diabetes Association: Self-monitoring of blood glucose (consensus statement)
    • American Diabetes Association: self-monitoring of blood glucose (consensus statement). Diabetes Care 1996;19(suppl 1):S62-6.
    • (1996) Diabetes Care , vol.19 , Issue.SUPPL. 1
  • 6
    • 0028799855 scopus 로고
    • Advances and strategies for glucose monitoring
    • Chmielewski SA. Advances and strategies for glucose monitoring. Am J Clin Pathol 1995;104(suppl 1):S59-71.
    • (1995) Am J Clin Pathol , vol.104 , Issue.SUPPL. 1
    • Chmielewski, S.A.1
  • 9
    • 85038046171 scopus 로고
    • Tarrytown, NY: Technicon Instruments, November
    • Technicon Chem Systems - Glucose. Tarrytown, NY: Technicon Instruments, November 1990.
    • (1990) Technicon Chem Systems - Glucose
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8:307-10.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0030985974 scopus 로고    scopus 로고
    • Reservations on the use of the error grid analysis for the validation of blood glucose assays
    • Gough DA, Botvinick EL. Reservations on the use of the error grid analysis for the validation of blood glucose assays. Diabetes Care 1997;20: 1034-6.
    • (1997) Diabetes Care , vol.20 , pp. 1034-1036
    • Gough, D.A.1    Botvinick, E.L.2
  • 14
    • 0028000904 scopus 로고
    • The effect of recurrent practice at home on the acceptability of capillary blood glucose readings
    • Kabadi UM, O'Connell KM, Johnson J, Kabadi M. The effect of recurrent practice at home on the acceptability of capillary blood glucose readings. Diabetes Care 1994;17:1110-4.
    • (1994) Diabetes Care , vol.17 , pp. 1110-1114
    • Kabadi, U.M.1    O'Connell, K.M.2    Johnson, J.3    Kabadi, M.4
  • 16
    • 0028537388 scopus 로고
    • Accuracy of blood glucose monitoring for patients: What it is and how to achieve it
    • Fleming DR. Accuracy of blood glucose monitoring for patients: what it is and how to achieve it. Diabetes Educ 1994;20:495-500.
    • (1994) Diabetes Educ , vol.20 , pp. 495-500
    • Fleming, D.R.1
  • 18
    • 0029243058 scopus 로고
    • Monitoring blood glucose meters
    • Rainey PM, Jarlow P. Monitoring blood glucose meters (editorial). Am J Clin Pathol 1995;103:125-6.
    • (1995) Am J Clin Pathol , vol.103 , pp. 125-126
    • Rainey, P.M.1    Jarlow, P.2
  • 19
    • 0003171040 scopus 로고
    • American Diabetes Association: Self-monitoring of blood glucose (consensus statement)
    • American Diabetes Association: self-monitoring of blood glucose (consensus statement). Diabetes Care 1994;17(suppl 1):S83.
    • (1994) Diabetes Care , vol.17 , Issue.SUPPL. 1
  • 20
    • 85038046530 scopus 로고    scopus 로고
    • Indianapolis, IN: Boerhinger Mannheim Corp.
    • Accu-Chek Advantage user's manual. Indianapolis, IN: Boerhinger Mannheim Corp., 1997.
    • (1997) Accu-chek Advantage User's Manual
  • 21
    • 85038046418 scopus 로고    scopus 로고
    • Milpitas, CA: LifeScan, Johnson & Johnson
    • One Touch II user's manual. Milpitas, CA: LifeScan, Johnson & Johnson, 1997.
    • (1997) One Touch II User's Manual


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.