메뉴 건너뛰기




Volumn 13, Issue 1, 2000, Pages 37-42

Simultaneous detection of changes in perfusion and BOLD contrast

Author keywords

BOLD contrast; Cerebral blood flow; fMRI; Human brain mapping; Perfusion; Quantification

Indexed keywords

ADULT; ARTICLE; BLOOD OXYGENATION; BRAIN BLOOD FLOW; BRAIN MAPPING; BRAIN PERFUSION; CLINICAL ARTICLE; CONTRAST ENHANCEMENT; FEMALE; HUMAN; IMAGE ANALYSIS; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; VISUAL STIMULATION;

EID: 0034010652     PISSN: 09523480     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-1492(200002)13:1<37::AID-NBM611>3.0.CO;2-0     Document Type: Article
Times cited : (12)

References (29)
  • 1
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc. Natl Acad. Sci. USA 1990; 87: 9868-9872.
    • (1990) Proc. Natl Acad. Sci. USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 2
    • 0030797751 scopus 로고    scopus 로고
    • Magnetic resonance imaging of human brain function. Principles, practicalities, and possibilities
    • Bandettini PA, Wong EC. Magnetic resonance imaging of human brain function. Principles, practicalities, and possibilities. Neurosurg. Clin. of N. Am. 1997; 8: 345-371.
    • (1997) Neurosurg. Clin. of N. Am. , vol.8 , pp. 345-371
    • Bandettini, P.A.1    Wong, E.C.2
  • 3
    • 0030793271 scopus 로고    scopus 로고
    • Comparison of blood oxygenation and cerebral blood flow effects in fMRI: Estimation of relative oxygen consumption change
    • Kim SG, Ugurbil K. Comparison of blood oxygenation and cerebral blood flow effects in fMRI: estimation of relative oxygen consumption change. Magn. Reson. Med. 1997; 38: 59-65.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 59-65
    • Kim, S.G.1    Ugurbil, K.2
  • 4
    • 0030719382 scopus 로고    scopus 로고
    • Multi-slice perfusion based functional MRI using the FAIR technique - Comparison of CBF and BOLD effects
    • Kim SG, Tsekos NV, Ashe J. Multi-slice perfusion based functional MRI using the FAIR technique - comparison of CBF and BOLD effects. NMR Biomed. 1997; 10: 191-196.
    • (1997) NMR Biomed. , vol.10 , pp. 191-196
    • Kim, S.G.1    Tsekos, N.V.2    Ashe, J.3
  • 8
    • 0342971825 scopus 로고    scopus 로고
    • Comparing chages in BOLD contrast and perfusion induced by either visual stimulation or hypercapnia: Identification of areas of increased oxygen consumption
    • Schwarzbauer C, Heinke W. Comparing chages in BOLD contrast and perfusion induced by either visual stimulation or hypercapnia: identification of areas of increased oxygen consumption. Magma 1997; 5: (Suppl.), 13.
    • (1997) Magma , vol.5 , Issue.SUPPL. , pp. 13
    • Schwarzbauer, C.1    Heinke, W.2
  • 10
    • 0032997945 scopus 로고    scopus 로고
    • Investigating the dependence of BOLD contrast on oxidative metabolism
    • Schwarzbauer C, Heinke W. Investigating the dependence of BOLD contrast on oxidative metabolism. Magn. Reson. Med. 1999; 41: 537-543.
    • (1999) Magn. Reson. Med. , vol.41 , pp. 537-543
    • Schwarzbauer, C.1    Heinke, W.2
  • 12
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn. Reson. Med. 1995; 34: 293-301.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 13
    • 0030012099 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice
    • Schwarzbauer C, Morrissey SP, Haase A. Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice. Magn. Reson. Med. 1996; 35: 540-546.
    • (1996) Magn. Reson. Med. , vol.35 , pp. 540-546
    • Schwarzbauer, C.1    Morrissey, S.P.2    Haase, A.3
  • 14
    • 36149042452 scopus 로고
    • Multiplanar image formation using NMR spin echoes
    • Mansfield P. Multiplanar image formation using NMR spin echoes J. Phys. C 1977; 10: L55-L58.
    • (1977) J. Phys. C , vol.10
    • Mansfield, P.1
  • 16
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • Ye FQ, Mattay VS, Jezzard P, Frank JA, Weinberger DR, McLaughlin AC. Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magn. Reson. Med. 1997; 37: 226-235.
    • (1997) Magn. Reson. Med. , vol.37 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3    Frank, J.A.4    Weinberger, D.R.5    McLaughlin, A.C.6
  • 18
    • 0028387214 scopus 로고
    • Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: A comparative study at 1.5 T
    • Bandettini PA, Wong EC, Jesmanowicz A, Hinks RS, Hyde JS. Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T. NMR. Biomed. 1994; 7: 12-20.
    • (1994) NMR. Biomed. , vol.7 , pp. 12-20
    • Bandettini, P.A.1    Wong, E.C.2    Jesmanowicz, A.3    Hinks, R.S.4    Hyde, J.S.5
  • 19
    • 0031842664 scopus 로고    scopus 로고
    • Signal undershoots following visual stimulation: A comparison of gradient-and spin-echo BOLD sequences
    • Jones RA, Schirmer T, Lipinski B, Elbel GK, Auer DP. Signal undershoots following visual stimulation: a comparison of gradient-and spin-echo BOLD sequences. Magn. Reson. Med. 1998; 40: 112-118.
    • (1998) Magn. Reson. Med. , vol.40 , pp. 112-118
    • Jones, R.A.1    Schirmer, T.2    Lipinski, B.3    Elbel, G.K.4    Auer, D.P.5
  • 21
    • 48549111126 scopus 로고
    • Highly selective π/2 and π pulse generation
    • Silver MS, Joseph RI, Hoult DI. Highly selective π/2 and π pulse generation. J. Magn. Reson. 1984; 59: 347-351.
    • (1984) J. Magn. Reson. , vol.59 , pp. 347-351
    • Silver, M.S.1    Joseph, R.I.2    Hoult, D.I.3
  • 22
    • 0030175198 scopus 로고    scopus 로고
    • Afni - Software for analysis and visualization of functional magnetic resonance neuroimages
    • Cox RW. Afni - software for analysis and visualization of functional magnetic resonance neuroimages Comput. Biomed. Res. 1996; 29: 162-173.
    • (1996) Comput. Biomed. Res. , vol.29 , pp. 162-173
    • Cox, R.W.1
  • 23
    • 0027288454 scopus 로고
    • Processing strategies for time-course data sets in functional MRI of the human brain
    • Bandettini PA, Jesmanowicz A, Wong EC, Hyde JS. Processing strategies for time-course data sets in functional MRI of the human brain. Magn. Reson. Med. 1993; 30: 161-173.
    • (1993) Magn. Reson. Med. , vol.30 , pp. 161-173
    • Bandettini, P.A.1    Jesmanowicz, A.2    Wong, E.C.3    Hyde, J.S.4
  • 24
    • 0021991039 scopus 로고
    • What is the correct value for the brain-blood partition coefficient for water?
    • Herscovitch P, Raichle ME. What is the correct value for the brain-blood partition coefficient for water? J. Cereb. Blood Flow Metab. 1985; 5: 65-69.
    • (1985) J. Cereb. Blood Flow Metab. , vol.5 , pp. 65-69
    • Herscovitch, P.1    Raichle, M.E.2
  • 26
    • 0021030757 scopus 로고
    • Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis
    • Herscovitch P, Markham J, Raichle ME. Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis. J. Nucl. Med. 1983; 24: 782-789.
    • (1983) J. Nucl. Med. , vol.24 , pp. 782-789
    • Herscovitch, P.1    Markham, J.2    Raichle, M.E.3
  • 27
    • 0021084822 scopus 로고
    • Brain blood flow measured with intravenous H2(15)O. II. Implementation and validation
    • Raichle ME, Martin WR, Herscovitch P, Mintun MA, Markham J. Brain blood flow measured with intravenous H2(15)O. II. Implementation and validation. J. Nucl. Med. 1983; 24: 790-798.
    • (1983) J. Nucl. Med. , vol.24 , pp. 790-798
    • Raichle, M.E.1    Martin, W.R.2    Herscovitch, P.3    Mintun, M.A.4    Markham, J.5
  • 28
    • 0021134681 scopus 로고
    • A noninvasive approach to quantitative functional brain mapping with H2 (15)O and positron emission tomography
    • Fox PT, Mintun MA, Raichle ME, Herscovitch P. A noninvasive approach to quantitative functional brain mapping with H2 (15)O and positron emission tomography. J. Cereb. Blood. Flow. Metab. 1984; 4: 329-333.
    • (1984) J. Cereb. Blood. Flow. Metab. , vol.4 , pp. 329-333
    • Fox, P.T.1    Mintun, M.A.2    Raichle, M.E.3    Herscovitch, P.4
  • 29
    • 0024577053 scopus 로고
    • A highly accurate method of localizing regions of neuronal activation in the human brain with positron emission tomography
    • Mintun MA, Fox PT, Raichle ME. A highly accurate method of localizing regions of neuronal activation in the human brain with positron emission tomography. J. Cereb. Blood Flow Metab. 1989; 9: 96-103.
    • (1989) J. Cereb. Blood Flow Metab. , vol.9 , pp. 96-103
    • Mintun, M.A.1    Fox, P.T.2    Raichle, M.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.