메뉴 건너뛰기




Volumn 15, Issue SUPPL. 1, 2000, Pages 43-48

On-line haemodiafiltration versus low-flux haemodialysis. A prospective randomized study

Author keywords

[No Author keywords available]

Indexed keywords

BETA 2 MICROGLOBULIN; ERYTHROPOIETIN; POLYSULFONE; PREALBUMIN; SERUM ALBUMIN; TRANSFERRIN;

EID: 0034004781     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.ndt.a027963     Document Type: Conference Paper
Times cited : (171)

References (15)
  • 1
    • 0029814092 scopus 로고    scopus 로고
    • The dose of hemodialysis and patient mortality
    • Held P, Port F, Wolfe R, et al. The dose of hemodialysis and patient mortality. Kidney Int 1996; 50: 550-556
    • (1996) Kidney Int , vol.50 , pp. 550-556
    • Held, P.1    Port, F.2    Wolfe, R.3
  • 2
    • 0027964630 scopus 로고
    • Quantification of dialysis
    • Cheung A. Quantification of dialysis. Blood Purif 1994; 12: 42-53
    • (1994) Blood Purif , vol.12 , pp. 42-53
    • Cheung, A.1
  • 3
    • 0029053991 scopus 로고
    • Protein adsorption by artificial membrane materials under filtration conditions
    • Birk HW, Kistner A, Wizemann V, Schütterte G. Protein adsorption by artificial membrane materials under filtration conditions. Artif Organs 1995; 19: 411-415
    • (1995) Artif Organs , vol.19 , pp. 411-415
    • Birk, H.W.1    Kistner, A.2    Wizemann, V.3    Schütterte, G.4
  • 4
    • 0027688501 scopus 로고
    • Second generation logarithmic estimates of single pool variable Kt/V: An analysis of error
    • Daugirdas J. Second generation logarithmic estimates of single pool variable Kt/V: an analysis of error. J Am Soc Nephrol 1993; 4: 1205-1213
    • (1993) J Am Soc Nephrol , vol.4 , pp. 1205-1213
    • Daugirdas, J.1
  • 5
    • 0028790558 scopus 로고
    • The dilemma of assessing volume state - The use and the limitation of a clinical score
    • Wizemann V, Schilling M. The dilemma of assessing volume state - the use and the limitation of a clinical score. Nephrol Dial Transplant 1995; 10: 2114-2117
    • (1995) Nephrol Dial Transplant , vol.10 , pp. 2114-2117
    • Wizemann, V.1    Schilling, M.2
  • 6
    • 0026521445 scopus 로고
    • Comparison of hemodialysis and hemodiafiltration: A long-term longitudinal study
    • Kerr P, Argilis A, Flavier J-L, Canaud B, Mion C. Comparison of hemodialysis and hemodiafiltration: A long-term longitudinal study. Kidney Int 1992; 41: 1035-1040
    • (1992) Kidney Int , vol.41 , pp. 1035-1040
    • Kerr, P.1    Argilis, A.2    Flavier, J.-L.3    Canaud, B.4    Mion, C.5
  • 7
    • 10244255046 scopus 로고    scopus 로고
    • Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters
    • Locatelli F, Mastrangelo F, Redaelli B, Ronco C, Marcelli D, LaGreca D, Orlandini G. Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. Kidney Int 1996; 50: 1293-1302
    • (1996) Kidney Int , vol.50 , pp. 1293-1302
    • Locatelli, F.1    Mastrangelo, F.2    Redaelli, B.3    Ronco, C.4    Marcelli, D.5    LaGreca, D.6    Orlandini, G.7
  • 8
    • 0029911432 scopus 로고    scopus 로고
    • High-flux hemodialysis postpones clinical manifestation of dialysis related amyloidosis
    • Küchle C, Fricke H, Held E, Schiffl H. High-flux hemodialysis postpones clinical manifestation of dialysis related amyloidosis. Am J Nephrol 1996; 16: 484-488
    • (1996) Am J Nephrol , vol.16 , pp. 484-488
    • Küchle, C.1    Fricke, H.2    Held, E.3    Schiffl, H.4
  • 9
    • 0025300351 scopus 로고
    • Death risk in hemodialysis patients: The predictive value of commonly measured variables and on evaluation of death rate differences between facilities
    • Lowry E, New H. Death risk in hemodialysis patients: the predictive value of commonly measured variables and on evaluation of death rate differences between facilities. Am J Kidney Dis 1990; 15: 458-482
    • (1990) Am J Kidney Dis , vol.15 , pp. 458-482
    • Lowry, E.1    New, H.2
  • 10
    • 0030657419 scopus 로고    scopus 로고
    • Malnutrion is bad, but how can one detect malnutrion
    • Druml W. Malnutrion is bad, but how can one detect malnutrion. Nephrol Dial Transplant 1997; 12: 2225-2227
    • (1997) Nephrol Dial Transplant , vol.12 , pp. 2225-2227
    • Druml, W.1
  • 11
    • 0029149357 scopus 로고
    • Mechanism of hypalbuminemia in hemodialysis patients
    • Kaysen G, Rathore V, Shearer G, Depner T. Mechanism of hypalbuminemia in hemodialysis patients. Kidney Int 1995; 48: 510-516
    • (1995) Kidney Int , vol.48 , pp. 510-516
    • Kaysen, G.1    Rathore, V.2    Shearer, G.3    Depner, T.4
  • 12
    • 0025368086 scopus 로고
    • Effects of a modified hemodiafiltration method on low-molecular weight proteins
    • Wizemann V, Birk H-W, Techert F. Effects of a modified hemodiafiltration method on low-molecular weight proteins. Blood Purif 1990; 8: 45-51
    • (1990) Blood Purif , vol.8 , pp. 45-51
    • Wizemann, V.1    Birk, H.-W.2    Techert, F.3
  • 14
    • 0030021933 scopus 로고    scopus 로고
    • The intensity of hemodialysis and the response to erythropoietin in patients with end-stage renal disease
    • Ifudo O, Feldmann J, Friedmann E. The intensity of hemodialysis and the response to erythropoietin in patients with end-stage renal disease. N Engl J Med 1996; 334: 420-425
    • (1996) N Engl J Med , vol.334 , pp. 420-425
    • Ifudo, O.1    Feldmann, J.2    Friedmann, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.