Volumn 25, Issue 1, 2000, Pages 55-61

A retrospective analysis of high resolution computed tomography in the assessment of cochlear implant patients

Author keywords

Cochlea ossification; Cochlear implants; Computed tomography; Radiography of temporal bone

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CHILD; COCHLEA PROSTHESIS; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; HEARING ACUITY; HEARING IMPAIRMENT; HUMAN; MAJOR CLINICAL STUDY; MALE; MENINGITIS; OSSIFICATION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TEMPORAL BONE;

EID: 0034014699     PISSN: 03077772     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2273.2000.00325.x     Document Type: Article
Times cited : (41)

References (35)
  • 2
    • 0026032398 scopus 로고
    • Radiology for cochlear implants
    • 2 Gray R., Evans R., Freer C. et al. (1991) Radiology for cochlear implants. J. Laryngol. Otol. 105, 85-88
    • (1991) J. Laryngol. Otol. , vol.105 , pp. 85-88
    • Gray, R.1    Evans, R.2    Freer, C.3
  • 3
    • 0026576583 scopus 로고
    • Basal turn of the cochlea
    • 3 Phelps P.D. (1992) Basal turn of the cochlea. Br. J. Radiol. 65, 370-374
    • (1992) Br. J. Radiol. , vol.65 , pp. 370-374
    • Phelps, P.D.1
  • 4
    • 0014492802 scopus 로고
    • Histopathology of auditory and vestibular disorders in head trauma
    • 4 Ward P. (1969) Histopathology of auditory and vestibular disorders in head trauma. Ann. Otorhinolaryngol. 78, 227-238
    • (1969) Ann. Otorhinolaryngol. , vol.78 , pp. 227-238
    • Ward, P.1
  • 6
    • 0026448999 scopus 로고
    • Cochlear implants for congenital deformities
    • 6 Phelps P.D. (1992) Cochlear implants for congenital deformities. J Laryngol. Otol. 106, 967-970
    • (1992) J Laryngol. Otol. , vol.106 , pp. 967-970
    • Phelps, P.D.1
  • 7
    • 0024517540 scopus 로고
    • Temporal bone computed tomography in the pre-operative evaluation for cochlear implantation
    • 7 Mueller D.P., Dolan K. & Gantz B. (1989) Temporal bone computed tomography in the pre-operative evaluation for cochlear implantation. Ann. Otorhinolaryngol. 98, 346-349
    • (1989) Ann. Otorhinolaryngol. , vol.98 , pp. 346-349
    • Mueller, D.P.1    Dolan, K.2    Gantz, B.3
  • 9
    • 0030067578 scopus 로고    scopus 로고
    • Accuracy of high-resolution computed tomography in cochlear implantation
    • 9 Langham A.W. & Quigley S.M. (1996) Accuracy of high-resolution computed tomography in cochlear implantation. Otolaryngol. Head Neck Surg. 114, 38-43
    • (1996) Otolaryngol. Head Neck Surg. , vol.114 , pp. 38-43
    • Langham, A.W.1    Quigley, S.M.2
  • 10
    • 0020675074 scopus 로고
    • A systemic technique for comprehensive evaluation of the temporal bone by computed tomography
    • 10 Chakeres D.W. & Spiegel P.K. (1983) A systemic technique for comprehensive evaluation of the temporal bone by computed tomography. Radiology 146, 97-106
    • (1983) Radiology , vol.146 , pp. 97-106
    • Chakeres, D.W.1    Spiegel, P.K.2
  • 11
    • 0023214321 scopus 로고
    • Cochlear patency problems in cochlear implantation
    • 11 Jackler R.K., Luxford W.M., Schindler R.N. et al. (1987) Cochlear patency problems in cochlear implantation. Laryngoscope 97, 801-805
    • (1987) Laryngoscope , vol.97 , pp. 801-805
    • Jackler, R.K.1    Luxford, W.M.2    Schindler, R.N.3
  • 12
    • 0028021196 scopus 로고
    • High-resolution computed tomography in evaluation of cochlear patency in implant candidates: A comparison with surgical findings
    • 12 Frau G.N., Luxford W.M., Lo W.W. et al. (1994) High-resolution computed tomography in evaluation of cochlear patency in implant candidates: a comparison with surgical findings. J. Laryngol. Otol. 108, 743-748
    • (1994) J. Laryngol. Otol. , vol.108 , pp. 743-748
    • Frau, G.N.1    Luxford, W.M.2    Lo, W.W.3
  • 13
    • 0029093296 scopus 로고
    • Aetiology of hearing loss and cochlear computed tomography: Findings in preimplant assessment
    • 13 Woolford T.J., Roberts G.R., Hartley C. et al. (1995) Aetiology of hearing loss and cochlear computed tomography: findings in preimplant assessment. Ann. Otol. Rhinol. Laryngol. 166, 201-206
    • (1995) Ann. Otol. Rhinol. Laryngol. , vol.166 , pp. 201-206
    • Woolford, T.J.1    Roberts, G.R.2    Hartley, C.3
  • 14
    • 0028815350 scopus 로고
    • Role of modern imaging technology in the implementation of paediatric cochlear implants
    • 14 Silberman B., Garabedian E.N., Denoyelle F. et al. (1995) Role of modern imaging technology in the implementation of paediatric cochlear implants. Ann. Otol. Rhinol. Laryngol. 104, 42-46
    • (1995) Ann. Otol. Rhinol. Laryngol. , vol.104 , pp. 42-46
    • Silberman, B.1    Garabedian, E.N.2    Denoyelle, F.3
  • 15
    • 0023215301 scopus 로고
    • Cochlear implant candidates: Assessment with CT and MR imaging
    • 15 Harnsberger H., Dart D., Parkin J. et al. (1987) Cochlear implant candidates: assessment with CT and MR imaging. Radiology 164, 53-57
    • (1987) Radiology , vol.164 , pp. 53-57
    • Harnsberger, H.1    Dart, D.2    Parkin, J.3
  • 17
    • 0022365041 scopus 로고
    • Labyrinthine ossification: Aetiologies and CT findings
    • 17 Swartz J., Mandell D., Faerber E. et al. (1985) Labyrinthine ossification: aetiologies and CT findings. Radiology 157, 395-398
    • (1985) Radiology , vol.157 , pp. 395-398
    • Swartz, J.1    Mandell, D.2    Faerber, E.3
  • 18
    • 0023337976 scopus 로고
    • Workshop: Surgical anatomy and radiographic imaging of cochlear implant surgery
    • 18 Valvasorri G.E. (1987) Workshop: surgical anatomy and radiographic imaging of cochlear implant surgery. Am. J. Otol. 8, 195-200
    • (1987) Am. J. Otol. , vol.8 , pp. 195-200
    • Valvasorri, G.E.1
  • 19
    • 0025175777 scopus 로고
    • Labyrinthine ossification after meningitis: Its implications for cochlear implantation
    • 19 Novak M.A., Fifer R.C., Barkmeier J.C. et al. (1990) Labyrinthine ossification after meningitis: its implications for cochlear implantation. Otolaryngol. Head Neck Surg. 103, 351-356
    • (1990) Otolaryngol. Head Neck Surg. , vol.103 , pp. 351-356
    • Novak, M.A.1    Fifer, R.C.2    Barkmeier, J.C.3
  • 20
    • 0014117848 scopus 로고
    • Pathology of suppurative labyrinthitis
    • 20 Paparella M. & Suguria S. (1967) Pathology of suppurative labyrinthitis. Ann. Otorhinolaryngol. 76, 554-586
    • (1967) Ann. Otorhinolaryngol. , vol.76 , pp. 554-586
    • Paparella, M.1    Suguria, S.2
  • 21
    • 0025726372 scopus 로고    scopus 로고
    • Labyrinthitis ossificans: Histopathologic consideration for cochlear implantation
    • 21 Green J.D.J., Marion M.S. & Hinojosa R. (1998) Labyrinthitis ossificans: histopathologic consideration for cochlear implantation. Otolaryngol. Head Neck Surg. 104, 320-325
    • (1998) Otolaryngol. Head Neck Surg. , vol.104 , pp. 320-325
    • Green, J.D.J.1    Marion, M.S.2    Hinojosa, R.3
  • 22
  • 23
    • 0026345674 scopus 로고
    • A multipedigree linkage study of X-linked deafness linkage to Xq13-q12 and evidence fof heterogenity
    • 23 Reardon W., Middleton-Price H.R., Sandkuijl L. et al. (1991) A multipedigree linkage study of X-linked deafness linkage to Xq13-q12 and evidence fof heterogenity. Genomics 11, 885-894
    • (1991) Genomics , vol.11 , pp. 885-894
    • Reardon, W.1    Middleton-Price, H.R.2    Sandkuijl, L.3
  • 24
    • 0013637764 scopus 로고
    • Normal CT scanning of the temporal bone
    • Springer-Verlag. London, Berlin
    • 24 Phelps P.D. & Lloyd G.A.S. (1990) Normal CT scanning of the temporal bone. In Diagnostic Imaging of the Ear 2nd edn, pp. 9 19. Springer-Verlag. London, Berlin
    • (1990) Diagnostic Imaging of the Ear 2nd Edn , pp. 919
    • Phelps, P.D.1    Lloyd, G.A.S.2
  • 25
    • 0030883807 scopus 로고    scopus 로고
    • Cochlear implants in children with congenital inner ear malformations
    • 25 Luntz M., Balkany T., Hodges A.V. et al. (1997) Cochlear implants in children with congenital inner ear malformations. Arch. Otolaryngol. Head Neck Surg. 123, 974-977
    • (1997) Arch. Otolaryngol. Head Neck Surg. , vol.123 , pp. 974-977
    • Luntz, M.1    Balkany, T.2    Hodges, A.V.3
  • 26
    • 0028280248 scopus 로고
    • Temporal bone imaging for cochlear implantation
    • 26 Seidman D.A., Chute P.M. & Parisier S. (1994) Temporal Bone Imaging for Cochlear Implantation. Laryngoscope 104, 562-565
    • (1994) Laryngoscope , vol.104 , pp. 562-565
    • Seidman, D.A.1    Chute, P.M.2    Parisier, S.3
  • 27
    • 0025340525 scopus 로고
    • Computed tomography: How accurate a predictor for cochlear implantation
    • 27 Wiet R., Pyle G., O'Connor C. et al. (1990) Computed tomography: how accurate a predictor for cochlear implantation. Laryngoscope 100, 687-692
    • (1990) Laryngoscope , vol.100 , pp. 687-692
    • Wiet, R.1    Pyle, G.2    O'Connor, C.3
  • 29
    • 0018870171 scopus 로고
    • Labyrinthine ossification and cochlear implants
    • 29 Ibrahim R.A.A. & Linthcum F.H.J. (1980) Labyrinthine ossification and cochlear implants. Arch Otolaryngol 106, 111-113
    • (1980) Arch Otolaryngol , vol.106 , pp. 111-113
    • Ibrahim, R.A.A.1    Linthcum, F.H.J.2
  • 30
    • 0024230974 scopus 로고
    • Magnetic-resonance imaging and high resolution CT in cochlear implant candidates
    • 30 Laszig R., Terwey B., Ratimer R.D. et al. (1988) Magnetic-resonance imaging and high resolution CT in cochlear implant candidates. Scand Audiol 17 (Suppl.), 197-200
    • (1988) Scand Audiol , vol.17 , Issue.SUPPL. , pp. 197-200
    • Laszig, R.1    Terwey, B.2    Ratimer, R.D.3
  • 31
    • 0027722071 scopus 로고
    • Paediatric cochlear implantation: How reliable is computed tomography in assessing cochlear patency?
    • 31 Bath A.P., O'Donoghue G.M., Holland I.M. et al. (1993) Paediatric cochlear implantation: how reliable is computed tomography in assessing cochlear patency? Clin. Otolaryngol. 18, 475-479
    • (1993) Clin. Otolaryngol. , vol.18 , pp. 475-479
    • Bath, A.P.1    O'Donoghue, G.M.2    Holland, I.M.3
  • 32
    • 0023698142 scopus 로고
    • Computed tomography and magnetic resonance imaging of the inner ear
    • 32 Jackler R.K. & Dillon W.P. (1988) Computed tomography and magnetic resonance imaging of the inner ear. Otolaryngol. Head Neck Surg. 99, 494-504
    • (1988) Otolaryngol. Head Neck Surg. , vol.99 , pp. 494-504
    • Jackler, R.K.1    Dillon, W.P.2
  • 33
    • 0031821489 scopus 로고    scopus 로고
    • Cochlear implant failure due to unexpected absence of the eighth nerve: A cautionary tale
    • 33 Gray R.F., Ray J., Baguley D.M. et al. (1998) Cochlear implant failure due to unexpected absence of the eighth nerve: a cautionary tale. J. Laryngol. Otol. 112, 646-649
    • (1998) J. Laryngol. Otol. , vol.112 , pp. 646-649
    • Gray, R.F.1    Ray, J.2    Baguley, D.M.3
  • 34
    • 0030815317 scopus 로고    scopus 로고
    • Sub-millimeter imaging and reconstruction of the inner ear
    • 34 Dahm M.C., Mack M.G., Tykocinski M. et al. (1997) Sub-millimeter imaging and reconstruction of the inner ear. Am. J. Otol. 18, S54-S56
    • (1997) Am. J. Otol. , vol.18
    • Dahm, M.C.1    Mack, M.G.2    Tykocinski, M.3
  • 35
    • 0029119446 scopus 로고
    • Assessment of intracochlear ossification by three-dimensional reconstruction of computerised scans
    • 35 Pyman B.C., Seldon H.L., O'Sullivan R. et al. (1995) Assessment of intracochlear ossification by three-dimensional reconstruction of computerised scans. Ann. Otol. Rhinol. Laryngol. 166(Suppl.), 79-83
    • (1995) Ann. Otol. Rhinol. Laryngol. , vol.166 , Issue.SUPPL. , pp. 79-83
    • Pyman, B.C.1    Seldon, H.L.2    O'Sullivan, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.