메뉴 건너뛰기




Volumn 17, Issue 2, 2000, Pages 159-163

Diagnostic catheterization and balloon sizing of atrial septal defects by echocardiographic guidance without fluoroscopy

Author keywords

Atrial septal defect; Balloon sizing; Congenital heart disease; Echocardiography; Transcatheter closure

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CATHETERIZATION; CLINICAL ARTICLE; CONGENITAL HEART DISEASE; DIAGNOSTIC VALUE; ECHOCARDIOGRAPHY; ELECTROCARDIOGRAM; FLUOROSCOPY; HEART ATRIUM SEPTUM DEFECT; HUMAN; INFANT; OXIMETRY; PRIORITY JOURNAL; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 0034006824     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2000.tb01117.x     Document Type: Article
Times cited : (14)

References (9)
  • 1
    • 0021833247 scopus 로고
    • Surgical repair of uncomplicated atrial septal defect without "routine" preoperative cardiac catheterization
    • 1. Shub C, Tajik AJ, Seward JB, et al: Surgical repair of uncomplicated atrial septal defect without "routine" preoperative cardiac catheterization. J Am Coll Cardiol 1985;6:49-54.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 49-54
    • Shub, C.1    Tajik, A.J.2    Seward, J.B.3
  • 2
    • 0029119657 scopus 로고
    • Seven-year experience of noninvasive preoperative diagnostics in children with congenital heart defects: Comprehensive analysis of 2,788 consecutive patients
    • 2. Marek J, Skovranek J, Hucin B, et al: Seven-year experience of noninvasive preoperative diagnostics in children with congenital heart defects: Comprehensive analysis of 2,788 consecutive patients. Cardiology 1995;86: 488-495.
    • (1995) Cardiology , vol.86 , pp. 488-495
    • Marek, J.1    Skovranek, J.2    Hucin, B.3
  • 3
    • 0032054829 scopus 로고    scopus 로고
    • Closure of atrial septal defects with the Amplatzer occlusion device: Preliminary results
    • 3. Thanopoulos BD, Laskari CV, Tsaousis GS, et al: Closure of atrial septal defects with the Amplatzer occlusion device: Preliminary results. J Am Coll Cardiol 1998;31:1110-1116.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 1110-1116
    • Thanopoulos, B.D.1    Laskari, C.V.2    Tsaousis, G.S.3
  • 4
    • 0031829081 scopus 로고    scopus 로고
    • Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (Cardio-SEAL)
    • 4. Kaulitz R, Paul T, Hausdorf G: Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (Cardio-SEAL). Heart 1998;80:54-59.
    • (1998) Heart , vol.80 , pp. 54-59
    • Kaulitz, R.1    Paul, T.2    Hausdorf, G.3
  • 5
    • 0033193572 scopus 로고    scopus 로고
    • Transcatheter closure as standard therapy of most interatrial defects
    • 5. Berger F, Ewert P, Bjornstad P, et al: Transcatheter closure as standard therapy of most interatrial defects. Cardiol Young 1999;9:468-473.
    • (1999) Cardiol Young , vol.9 , pp. 468-473
    • Berger, F.1    Ewert, P.2    Bjornstad, P.3
  • 6
    • 0033091340 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects under echocardiographic guidance without x-ray - Initial experiences
    • 6. Ewert P, Daehnert I, Berger F, et al: Transcatheter closure of atrial septal defects under echocardiographic guidance without x-ray - Initial experiences. Cardiol Young 1999;9:136-140.
    • (1999) Cardiol Young , vol.9 , pp. 136-140
    • Ewert, P.1    Daehnert, I.2    Berger, F.3
  • 7
    • 0023902190 scopus 로고
    • Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect
    • 7. Dittmann H, Jacksch R, Voelker W, et al: Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect. J Am Coll Cardiol 1988;11: 338-342.
    • (1988) J Am Coll Cardiol , vol.11 , pp. 338-342
    • Dittmann, H.1    Jacksch, R.2    Voelker, W.3
  • 8
    • 0026750429 scopus 로고
    • Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion
    • 8. Rao PS, Langhough R, Beekman RH, et al: Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion. Am Heart J 1992;124:172-175.
    • (1992) Am Heart J , vol.124 , pp. 172-175
    • Rao, P.S.1    Langhough, R.2    Beekman, R.H.3
  • 9
    • 0028865419 scopus 로고
    • Imaging and sizing of atrial septal defects by magnetic resonance
    • 9. Holmvang G, Palacios IF, Vlahakes GJ, et al: Imaging and sizing of atrial septal defects by magnetic resonance. Circulation 1995;92:3473-3480.
    • (1995) Circulation , vol.92 , pp. 3473-3480
    • Holmvang, G.1    Palacios, I.F.2    Vlahakes, G.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.