Volumn 46, Issue 4, 2000, Pages 1071-1075

Assessment of large single-fraction, low-energy X-ray dose with radiochromic film

Author keywords

In vivo dosimetry; Low energy; Radiochromic film; Single fraction irradiation; X rays

Indexed keywords

ACCURACY; ARTICLE; CALIBRATION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DOSIMETRY; HUMAN; PRIORITY JOURNAL; RADIATION DOSE; RADIATION ENERGY; TECHNIQUE; X RAY FILM;

EID: 0033999541     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(99)00465-4     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 0029086205 scopus 로고
    • Considerations for superficial photon dosimetry
    • Stern R., Kubo H. Considerations for superficial photon dosimetry. Med Phys. 22:1995;1469-1470.
    • (1995) Med Phys , vol.22 , pp. 1469-1470
    • Stern, R.1    Kubo, H.2
  • 2
    • 0031812771 scopus 로고    scopus 로고
    • Superficial and orthovoltage beam dosimetry
    • Podgorsak E., Gosselin M., Evans M. Superficial and orthovoltage beam dosimetry. Med Phys. 25:1998;1206-1211.
    • (1998) Med Phys , vol.25 , pp. 1206-1211
    • Podgorsak, E.1    Gosselin, M.2    Evans, M.3
  • 3
    • 0029376751 scopus 로고
    • Verification of surface dose on patients undergoing low to medium energy x-ray therapy
    • Ferguson S., Ostwald P., Kron T., Denham J. Verification of surface dose on patients undergoing low to medium energy x-ray therapy. Med Dosim. 20:1995;161-165.
    • (1995) Med Dosim , vol.20 , pp. 161-165
    • Ferguson, S.1    Ostwald, P.2    Kron, T.3    Denham, J.4
  • 4
    • 0030293626 scopus 로고    scopus 로고
    • TLD extrapolation for skin dose determination in-vivo
    • Kron T., Butson M., Hunt F., et al. TLD extrapolation for skin dose determination in-vivo. Radiother Oncol. 41:1996;119-123.
    • (1996) Radiother Oncol , vol.41 , pp. 119-123
    • Kron, T.1    Butson, M.2    Hunt, F.3
  • 5
    • 0027172666 scopus 로고
    • X-ray surface dose measurements using TLD extrapolation
    • Kron T., Elliott A., Wong T., et al. X-ray surface dose measurements using TLD extrapolation. Med Phys. 20:1993;703-711.
    • (1993) Med Phys , vol.20 , pp. 703-711
    • Kron, T.1    Elliott, A.2    Wong, T.3
  • 7
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two-dimensional dosimetry
    • Zhu Y., Kirov A., Mishra A., et al. Quantitative evaluation of radiochromic film response for two-dimensional dosimetry. Med Phys. 24:1997;223-231.
    • (1997) Med Phys , vol.24 , pp. 223-231
    • Zhu, Y.1    Kirov, A.2    Mishra, A.3
  • 8
    • 0029832035 scopus 로고    scopus 로고
    • Dosimetric characteristics of an improved radiochromic film
    • Meigooni A., Sanders M., Ibbott G., et al. Dosimetric characteristics of an improved radiochromic film. Med Phys. 23:1996;1883-1888.
    • (1996) Med Phys , vol.23 , pp. 1883-1888
    • Meigooni, A.1    Sanders, M.2    Ibbott, G.3
  • 9
    • 0031215187 scopus 로고    scopus 로고
    • Conversion of an infrared densitometer for radiochromic film analysis
    • Carolan M., Butson M., Herrmann K., et al. Conversion of an infrared densitometer for radiochromic film analysis. Aust Phys Eng Sci Med. 20:1997;183-185.
    • (1997) Aust Phys Eng Sci Med , vol.20 , pp. 183-185
    • Carolan, M.1    Butson, M.2    Herrmann, K.3
  • 10
    • 0031466420 scopus 로고    scopus 로고
    • Gafchromic MD-55: Investigated as a precision dosimeter
    • Klassen N., Zwan L., Cygler J. Gafchromic MD-55 Investigated as a precision dosimeter . Med Phys. 24:1997;1924-1934.
    • (1997) Med Phys , vol.24 , pp. 1924-1934
    • Klassen, N.1    Zwan, L.2    Cygler, J.3
  • 12
    • 0001326870 scopus 로고
    • Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams
    • McLaughlin W., Yun-Dong C., Soares C., et al. Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams. Nucl Inst Meth Phys Res. A302:1991;165-176.
    • (1991) Nucl Inst Meth Phys Res , vol.302 , pp. 165-176
    • McLaughlin, W.1    Yun-Dong, C.2    Soares, C.3
  • 13
    • 0031669679 scopus 로고    scopus 로고
    • Measurement of off axis and peripheral skin dose using radiochromic film
    • Butson M., Yu P.K.N., Metcalfe P. Measurement of off axis and peripheral skin dose using radiochromic film. Phys Med Biol. 43:1998;2647-2650.
    • (1998) Phys Med Biol , vol.43 , pp. 2647-2650
    • Butson, M.1    Yu, P.K.N.2    Metcalfe, P.3