메뉴 건너뛰기




Volumn 84, Issue 3, 2000, Pages 354-357

Effects of the sitting position on the distribution of blood volume in patients undergoing neurosurgical procedures

Author keywords

Blood, volume; Measurement techniques, indicator dilution; Position, effects; Position, sitting; Surgery, neurological

Indexed keywords

ADULT; AGED; ANESTHESIA INDUCTION; ARTERIAL PRESSURE; ARTICLE; BLOOD VOLUME; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DYE DILUTION CURVE; FEMALE; HEART INDEX; HEART STROKE VOLUME; HUMAN; LUNG BLOOD VOLUME; MALE; NEUROSURGERY; PRIORITY JOURNAL; SITTING; SUPINE POSITION;

EID: 0034000369     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.bja.a013439     Document Type: Article
Times cited : (85)

References (16)
  • 2
    • 0027935271 scopus 로고
    • The sitting position in neurosurgical anaesthesia: A survey of British practice in 1991
    • Elton RJ, Howell SC. The sitting position in neurosurgical anaesthesia: a survey of British practice in 1991. Br J Anaesth 1994; 73: 247-8
    • (1994) Br J Anaesth , vol.73 , pp. 247-248
    • Elton, R.J.1    Howell, S.C.2
  • 3
    • 0023690475 scopus 로고
    • Outcome following posterior fossa craniectomy in patients in the sitting or horizontal position
    • Black S, Ockert DB, Oliver WC, Cucciara RK. Outcome following posterior fossa craniectomy in patients in the sitting or horizontal position. Anesthesiology 1980; 69: 49-56
    • (1980) Anesthesiology , vol.69 , pp. 49-56
    • Black, S.1    Ockert, D.B.2    Oliver, W.C.3    Cucciara, R.K.4
  • 5
    • 0022569975 scopus 로고
    • Comparison of surgical and anesthetic complcations in neurosurgical patients experiencing venous air embolism in the sitting position
    • Young ML, Smith DS, Murtagh F, et al. Comparison of surgical and anesthetic complcations in neurosurgical patients experiencing venous air embolism in the sitting position. Neurosurgery 1986; 18: 157-61
    • (1986) Neurosurgery , vol.18 , pp. 157-161
    • Young, M.L.1    Smith, D.S.2    Murtagh, F.3
  • 6
    • 0018722314 scopus 로고
    • Cardiorespiratory effects of the sitting position in neurosurgery
    • Dalrymple DG, MacGowan SW, MacLeod GF. Cardiorespiratory effects of the sitting position in neurosurgery. Br J Anaesth 1979; 51: 1079-82
    • (1979) Br J Anaesth , vol.51 , pp. 1079-1082
    • Dalrymple, D.G.1    MacGowan, S.W.2    MacLeod, G.F.3
  • 7
    • 0020636490 scopus 로고
    • Cardiovascular responses in the seated position - Impact of four anesthetic techniques
    • Marshall WK, Bedford RF, Miller ED. Cardiovascular responses in the seated position - impact of four anesthetic techniques. Anesth Analg 1983; 62: 648-53
    • (1983) Anesth Analg , vol.62 , pp. 648-653
    • Marshall, W.K.1    Bedford, R.F.2    Miller, E.D.3
  • 8
    • 0028334544 scopus 로고
    • Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery
    • Hoeft A, Schorn B, Weyland A, et al. Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery. Anesthesiology 1994; 81: 76-86
    • (1994) Anesthesiology , vol.81 , pp. 76-86
    • Hoeft, A.1    Schorn, B.2    Weyland, A.3
  • 9
    • 0027493989 scopus 로고
    • Thoracic intravascular and extravascular fluid volumes in cardiac surgical patients
    • Hachenberg T, Tenling A, Rothen HU, et al. Thoracic intravascular and extravascular fluid volumes in cardiac surgical patients. Anesthesiology 1993; 79: 976-84
    • (1993) Anesthesiology , vol.79 , pp. 976-984
    • Hachenberg, T.1    Tenling, A.2    Rothen, H.U.3
  • 10
    • 0029077603 scopus 로고
    • Accuracy and reproducibility of the measurement of actively circulating blood volume with an integrated fiberoptic monitoring system
    • Kisch H, Leucht S, Lichtwarck AM, Pfeiffer UJ. Accuracy and reproducibility of the measurement of actively circulating blood volume with an integrated fiberoptic monitoring system. Crit Care Med 1995; 23: 885-93
    • (1995) Crit Care Med , vol.23 , pp. 885-893
    • Kisch, H.1    Leucht, S.2    Lichtwarck, A.M.3    Pfeiffer, U.J.4
  • 11
    • 0000606319 scopus 로고
    • Theoretical basis of indicator dilution methods for measuring flow and volume
    • Zierler K. Theoretical basis of indicator dilution methods for measuring flow and volume. Circ Res 1962; 10: 393-407
    • (1962) Circ Res , vol.10 , pp. 393-407
    • Zierler, K.1
  • 12
    • 0030475788 scopus 로고    scopus 로고
    • Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload
    • Lichtwarck-Aschoff M, Beale R, Pfeiffer UJ. Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload. J Crit Care 1996; 11: 180-8
    • (1996) J Crit Care , vol.11 , pp. 180-188
    • Lichtwarck-Aschoff, M.1    Beale, R.2    Pfeiffer, U.J.3
  • 13
    • 0026689496 scopus 로고
    • Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation
    • Lichtwarck-Aschoff M, Zeravik J, Pfeiffer UJ. Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med 1992; 18: 142-7
    • (1992) Intensive Care Med , vol.18 , pp. 142-147
    • Lichtwarck-Aschoff, M.1    Zeravik, J.2    Pfeiffer, U.J.3
  • 14
    • 0015966092 scopus 로고
    • Effective compliance of the total vascular bed and the intrathoracic compartment derived from changes in central venous pressure induced by volume changes in man
    • Echt M, Düweling J, Gauer OH, Lange L. Effective compliance of the total vascular bed and the intrathoracic compartment derived from changes in central venous pressure induced by volume changes in man. Circ Res 1973; 34: 61-8
    • (1973) Circ Res , vol.34 , pp. 61-68
    • Echt, M.1    Düweling, J.2    Gauer, O.H.3    Lange, L.4
  • 15
    • 0023005545 scopus 로고
    • The low pressure system: The integrated function of veins
    • Arndt JO. The low pressure system: the integrated function of veins. Eur J Anaesthesiol 1986; 3: 343-70
    • (1986) Eur J Anaesthesiol , vol.3 , pp. 343-370
    • Arndt, J.O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.