메뉴 건너뛰기




Volumn 31, Issue 4, 2000, Pages 794-797

Successful percutaneous endovascular treatment of a ruptured popliteal artery aneurysm

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ALPHA 1 ANTITRYPSIN DEFICIENCY; ANEURYSM RUPTURE; ARTERIOGRAPHY; ARTERY GRAFT; ARTICLE; CASE REPORT; DOPPLER ECHOGRAPHY; ENDOVASCULAR SURGERY; HUMAN; LIMB SALVAGE; LUNG EMPHYSEMA; MALE; POLITEF IMPLANT; POPLITEAL ARTERY; PRIORITY JOURNAL; STENT;

EID: 0034002510     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1067/mva.2000.102329     Document Type: Article
Times cited : (47)

References (12)
  • 2
    • 0028329057 scopus 로고
    • Transfemoral endoluminal stented graft repair of a popliteal artery aneurysm
    • Marin ML, Veith FJ, Panetta TF, et al. Transfemoral endoluminal stented graft repair of a popliteal artery aneurysm. J Vasc Surg 1994;19:754-7.
    • (1994) J Vasc Surg , vol.19 , pp. 754-757
    • Marin, M.L.1    Veith, F.J.2    Panetta, T.F.3
  • 3
    • 0031700116 scopus 로고    scopus 로고
    • Initial experiences with percutaneous repair of popliteal artery lesions using a new PTFE stent-graft
    • Burger T, Meyer F, Tautenhahn J, et al. Initial experiences with percutaneous repair of popliteal artery lesions using a new PTFE stent-graft. J Endovasc Surg 1998;5:365-72.
    • (1998) J Endovasc Surg , vol.5 , pp. 365-372
    • Burger, T.1    Meyer, F.2    Tautenhahn, J.3
  • 4
    • 0029886728 scopus 로고    scopus 로고
    • Stent graft for popliteal artery aneurysms. Six cases with Cragg Endo-Pro System 1 Mintec
    • Marcade JP. Stent graft for popliteal artery aneurysms. Six cases with Cragg Endo-Pro System 1 Mintec. J Cardiovasc Surg 1996;37:41-4.
    • (1996) J Cardiovasc Surg , vol.37 , pp. 41-44
    • Marcade, J.P.1
  • 5
    • 0031646966 scopus 로고    scopus 로고
    • Successful endoluminal repair of a popliteal artery aneurysm using the Wallgraft endoprosthesis
    • Kudelko PE II, Alfaro-Franco C, Diethrich EB, Krajcer Z. Successful endoluminal repair of a popliteal artery aneurysm using the Wallgraft endoprosthesis. J Endovasc Surg 1998; 5:373-7.
    • (1998) J Endovasc Surg , vol.5 , pp. 373-377
    • Kudelko II, P.E.1    Alfaro-Franco, C.2    Diethrich, E.B.3    Krajcer, Z.4
  • 6
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-9.
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 9
    • 0030862139 scopus 로고    scopus 로고
    • Acute rupture of the descending thoracic aorta: Repair with use of endovascular stent-grafts
    • Semba CP, Kato N, Kee ST, et al. Acute rupture of the descending thoracic aorta: Repair with use of endovascular stent-grafts. J Vasc Interv Radiol 1997;8:337-42.
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 337-342
    • Semba, C.P.1    Kato, N.2    Kee, S.T.3
  • 10
    • 0031051481 scopus 로고    scopus 로고
    • Rupture as the exceptional complication of popliteal artery aneurysm
    • Gawenda M, Sorgatz S, Walter M, Erasmi H. Rupture as the exceptional complication of popliteal artery aneurysm. Eur J Surg 1997;163:69-71.
    • (1997) Eur J Surg , vol.163 , pp. 69-71
    • Gawenda, M.1    Sorgatz, S.2    Walter, M.3    Erasmi, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.